Matthias Ziefle
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Matthias Ziefle has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Udo Nackenhorst
Institute of Mechanics and Computational Mechanics (IBNM), Leibniz University Hannover, Hannover, Germany
6 shared publications - Anuwat Suwannachit
Leibniz Universität Hannover
1 shared publication - Christian Krettek
Professor em., Trauma Department, Hannover Medical School, Hannover, Germany
1 shared publication P Wilmes
1 shared publication- Thomas Gösling
Städtisches Klinikum Braunschweig gGmbH
1 shared publication - Torsten Gerich
Centre Hospitalier de Luxembourg , 4, rue Barble, Luxembourg L-1210, Luxembourg
1 shared publication
Latest Publications
- 1 January 2011
- No. 2,p. 57-70
A clinical, radiological and computational analysis of the thrust plate prosthesis in young patients.
A thrust plate prosthesis can be used as an alternative to a conventional stem prosthesis, preserving the diaphyseal bone stock. Recent findings however predict a higher rate of aseptic loosening than with intramedullary devices. The purpose of our investigation was to compare the clinical outcome and radiological findings with a finite element analysis of bone remodeling. The hypothesis was that aseptic loosening after thrust plate prosthesis of the hip is inherent to the design. From 1997 to 2001, 58 thrust plates were implanted in 52 patients. Average age at the time of surgery was 40.9 years. Ninety four percent returned for follow up at an average of 26 months. A finite element model of the thrust plate within the femur was developed and stress shielding as well as bone remodeling were analyzed. A total of 4 patients required revision surgery (6.9%). Data from the finite element analysis revealed an inherent failure mechanism to the implant, facilitating stress shielding and loosening. Lacking the ideal total hip prosthesis in young patients, the thrust plate can still be regarded as a feasible implant. However, surgeons and patients should be aware of possible mechanical problems regarding the design of the thrust plate. There is evidence that thrust plate prostheses are prone to early aseptic loosening. Clinical and radiological observations are in agreement with the results from the numerical simulations. Stress concentrations computed at the leash are interpreted as an explanation for leash pain. The authors regard computational methods as an aid to improve existing prosthesis design and future developments.
- 1 January 2011
- No. 2,p. 57-70
A clinical, radiological and computational analysis of the thrust plate prosthesis in young patients.
A thrust plate prosthesis can be used as an alternative to a conventional stem prosthesis, preserving the diaphyseal bone stock. Recent findings however predict a higher rate of aseptic loosening than with intramedullary devices. The purpose of our investigation was to compare the clinical outcome and radiological findings with a finite element analysis of bone remodeling. The hypothesis was that aseptic loosening after thrust plate prosthesis of the hip is inherent to the design. From 1997 to 2001, 58 thrust plates were implanted in 52 patients. Average age at the time of surgery was 40.9 years. Ninety four percent returned for follow up at an average of 26 months. A finite element model of the thrust plate within the femur was developed and stress shielding as well as bone remodeling were analyzed. A total of 4 patients required revision surgery (6.9%). Data from the finite element analysis revealed an inherent failure mechanism to the implant, facilitating stress shielding and loosening. Lacking the ideal total hip prosthesis in young patients, the thrust plate can still be regarded as a feasible implant. However, surgeons and patients should be aware of possible mechanical problems regarding the design of the thrust plate. There is evidence that thrust plate prostheses are prone to early aseptic loosening. Clinical and radiological observations are in agreement with the results from the numerical simulations. Stress concentrations computed at the leash are interpreted as an explanation for leash pain. The authors regard computational methods as an aid to improve existing prosthesis design and future developments.
- 1 January 2010
- Published by Springer Nature
- p. 123-163
Finite Element Techniques for Rolling Rubber Wheels
- 1 January 2010
- Published by Springer Nature
- p. 123-163
Finite Element Techniques for Rolling Rubber Wheels
- 23 May 2008
- Published by Springer Nature
- p. 329
A Discontinuous Galerkin Approach for the Numerical Treatment of Tractive Rolling
- 23 May 2008
- Published by Springer Nature
- p. 329
A Discontinuous Galerkin Approach for the Numerical Treatment of Tractive Rolling
- 8 March 2008
- Published by Springer Nature in Computational Mechanics
- Vol. 42 (3) , 337-356
Numerical techniques for rolling rubber wheels: treatment of inelastic material properties and frictional contact
- 8 March 2008
- Published by Springer Nature in Computational Mechanics
- Vol. 42 (3) , 337-356
Numerical techniques for rolling rubber wheels: treatment of inelastic material properties and frictional contact
- 20 November 2007
- Published by Springer Nature
- p. 207-223
A Fully Implicit Approach for the Numerical Treatment of Tractive Rolling
- 20 November 2007
- Published by Springer Nature
- p. 207-223
A Fully Implicit Approach for the Numerical Treatment of Tractive Rolling
- Open Access
- 1 December 2006
- Published by Wiley in Proceedings in Applied Mathematics and Mechanics
- Vol. 6 (1) , 885-886
On the treatment of frictional rolling contact
- 1 December 2006
- Published by Wiley in Proceedings in Applied Mathematics and Mechanics
- Vol. 6 (1) , 885-886
Open AccessOn the treatment of frictional rolling contact
- 14 August 2006
- Published by Springer Nature
- Vol. 27, 391-392
On the treatment of inelastic material behavior in an ALE-description of rolling contact
- 14 August 2006
- Published by Springer Nature
- Vol. 27, 391-392
On the treatment of inelastic material behavior in an ALE-description of rolling contact