Markus B. Blatz
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Markus B. Blatz has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Stefan Holst
Department of Prosthodontics, Friedrich Alexander University Erlangen-Nuremberg, Erlangen, Germany
7 shared publications - Avishai Sadan
Department of Comprehensive Care, Case School of Dental Medicine, Case Western Reserve University, Cleveland, Ohio, USA
6 shared publications - Fusun Ozer
Department of Preventive and Restorative Sciences, University of Pennsylvania School of Dental Medicine, 240 South 40th Street, Philadelphia, PA, United States
6 shared publications - Michael Bergler
Department of Prosthodontics, Erlangen University Hospital, Erlangen, Germany
4 shared publications Gerard Chiche
3 shared publicationsNajeed Saleh
3 shared publications
Latest Publications
- 28 February 2014
- p. 2-8
The current state of adhesive dentistry: a guide for clinical practice.
Adhesive dentistry is key to minimally invasive, esthetic, and tooth-preserving dental restorations. These are typically realized by bonding various restorative materials, such as composite resins, ceramics, or even metal alloys, to tooth structures or other materials with composite resin luting agents. For optimal bond strengths and long-lasting clinical success, however, these material and tooth substrates require their respective pretreatment steps, based on their natures and compositions. Today, dental adhesion is used in almost all dental specialties. This article summarizes key aspects and guidelines for clinical success with adhesive dentistry and summarizes information presented at the 5th International Congress on Adhesive Dentistry.
- 28 February 2014
- p. 2-8
The current state of adhesive dentistry: a guide for clinical practice.
Adhesive dentistry is key to minimally invasive, esthetic, and tooth-preserving dental restorations. These are typically realized by bonding various restorative materials, such as composite resins, ceramics, or even metal alloys, to tooth structures or other materials with composite resin luting agents. For optimal bond strengths and long-lasting clinical success, however, these material and tooth substrates require their respective pretreatment steps, based on their natures and compositions. Today, dental adhesion is used in almost all dental specialties. This article summarizes key aspects and guidelines for clinical success with adhesive dentistry and summarizes information presented at the 5th International Congress on Adhesive Dentistry.
- 1 February 2014
- Vol. 16 (1) , 7-14
Microtensile Bond Strength to Enamel Affected by Hypoplastic Amelogenesis Imperfecta
This study compared the microtensile bond strengths (μTBS) of two different self-etching (SE) and etchand- rinse (ER) adhesive systems to enamel affected by hypoplastic amelogenesis imperfecta (HPAI) and analyzed the enamel etching patterns created by the two adhesive systems using scanning electron microscopy (SEM). Sixteen extracted HPAI-affected molars were used for the bond strength tests and 2 molars were examined under SEM for etching patterns. The control groups consisted of 12 healthy third molars for μTBS tests and two molars for SEM. Mesial and distal surfaces of the teeth were slightly ground flat. The adhesive systems and composite resin were applied to the flat enamel surfaces according to the manufacturers' instructions. The tooth slabs containing composite resin material on their mesial and distal surfaces were cut in the mesio-distal direction with a slow-speed diamond saw. The slabs were cut again to obtain square, 1-mm-thick sticks. Finally, each stick was divided into halves and placed in the μTBS tester. Bond strength tests were performed at a speed of 0.5 mm/min. Data were analyzed with two-way ANOVA and Tukey's tests. There was no significant difference between the bond strength values of ER and SE adhesives (p > 0.05). However, significant differences were found between HPAI and control groups (p < 0.05). HPAI-affected enamel surfaces exhibited mild intra- and inter-prismatic enamel etching patterns after orthophosphoric acid application, while conditioning of HPAI-affected enamel with SE primer created a slightly rough and grooved surface. SE and ER adhesive systems provide similar bond strengths to HPAI-affected enamel surfaces.
