Stefan Holst
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Stefan Holst has a total of 41 co-authors. Here are the top co-authors by number of shared publications:
Manfred Wichmann
17 shared publications- Johannes Schmitt
Department of Prosthodontics, Friedrich-Alexander-University Erlangen-Nuremberg, Erlangen, Germany
8 shared publications - Markus B. Blatz
Department of Preventive and Restorative Sciences, Robert Schattner Center, University of Pennsylvania, School of Dental Medicine, 240 S. 40th Street, Philadelphia, PA 19104, USA
7 shared publications Markus B. Blatz
5 shared publicationsStephan Eitner
5 shared publications- Stephan Eitner
Department of Prosthodontics, Erlangen University Hospital, Erlangen, Germany
5 shared publications
Latest Publications
- 1 April 2013
- Vol. 44 (4) , 307-316
Correlations between tooth mobility and the Periotest method in periodontally involved teeth
The aim of this clinical study was to evaluate whether a correlation exists between three-dimensional tooth mobility (TM) and Periotest values for maxillary anterior periodontally involved teeth (pocket depth > 3 mm) before and after periodontal therapy. Force-related TM was measured in 3 N intervals in 19 participants as they bit down on a load cell. Periotest values were evaluated at reproducible measurement points. Both measurement techniques were performed on maxillary central and lateral incisors and canine teeth before periodontal treatment and after a healing period of 3 months. The Pearson product-moment correlation coefficient was calculated to determine exploratory associations. The comparison between TM and Periotest values indicated "high" and "optimum" correlations for maxillary central incisors before and after periodontal therapy. Lateral incisors exhibited "moderate" and "high" correlations, whereas canines exhibited "weak" and "moderate" correlations before and after periodontal therapy. Periotest values may provide valuable information about quantitative metric tooth mobility in periodontally involved teeth. In future investigations, the study design can expand on various dental fields, such as implantology and traumatology.
- 1 April 2013
- Vol. 44 (4) , 307-316
Correlations between tooth mobility and the Periotest method in periodontally involved teeth
The aim of this clinical study was to evaluate whether a correlation exists between three-dimensional tooth mobility (TM) and Periotest values for maxillary anterior periodontally involved teeth (pocket depth > 3 mm) before and after periodontal therapy. Force-related TM was measured in 3 N intervals in 19 participants as they bit down on a load cell. Periotest values were evaluated at reproducible measurement points. Both measurement techniques were performed on maxillary central and lateral incisors and canine teeth before periodontal treatment and after a healing period of 3 months. The Pearson product-moment correlation coefficient was calculated to determine exploratory associations. The comparison between TM and Periotest values indicated "high" and "optimum" correlations for maxillary central incisors before and after periodontal therapy. Lateral incisors exhibited "moderate" and "high" correlations, whereas canines exhibited "weak" and "moderate" correlations before and after periodontal therapy. Periotest values may provide valuable information about quantitative metric tooth mobility in periodontally involved teeth. In future investigations, the study design can expand on various dental fields, such as implantology and traumatology.
- 1 October 2012
- Vol. 43 (9) , 801-9
Circumferential fit assessment of CAD/CAM single crowns--a pilot investigation on a new virtual analytical protocol.
Techniques currently applied to determine the marginal accuracy of dental crown restorations yield inadequate information. This investigation aimed to test a new virtual approach for determining the precision of fit of single-crown copings. Zirconia single crown copings were manufactured on 10 gypsum, single-tooth master casts with two different established computer-aided design/computer-assisted manufacture (CAD/CAM) systems (groups A and B). After cementation, the circumferential fit was assessed with an industrial noncontact scanner and virtual 3D analysis, following a triple-scan protocol. Marginal fit was determined by virtual sectioning; each abutment-coping complex was digitally sliced in 360 vertical sections (1 degree per section). Standardized measurement distances for analyzing the marginal fit (z, xy, xyz) were selected, and a crosshair alignment was utilized to determine whether crowns were horizontally and/or vertically too large or small. The Mann-Whitney test was applied to test for differences between groups. Significant differences in the xy direction (P = .008) were measured between groups. Group A showed a greater number of horizontally overextended margins and a higher frequency of xy distances greater than 150 Μm, in addition to a tendency for excessive z distances (P = .095). The mean marginal gap values were clinically acceptable in the present investigation; however, a full circumferential analysis revealed significant differences in marginal coping quality.
