Anthoney Shawn Deaton
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Anthoney Shawn Deaton has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Emiel DenHartog
Wilson College of Textiles, North Carolina State University, Raleigh, NC 27606, USA
3 shared publications - Huipu Gao
Textile Protection and Comfort Center, North Carolina State University, USA
3 shared publications Kyle Watson
Textile Protection and Comfort Center, North Carolina State University, USA
3 shared publicationsRoger L. Barker
Textile Protection and Comfort Center, North Carolina State University, Raleigh, NC, USA
3 shared publications- Xiaomeng Fang
Department of Textile Engineering, Chemistry and Science, North Carolina State University, 1020 Main Campus Drive, Raleigh, NC 27606, USA
3 shared publications - Roger L. Barker
Textile Protection and Comfort Center, North Carolina State University, Raleigh, USA
2 shared publications
Latest Publications
- 4 May 2022
- Published by Taylor & Francis in The Journal of the Textile Institute
- Vol. 114 (5) , 737-745
Using a physiological manikin to evaluate the effect of foam thermal reinforcement in firefighter turnout construction on heat strain
Firefighter turnout gear is a significant contributor to firefighter heat stress. This study uses a physiological manikin procedure to show how adding impermeable foam reinforcement in a firefighter suit construction can detrimentally affect firefighter heat strain. It shows that singular reliance on the THL (total heat loss) requirement called for by the NFPA (National Fire Protection Association) 1971 performance standard for firefighter gear leaves a critical gap in information needed to evaluate the heat strain contribution of reinforced turnout suit constructions. This is because THL test only measures heat loss through flat swatches of fabric used in the main body of the turnout suit construction. It does not account for the additional insulation and moisture vapor resistance of reinforcement or the overwhelming effects of garment air layers. This study demonstrates instrumented manikin testing procedures can supply the missing information in laboratory based heat strain performance testing of firefighter turnout suits.
- 4 May 2022
- Published by Taylor & Francis in The Journal of the Textile Institute
- Vol. 114 (5) , 737-745
Using a physiological manikin to evaluate the effect of foam thermal reinforcement in firefighter turnout construction on heat strain
Firefighter turnout gear is a significant contributor to firefighter heat stress. This study uses a physiological manikin procedure to show how adding impermeable foam reinforcement in a firefighter suit construction can detrimentally affect firefighter heat strain. It shows that singular reliance on the THL (total heat loss) requirement called for by the NFPA (National Fire Protection Association) 1971 performance standard for firefighter gear leaves a critical gap in information needed to evaluate the heat strain contribution of reinforced turnout suit constructions. This is because THL test only measures heat loss through flat swatches of fabric used in the main body of the turnout suit construction. It does not account for the additional insulation and moisture vapor resistance of reinforcement or the overwhelming effects of garment air layers. This study demonstrates instrumented manikin testing procedures can supply the missing information in laboratory based heat strain performance testing of firefighter turnout suits.
- Open Access
- 2 May 2022
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 29 (2) , 562-572
Relationship between heat loss indexes and physiological indicators of turnout-related heat strain in mild and hot environments
A validated physiological manikin method was used to qualify environmentally dependent correlations between firefighter turnout total heat loss (THL) and intrinsic evaporative resistance (Ref) heat strain indexes and core temperature rise in stressful work conducted in mild (25 °C, 65% relative humidity [RH]) and hot (35 °C, 40% RH; 40 °C, 28% RH) conditions. Five turnout suit constructions representing a wide range of breathability were selected. The observed correlations between measured material heat loss and core temperature showed that the THL heat strain index accurately forecast thermal burden in mild environments (35 °C). They showed that the THL index did not predict heat strain in hot work environments. The findings of this study support incorporating both the Ref and THL heat strain indexes as dual metrics for characterizing the heat strain performance of turnout clothing fabrics.
- 2 May 2022
- Published by Taylor & Francis in International Journal of Occupational Safety and Ergonomics
- Vol. 29 (2) , 562-572
Open AccessRelationship between heat loss indexes and physiological indicators of turnout-related heat strain in mild and hot environments
A validated physiological manikin method was used to qualify environmentally dependent correlations between firefighter turnout total heat loss (THL) and intrinsic evaporative resistance (Ref) heat strain indexes and core temperature rise in stressful work conducted in mild (25 °C, 65% relative humidity [RH]) and hot (35 °C, 40% RH; 40 °C, 28% RH) conditions. Five turnout suit constructions representing a wide range of breathability were selected. The observed correlations between measured material heat loss and core temperature showed that the THL heat strain index accurately forecast thermal burden in mild environments (35 °C). They showed that the THL index did not predict heat strain in hot work environments. The findings of this study support incorporating both the Ref and THL heat strain indexes as dual metrics for characterizing the heat strain performance of turnout clothing fabrics.