- 1 February 2014
- Vol. 16 (1) , 7-14
Microtensile Bond Strength to Enamel Affected by Hypoplastic Amelogenesis Imperfecta
This study compared the microtensile bond strengths (μTBS) of two different self-etching (SE) and etchand- rinse (ER) adhesive systems to enamel affected by hypoplastic amelogenesis imperfecta (HPAI) and analyzed the enamel etching patterns created by the two adhesive systems using scanning electron microscopy (SEM). Sixteen extracted HPAI-affected molars were used for the bond strength tests and 2 molars were examined under SEM for etching patterns. The control groups consisted of 12 healthy third molars for μTBS tests and two molars for SEM. Mesial and distal surfaces of the teeth were slightly ground flat. The adhesive systems and composite resin were applied to the flat enamel surfaces according to the manufacturers' instructions. The tooth slabs containing composite resin material on their mesial and distal surfaces were cut in the mesio-distal direction with a slow-speed diamond saw. The slabs were cut again to obtain square, 1-mm-thick sticks. Finally, each stick was divided into halves and placed in the μTBS tester. Bond strength tests were performed at a speed of 0.5 mm/min. Data were analyzed with two-way ANOVA and Tukey's tests. There was no significant difference between the bond strength values of ER and SE adhesives (p > 0.05). However, significant differences were found between HPAI and control groups (p < 0.05). HPAI-affected enamel surfaces exhibited mild intra- and inter-prismatic enamel etching patterns after orthophosphoric acid application, while conditioning of HPAI-affected enamel with SE primer created a slightly rough and grooved surface. SE and ER adhesive systems provide similar bond strengths to HPAI-affected enamel surfaces.
- 1 January 2014
- Vol. 45 (1) , 31-38
A retrospective survey on long-term survival of posterior zirconia and porcelain-fused-to-metal crowns in private practice
This retrospective survey assessed the clinical survival of zirconia-based crowns (PFZ) and conventional porcelain- fused-to-metal (PFM) crowns on posterior teeth in private practice. A print survey of 13 private practitioners was conducted to assess the long-term survival of previously placed full-coverage crowns. The practitioners reported a total of 2,182 premolar (n = 881) and molar (n = 1,301) full-coverage single crowns, 1,102 PFZ and 1,080 PFM, fabricated by one dental laboratory (Cusp, Boston) and followed over 7.4 years. All post-cementation complications (eg, porcelain fractures and chippings) were recorded as failures. In the PFZ group, one veneering porcelain (CZR, Kuraray Noritake) was used in combination with three coping systems (Lava, 3M ESPE; Procera, Nobelbiocare; Katana, Kuraray Noritake). Kaplan-Meier survival analysis was used for statistical analyses. The probability of survival of posterior crowns investigated over the period of study (7.4 years) was 99.3% for PFM and 99.2% for PFZ restorations. There was no statistically significant difference (P = .614) between PFZ and PFM groups. In the PFZ group, probability of survival was 97.7% for Lava, 100% for Procera, and 99.5% for Katana. There were no statistically significant differences (P = .34) between the three PFZ systems or the location of the crowns (premolar or molar; P = .454). PFZ crowns fabricated with CZR and three commercial zirconia coping systems revealed excellent long-term success rates. Survival times and survival probabilities of posterior PFZ crowns did not differ from PFM crowns and were independent of type of coping system and location (molar or premolar teeth).