- 1 October 2012
- Vol. 43 (9) , 801-9
Circumferential fit assessment of CAD/CAM single crowns--a pilot investigation on a new virtual analytical protocol.
Techniques currently applied to determine the marginal accuracy of dental crown restorations yield inadequate information. This investigation aimed to test a new virtual approach for determining the precision of fit of single-crown copings. Zirconia single crown copings were manufactured on 10 gypsum, single-tooth master casts with two different established computer-aided design/computer-assisted manufacture (CAD/CAM) systems (groups A and B). After cementation, the circumferential fit was assessed with an industrial noncontact scanner and virtual 3D analysis, following a triple-scan protocol. Marginal fit was determined by virtual sectioning; each abutment-coping complex was digitally sliced in 360 vertical sections (1 degree per section). Standardized measurement distances for analyzing the marginal fit (z, xy, xyz) were selected, and a crosshair alignment was utilized to determine whether crowns were horizontally and/or vertically too large or small. The Mann-Whitney test was applied to test for differences between groups. Significant differences in the xy direction (P = .008) were measured between groups. Group A showed a greater number of horizontally overextended margins and a higher frequency of xy distances greater than 150 Μm, in addition to a tendency for excessive z distances (P = .095). The mean marginal gap values were clinically acceptable in the present investigation; however, a full circumferential analysis revealed significant differences in marginal coping quality.
- 1 May 2011
- Vol. 42 (5) , 413-8
Five-year clinical follow-up of prefabricated precision attachments: a comparison of uni- and bilateral removable dental prostheses.
To evaluate the clinical long-term success of prefabricated precision attachments in retaining uni- or bilateral removable dental prostheses. Twenty-three patients with uni- or bilateral shortened dental arches received removable dental prostheses attached to the residual dentition with two types of precision attachments. After 5 years, 70% of bilateral and 25% of unilateral removable dental prostheses remained clinically functional. The most frequent cause of clinical failure was fracture of the abutment teeth for bilateral partial dentures and irreversible wear of the precision attachment for unilateral prostheses. Oral hygiene status significantly improved, and the mean pocket depth of the abutment teeth did not increase after 5 years. Removable partial denture prostheses, retained bilaterally with precision attachments, are a reliable treatment modality without negative long-term effects on periodontal health, whereas unilateral removable dental prostheses cannot be recommended because of high clinical failure rates.
- 1 May 2011
- Vol. 42 (5) , 413-8
Five-year clinical follow-up of prefabricated precision attachments: a comparison of uni- and bilateral removable dental prostheses.
To evaluate the clinical long-term success of prefabricated precision attachments in retaining uni- or bilateral removable dental prostheses. Twenty-three patients with uni- or bilateral shortened dental arches received removable dental prostheses attached to the residual dentition with two types of precision attachments. After 5 years, 70% of bilateral and 25% of unilateral removable dental prostheses remained clinically functional. The most frequent cause of clinical failure was fracture of the abutment teeth for bilateral partial dentures and irreversible wear of the precision attachment for unilateral prostheses. Oral hygiene status significantly improved, and the mean pocket depth of the abutment teeth did not increase after 5 years. Removable partial denture prostheses, retained bilaterally with precision attachments, are a reliable treatment modality without negative long-term effects on periodontal health, whereas unilateral removable dental prostheses cannot be recommended because of high clinical failure rates.
- 13 April 2011
- Vol. 26 (2) , 257-64
The effect of axial and oblique loading on the micromovement of dental implants.