- 22 July 2021
- Published by SAGE Publications in Textile Research Journal
- Vol. 92 (1-2) , 219-231
Effects of environmental temperature and humidity on evaporative heat loss through firefighter suit materials made with semi-permeable and microporous moisture barriers
The goal of this research was to understand how firefighter protective suits perform in different operational environments. This study used a sweating guarded hotplate to examine the effect of environmental temperature (20–45°C) and relative humidity (25–85% RH) on evaporative heat loss through firefighter turnout materials. Four firefighter turnout composites containing three different bi-component (semi-permeable) and one microporous moisture barriers were selected. The results showed that the evaporative resistance of microporous moisture barrier systems was independent of environmental testing conditions. However, absorbed moisture strongly affected evaporative heat loss through semi-permeable moisture barriers coated with a layer of nonporous hydrophilic polymer. Moisture absorption in mild environment (20–25°C) tests, or when testing at high humidity (>85% RH), significantly increased water vapor transmission in semi-permeable turnout systems. It was also found that environmental conditions used in the total heat loss (THL) test (25°C and 65% RH) produced moisture condensation in bi-component barrier systems, making them appear more breathable than could be expected when worn in hotter environments. Regression models successfully qualified the relationships between moisture uptake levels in semi-permeable barrier systems and evaporative resistance and THL. These findings reveal the limitations in relying on THL, the heat strain index currently called for by the NFPA 1971 Standard for Structural Firefighter personal protective equipment, and supports the need to measure turnout evaporative resistance at 35°C (Ret), in addition to THL at 25°C.
- 22 July 2021
- Published by SAGE Publications in Textile Research Journal
- Vol. 92 (1-2) , 219-231
Effects of environmental temperature and humidity on evaporative heat loss through firefighter suit materials made with semi-permeable and microporous moisture barriers
The goal of this research was to understand how firefighter protective suits perform in different operational environments. This study used a sweating guarded hotplate to examine the effect of environmental temperature (20–45°C) and relative humidity (25–85% RH) on evaporative heat loss through firefighter turnout materials. Four firefighter turnout composites containing three different bi-component (semi-permeable) and one microporous moisture barriers were selected. The results showed that the evaporative resistance of microporous moisture barrier systems was independent of environmental testing conditions. However, absorbed moisture strongly affected evaporative heat loss through semi-permeable moisture barriers coated with a layer of nonporous hydrophilic polymer. Moisture absorption in mild environment (20–25°C) tests, or when testing at high humidity (>85% RH), significantly increased water vapor transmission in semi-permeable turnout systems. It was also found that environmental conditions used in the total heat loss (THL) test (25°C and 65% RH) produced moisture condensation in bi-component barrier systems, making them appear more breathable than could be expected when worn in hotter environments. Regression models successfully qualified the relationships between moisture uptake levels in semi-permeable barrier systems and evaporative resistance and THL. These findings reveal the limitations in relying on THL, the heat strain index currently called for by the NFPA 1971 Standard for Structural Firefighter personal protective equipment, and supports the need to measure turnout evaporative resistance at 35°C (Ret), in addition to THL at 25°C.
- 30 September 2020
- Published by ASTM International
- Vol. 11, 222-236
Effectiveness of Using a Thermal Sweating Manikin Coupled with a Thermoregulation Model to Predict Human Physiological Response to Different Firefighter Turnout Suits
Manikins have been used for almost 100 years to help understand the properties of clothing materials and garments. Data from sweating manikins also have been used within thermoregulation computer models to estimate the physiological responses of humans. In recent years, the development of the ManikinPC system has incorporated a thermoregulation model into a thermal sweating manikin system to provide a real-time analysis of predicted physiological response. This paper describes an experimental study that demonstrates the utility of this manikin–model system to predict the effects of three composite materials used in firefighter suits on human physiological response. This study addresses this question: Can ManikinPC emulate the physiological response of a controlled wear trial using three different sets of firefighter turnout gear in one environmental condition? The average core temperature, skin temperature, and sweat loss from human subjects are compared with the predicted values generated from the manikin coupled with the model. Results indicate similar trends and ranking of the three suits. The data revealed slightly higher predictive responses from the manikin–model system compared with the collected human data.
- 30 September 2020
- Published by ASTM International
- Vol. 11, 222-236
Effectiveness of Using a Thermal Sweating Manikin Coupled with a Thermoregulation Model to Predict Human Physiological Response to Different Firefighter Turnout Suits
Manikins have been used for almost 100 years to help understand the properties of clothing materials and garments. Data from sweating manikins also have been used within thermoregulation computer models to estimate the physiological responses of humans. In recent years, the development of the ManikinPC system has incorporated a thermoregulation model into a thermal sweating manikin system to provide a real-time analysis of predicted physiological response. This paper describes an experimental study that demonstrates the utility of this manikin–model system to predict the effects of three composite materials used in firefighter suits on human physiological response. This study addresses this question: Can ManikinPC emulate the physiological response of a controlled wear trial using three different sets of firefighter turnout gear in one environmental condition? The average core temperature, skin temperature, and sweat loss from human subjects are compared with the predicted values generated from the manikin coupled with the model. Results indicate similar trends and ranking of the three suits. The data revealed slightly higher predictive responses from the manikin–model system compared with the collected human data.
- 1 September 2020
- Published by ASTM International
- p. 204-221
Effects of Total Heat Loss versus Evaporative Resistance of Firefighter Garments in a Physiological Heat Strain Trial
- 1 September 2020
- Published by ASTM International
- p. 204-221
Effects of Total Heat Loss versus Evaporative Resistance of Firefighter Garments in a Physiological Heat Strain Trial