- 1 January 2014
- Vol. 45 (1) , 31-38
A retrospective survey on long-term survival of posterior zirconia and porcelain-fused-to-metal crowns in private practice
This retrospective survey assessed the clinical survival of zirconia-based crowns (PFZ) and conventional porcelain- fused-to-metal (PFM) crowns on posterior teeth in private practice. A print survey of 13 private practitioners was conducted to assess the long-term survival of previously placed full-coverage crowns. The practitioners reported a total of 2,182 premolar (n = 881) and molar (n = 1,301) full-coverage single crowns, 1,102 PFZ and 1,080 PFM, fabricated by one dental laboratory (Cusp, Boston) and followed over 7.4 years. All post-cementation complications (eg, porcelain fractures and chippings) were recorded as failures. In the PFZ group, one veneering porcelain (CZR, Kuraray Noritake) was used in combination with three coping systems (Lava, 3M ESPE; Procera, Nobelbiocare; Katana, Kuraray Noritake). Kaplan-Meier survival analysis was used for statistical analyses. The probability of survival of posterior crowns investigated over the period of study (7.4 years) was 99.3% for PFM and 99.2% for PFZ restorations. There was no statistically significant difference (P = .614) between PFZ and PFM groups. In the PFZ group, probability of survival was 97.7% for Lava, 100% for Procera, and 99.5% for Katana. There were no statistically significant differences (P = .34) between the three PFZ systems or the location of the crowns (premolar or molar; P = .454). PFZ crowns fabricated with CZR and three commercial zirconia coping systems revealed excellent long-term success rates. Survival times and survival probabilities of posterior PFZ crowns did not differ from PFM crowns and were independent of type of coping system and location (molar or premolar teeth).
- 1 January 2013
- Vol. 34 (1) , 12
Self-etch and etch-and-rinse adhesive systems in clinical dentistry.
Current adhesive systems follow either an "etch-and-rinse" or "self-etch" approach, which differ in how they interact with natural tooth structures. Etch-and-rinse systems comprise phosphoric acid to pretreat the dental hard tissues before rinsing and subsequent application of an adhesive. Self-etch adhesives contain acidic monomers, which etch and prime the tooth simultaneously. Etch-and-rinse adhesives are offered as two- or three-step systems, depending on whether primer and bonding are separate or combined in a single bottle. Similarly, self-etch adhesives are available as one- or two-step systems. Both etch-and-rinse and self-etch systems form a hybrid layer as a result of resins impregnating the porous enamel or dentin. Despite current trends toward fewer and simpler clinical application steps, one-step dentin bonding systems exhibit bonding agent lower bond strengths and seem less predictable than multi-step etch-and-rinse and self-etch systems. The varying evidence available today suggests that the choice between etch-and-rinse and self-etch systems is often a matter of personal preference. In general, however, phosphoric acid creates a more pronounced and retentive etching pattern in enamel. Therefore, etch-and-rinse bonding systems are often preferred for indirect restorations and when large areas of enamel are still present. Conversely, self-etch adhesives provide superior and more predictable bond strength to dentin and are, consequently, recommended for direct composite resin restorations, especially when predominantly supported by dentin.
- 1 January 2013
- Vol. 34 (1) , 12
Self-etch and etch-and-rinse adhesive systems in clinical dentistry.
Current adhesive systems follow either an "etch-and-rinse" or "self-etch" approach, which differ in how they interact with natural tooth structures. Etch-and-rinse systems comprise phosphoric acid to pretreat the dental hard tissues before rinsing and subsequent application of an adhesive. Self-etch adhesives contain acidic monomers, which etch and prime the tooth simultaneously. Etch-and-rinse adhesives are offered as two- or three-step systems, depending on whether primer and bonding are separate or combined in a single bottle. Similarly, self-etch adhesives are available as one- or two-step systems. Both etch-and-rinse and self-etch systems form a hybrid layer as a result of resins impregnating the porous enamel or dentin. Despite current trends toward fewer and simpler clinical application steps, one-step dentin bonding systems exhibit bonding agent lower bond strengths and seem less predictable than multi-step etch-and-rinse and self-etch systems. The varying evidence available today suggests that the choice between etch-and-rinse and self-etch systems is often a matter of personal preference. In general, however, phosphoric acid creates a more pronounced and retentive etching pattern in enamel. Therefore, etch-and-rinse bonding systems are often preferred for indirect restorations and when large areas of enamel are still present. Conversely, self-etch adhesives provide superior and more predictable bond strength to dentin and are, consequently, recommended for direct composite resin restorations, especially when predominantly supported by dentin.