To quantify implant displacement upon axial and oblique force application and compare the effects of bone quality using an in vitro experimental setup. One hundred ninety-two implants were inserted into artificial bone block specimens using a drill guide. Ninety-six implants were placed in soft cancellous bone and loaded in 10-N increments up to 80 N in axial and oblique (30-degree angle) directions (n = 48 in each group). The other 96 implants were inserted in dense artificial bone and loaded in axial and oblique directions in the same force increments. Three-dimensional displacement data were recorded for all implants using a noncontact optical image correlation technique based on photogrammetric principles, and the absolute displacement vector was calculated. There were significant differences in the absolute implant displacement in the different bone densities over all load increments. Implant displacement was significantly higher in soft cancellous bone than in dense bone. Axial and oblique loading revealed significant differences in implant displacement in the cancellous specimens, whereas oblique loading showed increased displacement (339 ± 47 Μm at 80 N) compared to axial loading (266 ± 39 Μm at 80 N). However, axial and oblique loading showed no significant differences over all load increments when implants were inserted in dense specimens (absolute displacement with an 80-N load: 147 ± 10 Μm axial and 126 ± 17 Μm oblique). Bone density influenced implant displacement. The loading character (axial versus oblique) significantly influenced implant displacement in soft cancellous bone block specimens only. However, the limitation of the measured displacement values to an in vitro application that did not represent the complexity of vital bone has to be considered.
- 13 April 2011
- Vol. 26 (2) , 257-64
The effect of axial and oblique loading on the micromovement of dental implants.
To quantify implant displacement upon axial and oblique force application and compare the effects of bone quality using an in vitro experimental setup. One hundred ninety-two implants were inserted into artificial bone block specimens using a drill guide. Ninety-six implants were placed in soft cancellous bone and loaded in 10-N increments up to 80 N in axial and oblique (30-degree angle) directions (n = 48 in each group). The other 96 implants were inserted in dense artificial bone and loaded in axial and oblique directions in the same force increments. Three-dimensional displacement data were recorded for all implants using a noncontact optical image correlation technique based on photogrammetric principles, and the absolute displacement vector was calculated. There were significant differences in the absolute implant displacement in the different bone densities over all load increments. Implant displacement was significantly higher in soft cancellous bone than in dense bone. Axial and oblique loading revealed significant differences in implant displacement in the cancellous specimens, whereas oblique loading showed increased displacement (339 ± 47 Μm at 80 N) compared to axial loading (266 ± 39 Μm at 80 N). However, axial and oblique loading showed no significant differences over all load increments when implants were inserted in dense specimens (absolute displacement with an 80-N load: 147 ± 10 Μm axial and 126 ± 17 Μm oblique). Bone density influenced implant displacement. The loading character (axial versus oblique) significantly influenced implant displacement in soft cancellous bone block specimens only. However, the limitation of the measured displacement values to an in vitro application that did not represent the complexity of vital bone has to be considered.
- 1 January 2011
- Vol. 77, b31
Surface characteristics of zirconia-based posterior restorations: clinical and scanning electron microscopic analysis.
The aim of this prospective clinical trial was to evaluate the performance of zirconia-based all-ceramic posterior fixed partial dentures (FPDs) after 4 years of clinical use. Fifteen patients who needed 3- or 4-unit posterior FPDs were enrolled in the study. One manufacturer fabricated all restorations, following established clinical protocols and using computer-aided design/computer-aided manufacturing technology and one veneering material. Survival and success were evaluated clinically. Impressions were taken immediately after definitive cementation and after 48 months. Gold-coated epoxy replicas of the restorations were analyzed with scanning electron microscopy (SEM). Surface alterations were also evaluated clinically. After 48 months, the survival rate for the FPDs was 100%. Three restorations exhibited minor chipping, for a fracture rate of 20% after 4 years. Thirty (59%) of the 51 individual restoration units revealed clinically rough occlusal surfaces, a finding that was confirmed by SEM. The placement of 3- and 4-unit zirconia-based posterior FPDs can be considered a reliable treatment modality for medium-term clinical use. However, surface alterations of the veneering ceramics were observed after 4 years and are of notable clinical concern.