- 1 November 2012
- Vol. 33 (10) , 776-81
Clinical application of a new self-adhesive resin cement for zirconium-oxide ceramic crowns.
- 1 November 2012
- Vol. 33 (10) , 776-81
Clinical application of a new self-adhesive resin cement for zirconium-oxide ceramic crowns.
- 1 September 2012
- Published by Elsevier in Journal of Evidence-Based Dental Practice
- Vol. 12 (3) , 229-230
Laser Therapy may be Better than Topical Desensitizing Agents for Treating Dentin Hypersensitivity
- 1 September 2012
- Published by Elsevier in Journal of Evidence-Based Dental Practice
- Vol. 12 (3) , 229-230
Laser Therapy may be Better than Topical Desensitizing Agents for Treating Dentin Hypersensitivity
- 1 June 2012
- Vol. 14 (3) , 223-227
Influence of Operator Experience on In Vitro Bond Strength of Dentin Adhesives
To examine the influence of operator experience level on shear bond strength (SBS) of a self-etching adhesive (Clearfil SE Bond [CSE], Kuraray) and an etch-and-rinse adhesive (Single Bond [SB], 3M ESPE). Flat dentin surfaces were created on 120 extracted human third molars. Bonding agents and composite resin were applied and light cured according to manufacturers' directions (n = 15). Four operators with different levels of experience in operative dentistry performed the same specimen preparation steps independently: group 1: specialist in operative dentistry; group 2: post-graduate student; group 3: undergraduate dental student; group 4: private general practitioner. Specimens were stored in distilled water for 24 h at 37°C before SBS testing. Statistical analyses were carried out with Mann-Whitney U- and Kruskall-Wallis tests. For CSE, mean SBS and standard deviations were: (1) 54.4 ± 15.6(a), (2) 55.3 ± 7.6(a), (3) 49.4 ± 10.5(ab), (4) 41.6 ± 13.1(b). For SB, they were: (1) 28.6 ± 10.3(c), (2) 32.7 ± 11.2(c), (3) 17.5 ± 5.6(d), (4) 24.4 ± 9.5(cd). Groups with the same superscript letters are not significantly different. CSE showed higher bond strengths than SB in all groups (p < 0.05). There was no significant difference in mean bond strengths between groups 1 and 2 for each adhesive (p > 0.05). Depending on the adhesives, groups 3 and 4 were significantly different from groups 1 and 2, but not different from each other. Operator experience influences dentin bond strength values of dentin adhesives. An increased level of experience with a specific adhesive system and the associated application procedures correlates with higher SBSs.
- 1 June 2012
- Vol. 14 (3) , 223-227
Influence of Operator Experience on In Vitro Bond Strength of Dentin Adhesives
To examine the influence of operator experience level on shear bond strength (SBS) of a self-etching adhesive (Clearfil SE Bond [CSE], Kuraray) and an etch-and-rinse adhesive (Single Bond [SB], 3M ESPE). Flat dentin surfaces were created on 120 extracted human third molars. Bonding agents and composite resin were applied and light cured according to manufacturers' directions (n = 15). Four operators with different levels of experience in operative dentistry performed the same specimen preparation steps independently: group 1: specialist in operative dentistry; group 2: post-graduate student; group 3: undergraduate dental student; group 4: private general practitioner. Specimens were stored in distilled water for 24 h at 37°C before SBS testing. Statistical analyses were carried out with Mann-Whitney U- and Kruskall-Wallis tests. For CSE, mean SBS and standard deviations were: (1) 54.4 ± 15.6(a), (2) 55.3 ± 7.6(a), (3) 49.4 ± 10.5(ab), (4) 41.6 ± 13.1(b). For SB, they were: (1) 28.6 ± 10.3(c), (2) 32.7 ± 11.2(c), (3) 17.5 ± 5.6(d), (4) 24.4 ± 9.5(cd). Groups with the same superscript letters are not significantly different. CSE showed higher bond strengths than SB in all groups (p < 0.05). There was no significant difference in mean bond strengths between groups 1 and 2 for each adhesive (p > 0.05). Depending on the adhesives, groups 3 and 4 were significantly different from groups 1 and 2, but not different from each other. Operator experience influences dentin bond strength values of dentin adhesives. An increased level of experience with a specific adhesive system and the associated application procedures correlates with higher SBSs.
- 1 June 2012
- Published by Elsevier in Journal of Evidence-Based Dental Practice
- Vol. 12 (2) , 69-70
Laser Therapy may be Better Than Topical Desensitizing Agents for Treating Dentin Hypersensitivity
- 1 June 2012
- Published by Elsevier in Journal of Evidence-Based Dental Practice
- Vol. 12 (2) , 69-70
Laser Therapy may be Better Than Topical Desensitizing Agents for Treating Dentin Hypersensitivity
- 1 August 2010
- Vol. 23 (4) , 213-6
Bond strength of different veneering ceramics to zirconia and their susceptibility to thermocycling.
To evaluate the bond strength of recently developed feldspathic veneering ceramics to zirconium-oxide ceramic core material (Y-TZP). In addition, the effect of thermocycling on the bond strength was investigated. 90 square Lava framework Y-TZP specimens were randomly assigned to three groups (n = 30) and veneered with one of the three zirconia veneering ceramics Cerabien ZR (CZR), GC Initial (GCI), or Lava Ceram (LC). 30 additional metal-ceramic specimens served as the control (VO). 15 specimens per group were stored in a saline solution for 3 days. To test the durability of the bond, 15 specimens per group were thermocycled for 10,000 cycles between 5 degrees to 60 degrees C with a 15-second dwell time. Shear strength was tested with an Instron universal testing system. A two-way ANOVA model and Tukey's HSD were applied for statistical analyses (alpha = 0.05). The different material combinations revealed significantly different shear bond strength values (CZR > GCI > LC > VO). All veneering ceramic/zirconia combinations showed significantly higher bond strength than the metal-ceramic control VO. Bond strength values were not affected by thermocycling, except for CZR, which had significantly higher bond strength after thermocycling. Microscopic evaluation of failure modes revealed 100% cohesive failures in the veneering ceramic for all specimens.
- 1 August 2010
- Vol. 23 (4) , 213-6
Bond strength of different veneering ceramics to zirconia and their susceptibility to thermocycling.
To evaluate the bond strength of recently developed feldspathic veneering ceramics to zirconium-oxide ceramic core material (Y-TZP). In addition, the effect of thermocycling on the bond strength was investigated. 90 square Lava framework Y-TZP specimens were randomly assigned to three groups (n = 30) and veneered with one of the three zirconia veneering ceramics Cerabien ZR (CZR), GC Initial (GCI), or Lava Ceram (LC). 30 additional metal-ceramic specimens served as the control (VO). 15 specimens per group were stored in a saline solution for 3 days. To test the durability of the bond, 15 specimens per group were thermocycled for 10,000 cycles between 5 degrees to 60 degrees C with a 15-second dwell time. Shear strength was tested with an Instron universal testing system. A two-way ANOVA model and Tukey's HSD were applied for statistical analyses (alpha = 0.05). The different material combinations revealed significantly different shear bond strength values (CZR > GCI > LC > VO). All veneering ceramic/zirconia combinations showed significantly higher bond strength than the metal-ceramic control VO. Bond strength values were not affected by thermocycling, except for CZR, which had significantly higher bond strength after thermocycling. Microscopic evaluation of failure modes revealed 100% cohesive failures in the veneering ceramic for all specimens.
- 1 November 2009
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 67 (11) , 74-81
Zirconia Abutments for Single-Tooth Implants—Rationale and Clinical Guidelines
- 1 November 2009
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 67 (11) , 74-81
Zirconia Abutments for Single-Tooth Implants—Rationale and Clinical Guidelines