- 1 January 2011
- Vol. 77, b31
Surface characteristics of zirconia-based posterior restorations: clinical and scanning electron microscopic analysis.
The aim of this prospective clinical trial was to evaluate the performance of zirconia-based all-ceramic posterior fixed partial dentures (FPDs) after 4 years of clinical use. Fifteen patients who needed 3- or 4-unit posterior FPDs were enrolled in the study. One manufacturer fabricated all restorations, following established clinical protocols and using computer-aided design/computer-aided manufacturing technology and one veneering material. Survival and success were evaluated clinically. Impressions were taken immediately after definitive cementation and after 48 months. Gold-coated epoxy replicas of the restorations were analyzed with scanning electron microscopy (SEM). Surface alterations were also evaluated clinically. After 48 months, the survival rate for the FPDs was 100%. Three restorations exhibited minor chipping, for a fracture rate of 20% after 4 years. Thirty (59%) of the 51 individual restoration units revealed clinically rough occlusal surfaces, a finding that was confirmed by SEM. The placement of 3- and 4-unit zirconia-based posterior FPDs can be considered a reliable treatment modality for medium-term clinical use. However, surface alterations of the veneering ceramics were observed after 4 years and are of notable clinical concern.
- 1 August 2010
- Vol. 23 (4) , 213-6
Bond strength of different veneering ceramics to zirconia and their susceptibility to thermocycling.
To evaluate the bond strength of recently developed feldspathic veneering ceramics to zirconium-oxide ceramic core material (Y-TZP). In addition, the effect of thermocycling on the bond strength was investigated. 90 square Lava framework Y-TZP specimens were randomly assigned to three groups (n = 30) and veneered with one of the three zirconia veneering ceramics Cerabien ZR (CZR), GC Initial (GCI), or Lava Ceram (LC). 30 additional metal-ceramic specimens served as the control (VO). 15 specimens per group were stored in a saline solution for 3 days. To test the durability of the bond, 15 specimens per group were thermocycled for 10,000 cycles between 5 degrees to 60 degrees C with a 15-second dwell time. Shear strength was tested with an Instron universal testing system. A two-way ANOVA model and Tukey's HSD were applied for statistical analyses (alpha = 0.05). The different material combinations revealed significantly different shear bond strength values (CZR > GCI > LC > VO). All veneering ceramic/zirconia combinations showed significantly higher bond strength than the metal-ceramic control VO. Bond strength values were not affected by thermocycling, except for CZR, which had significantly higher bond strength after thermocycling. Microscopic evaluation of failure modes revealed 100% cohesive failures in the veneering ceramic for all specimens.
- 1 August 2010
- Vol. 23 (4) , 213-6
Bond strength of different veneering ceramics to zirconia and their susceptibility to thermocycling.
To evaluate the bond strength of recently developed feldspathic veneering ceramics to zirconium-oxide ceramic core material (Y-TZP). In addition, the effect of thermocycling on the bond strength was investigated. 90 square Lava framework Y-TZP specimens were randomly assigned to three groups (n = 30) and veneered with one of the three zirconia veneering ceramics Cerabien ZR (CZR), GC Initial (GCI), or Lava Ceram (LC). 30 additional metal-ceramic specimens served as the control (VO). 15 specimens per group were stored in a saline solution for 3 days. To test the durability of the bond, 15 specimens per group were thermocycled for 10,000 cycles between 5 degrees to 60 degrees C with a 15-second dwell time. Shear strength was tested with an Instron universal testing system. A two-way ANOVA model and Tukey's HSD were applied for statistical analyses (alpha = 0.05). The different material combinations revealed significantly different shear bond strength values (CZR > GCI > LC > VO). All veneering ceramic/zirconia combinations showed significantly higher bond strength than the metal-ceramic control VO. Bond strength values were not affected by thermocycling, except for CZR, which had significantly higher bond strength after thermocycling. Microscopic evaluation of failure modes revealed 100% cohesive failures in the veneering ceramic for all specimens.
- 23 March 2010
- Vol. 23 (2) , 107-9
Restoring severely compromised anterior teeth with zirconia crowns and feather-edged margin preparations: a 3-year follow-up of a prospective clinical trial.
This prospective clinical trial sought to evaluate the 3-year clinical results of anterior teeth restored with 0.3-mm-thick zirconia copings and feather-edged marginal preparations. Ten patients received 19 single-tooth restorations in the anterior maxilla to restore severely decayed teeth. After a mean observation period of 39.2 months, no material fracture occurred and all crowns had acceptable surfaces. A survival and success rate of 100% was recorded, which suggests that the clinical method may be a reliable treatment modality for restoring severely compromised anterior teeth.
- 23 March 2010
- Vol. 23 (2) , 107-9
Restoring severely compromised anterior teeth with zirconia crowns and feather-edged margin preparations: a 3-year follow-up of a prospective clinical trial.
This prospective clinical trial sought to evaluate the 3-year clinical results of anterior teeth restored with 0.3-mm-thick zirconia copings and feather-edged marginal preparations. Ten patients received 19 single-tooth restorations in the anterior maxilla to restore severely decayed teeth. After a mean observation period of 39.2 months, no material fracture occurred and all crowns had acceptable surfaces. A survival and success rate of 100% was recorded, which suggests that the clinical method may be a reliable treatment modality for restoring severely compromised anterior teeth.
- 1 January 2010
- Vol. 41 (1) , 59-66
Quantitative assessment of orthodontic mini-implant displacement: the effect of initial force application.
Primary stability and micromovement of orthodontic mini-implants depends on a number of factors and influences clinical success or failure. The purpose of this study was to assess the behavior of orthodontic mini-implants upon initial load application. Orthodontic mini-implants (n = 39) were inserted in the alveolar process of maxillary human cadaver specimens (n = 10). Increasing horizontal forces (up to 2.5 N) were applied, and triggered images were taken in 0.5-N load intervals. Additionally, peri-implant parameters based on micro-CT volume data were recorded. Data were subjected to a two-sided nonparametric Wilcoxon signed rank test, and between-group comparisons were assessed with a Mann-Whitney test (alpha = .05). Initial load application led to displacement beyond elastic recovery of the surrounding bone after force release (P < .001). Cortical thickness and insertion depth, despite numeric differences, did not reveal any statistical differences, while displacement of mini-implants was significantly affected by contact to neighboring teeth (P < .001). Insertion technique and initial load application on orthodontic mini-implants may be regarded as two crucial factors for success, while repeated application of orthodontic force does not seem to increase screw mobility.
- 1 January 2010
- Vol. 41 (1) , 59-66
Quantitative assessment of orthodontic mini-implant displacement: the effect of initial force application.
Primary stability and micromovement of orthodontic mini-implants depends on a number of factors and influences clinical success or failure. The purpose of this study was to assess the behavior of orthodontic mini-implants upon initial load application. Orthodontic mini-implants (n = 39) were inserted in the alveolar process of maxillary human cadaver specimens (n = 10). Increasing horizontal forces (up to 2.5 N) were applied, and triggered images were taken in 0.5-N load intervals. Additionally, peri-implant parameters based on micro-CT volume data were recorded. Data were subjected to a two-sided nonparametric Wilcoxon signed rank test, and between-group comparisons were assessed with a Mann-Whitney test (alpha = .05). Initial load application led to displacement beyond elastic recovery of the surrounding bone after force release (P < .001). Cortical thickness and insertion depth, despite numeric differences, did not reveal any statistical differences, while displacement of mini-implants was significantly affected by contact to neighboring teeth (P < .001). Insertion technique and initial load application on orthodontic mini-implants may be regarded as two crucial factors for success, while repeated application of orthodontic force does not seem to increase screw mobility.
- 18 November 2009
- Vol. 22 (6) , 597-603
Zirconia posterior fixed partial dentures: a prospective clinical 3-year follow-up.
The aim of this prospective clinical trial was to evaluate the reliability of three- and four-unit posterior fixed partial dentures (FPDs) with zirconia frameworks after 3 years of clinical function. Thirty patients, each needing a posterior FPD to restore one or two missing teeth, were included in the study. Preparation guidelines were: occlusal reduction of 1.5 to 2 mm, axial reduction of 1.5 mm, and circumferential chamfer preparation placed 0.5 mm subgingivally. Frameworks were fabricated using a computer-aided design/computer-assisted manufacture technique. All FPDs were cemented with glass-ionomer cement. At baseline and 12, 24, and 36 months after cementation, survival and success of the zirconia framework and the ceramic veneer were evaluated. To analyze the effect of placement of an all-ceramic restoration on the gingival tissue, Gingival Index, Plaque Index, sulcus bleeding index, and pocket depth at abutment (test) and contralateral analogous teeth (control) were assessed. Data were analyzed by descriptive statistics, the Wilcoxon test, and the McNemar test. Of the 30 initial subjects, 27 patients with 27 zirconia FPDs were examined after a mean testing period of 34.2 months. All FPDs were still in use and unfractured, resulting in a 100% survival rate for the frameworks. One FPD exhibited a major chip after 36 months. The cumulative success rate was 96.3%. No significant differences between the periodontal parameters of the test and control teeth were observed. The Plaque Index revealed significantly higher scores for mesial and distal control teeth at baseline and after 12 and 24 months for distal control teeth. Posterior zirconia-based three- and four-unit FPDs present a reliable treatment modality after medium-term clinical use.
- 18 November 2009
- Vol. 22 (6) , 597-603
Zirconia posterior fixed partial dentures: a prospective clinical 3-year follow-up.
The aim of this prospective clinical trial was to evaluate the reliability of three- and four-unit posterior fixed partial dentures (FPDs) with zirconia frameworks after 3 years of clinical function. Thirty patients, each needing a posterior FPD to restore one or two missing teeth, were included in the study. Preparation guidelines were: occlusal reduction of 1.5 to 2 mm, axial reduction of 1.5 mm, and circumferential chamfer preparation placed 0.5 mm subgingivally. Frameworks were fabricated using a computer-aided design/computer-assisted manufacture technique. All FPDs were cemented with glass-ionomer cement. At baseline and 12, 24, and 36 months after cementation, survival and success of the zirconia framework and the ceramic veneer were evaluated. To analyze the effect of placement of an all-ceramic restoration on the gingival tissue, Gingival Index, Plaque Index, sulcus bleeding index, and pocket depth at abutment (test) and contralateral analogous teeth (control) were assessed. Data were analyzed by descriptive statistics, the Wilcoxon test, and the McNemar test. Of the 30 initial subjects, 27 patients with 27 zirconia FPDs were examined after a mean testing period of 34.2 months. All FPDs were still in use and unfractured, resulting in a 100% survival rate for the frameworks. One FPD exhibited a major chip after 36 months. The cumulative success rate was 96.3%. No significant differences between the periodontal parameters of the test and control teeth were observed. The Plaque Index revealed significantly higher scores for mesial and distal control teeth at baseline and after 12 and 24 months for distal control teeth. Posterior zirconia-based three- and four-unit FPDs present a reliable treatment modality after medium-term clinical use.
- 8 May 2009
- Vol. 22 (2) , 193-200
Prosthetic screw detorque values in implants retained as cast bar superstructures or bars modified by the Cresco Ti Precision technique--a comparative in vivo study.
This prospective clinical trial investigated the effect of different fabrication techniques on screw-joint stability in implant-retained frameworks. Seventy-nine dental implants (39 Brånemark System and 40 Straumann) were inserted into 20 patients with an edentulous mandible. One of two fabrication techniques was randomly chosen as a definitive restoration, either a cast bar or a bar superstructure modified with the Cresco Ti Precision (CTiP) technique. The patients were divided into four groups depending on the type of implant and prosthetic superstructure: Straumann-conventional (Sc), Straumann-Cresco (SCr), Brånemark-conventional (Bc), and Brånemark-Cresco (BCr). Initial torque values and removal torque values were recorded with a custom-made digital torque controller both 1 week (T1) and 3 months (T2) after clinical function. Statistical analysis revealed significant differences in absolute detorque values at T1 (P = .002) with 4.51 Ncm (SD = 3.80) for the Sc group, 10.65 Ncm (SD = 4.42) for SCr, 11.24 Ncm (SD = 4.00) for Bc, and 9.02 Ncm (SD = 3.81) for BCr. At T2 (P = .000) the median values of lost torque were 5.08 Ncm (SD = 4.05) for the Sc group, 10.51 (SD = 3.00) for SCr, 7.50 (SD = 5.86) for Bc, and 9.41 Ncm (SD = 4.54) for BCr. However, when correlation of detorque values to initial torque values was performed, no statistical differences were found between groups or time points. The percentage of lost torque at T1 (P = .849) and T2 (P = .058) was 28.60% (SD = 21.80) and 32.85% (SD = 24.65), 30.04% (SD = 12.49) and 30.80% (SD = 8.66), 32.11% (SD = 11.37) and 21.03% (SD = 16.53), and 25.33% (SD = 10.69) and 27.83% (SD = 12.57) for the Sc, SCr, Bc, and BCr groups, respectively. The screw-joint stability of passivated bars is not superior to cast superstructures. A general decrease of approximately 30% of initial torque values can be expected in clinical situations, independent of the implant system used.
- 8 May 2009
- Vol. 22 (2) , 193-200
Prosthetic screw detorque values in implants retained as cast bar superstructures or bars modified by the Cresco Ti Precision technique--a comparative in vivo study.
This prospective clinical trial investigated the effect of different fabrication techniques on screw-joint stability in implant-retained frameworks. Seventy-nine dental implants (39 Brånemark System and 40 Straumann) were inserted into 20 patients with an edentulous mandible. One of two fabrication techniques was randomly chosen as a definitive restoration, either a cast bar or a bar superstructure modified with the Cresco Ti Precision (CTiP) technique. The patients were divided into four groups depending on the type of implant and prosthetic superstructure: Straumann-conventional (Sc), Straumann-Cresco (SCr), Brånemark-conventional (Bc), and Brånemark-Cresco (BCr). Initial torque values and removal torque values were recorded with a custom-made digital torque controller both 1 week (T1) and 3 months (T2) after clinical function. Statistical analysis revealed significant differences in absolute detorque values at T1 (P = .002) with 4.51 Ncm (SD = 3.80) for the Sc group, 10.65 Ncm (SD = 4.42) for SCr, 11.24 Ncm (SD = 4.00) for Bc, and 9.02 Ncm (SD = 3.81) for BCr. At T2 (P = .000) the median values of lost torque were 5.08 Ncm (SD = 4.05) for the Sc group, 10.51 (SD = 3.00) for SCr, 7.50 (SD = 5.86) for Bc, and 9.41 Ncm (SD = 4.54) for BCr. However, when correlation of detorque values to initial torque values was performed, no statistical differences were found between groups or time points. The percentage of lost torque at T1 (P = .849) and T2 (P = .058) was 28.60% (SD = 21.80) and 32.85% (SD = 24.65), 30.04% (SD = 12.49) and 30.80% (SD = 8.66), 32.11% (SD = 11.37) and 21.03% (SD = 16.53), and 25.33% (SD = 10.69) and 27.83% (SD = 12.57) for the Sc, SCr, Bc, and BCr groups, respectively. The screw-joint stability of passivated bars is not superior to cast superstructures. A general decrease of approximately 30% of initial torque values can be expected in clinical situations, independent of the implant system used.