Tomonori Oie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Tomonori Oie has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Keiichi Kanda
Kyoto Prefectural University of Medicine
2 shared publications- Yasuhide Nakayama
Division of Medical Engineering and Materials, National Cerebral and Cardiovascular Center Research Institute, 5-7-1 Fujishirodai, Suita, Osaka, 565-8565, Japan.
2 shared publications Hatsue Ueda
National Cardiovascular Center
1 shared publication- Hitoshi Yaku
Department of Cardiovascular Surgery, Kyoto Prefectural University of Medicine, Kyoto, Japan
1 shared publication - Keiichi Takamizawa
National Cerebral and Cardiovascular Center Research Institute
1 shared publication Kenkichi Ohba
Kansai University
1 shared publication
Latest Publications
- 20 August 2011
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 14 (4) , 276-283
Variations in local elastic modulus along the length of the aorta as observed by use of a scanning haptic microscope (SHM)
Variations in microscopic elastic structures along the entire length of canine aorta were evaluated by use of a scanning haptic microscope (SHM). The total aorta from the aortic arch to the abdominal aorta was divided into 6 approximately equal segments. After embedding the aorta in agar, it was cut into horizontal circumferential segments to obtain disk-like agar portions containing ring-like samples of aorta with flat surfaces (thickness, approximately 1 mm). The elastic modulus and topography of the samples under no-load conditions were simultaneously measured along the entire thickness of the wall by SHM by using a probe with a diameter of 5 μm and a spatial resolution of 2 μm at a rate of 0.3 s/point. The elastic modulus of the wall was the highest on the side of the luminal surface and decreased gradually toward the adventitial side. This tendency was similar to that of the change in the elastin fiber content. During the evaluation of the mid-portion of each tunica media segment, the highest elastic modulus (40.8 ± 3.5 kPa) was identified at the thoracic section of the aorta that had the highest density of elastic fibers. Under no-load conditions, portions of the aorta with high elastin density have a high elastic modulus.
- 20 August 2011
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 14 (4) , 276-283
Variations in local elastic modulus along the length of the aorta as observed by use of a scanning haptic microscope (SHM)
Variations in microscopic elastic structures along the entire length of canine aorta were evaluated by use of a scanning haptic microscope (SHM). The total aorta from the aortic arch to the abdominal aorta was divided into 6 approximately equal segments. After embedding the aorta in agar, it was cut into horizontal circumferential segments to obtain disk-like agar portions containing ring-like samples of aorta with flat surfaces (thickness, approximately 1 mm). The elastic modulus and topography of the samples under no-load conditions were simultaneously measured along the entire thickness of the wall by SHM by using a probe with a diameter of 5 μm and a spatial resolution of 2 μm at a rate of 0.3 s/point. The elastic modulus of the wall was the highest on the side of the luminal surface and decreased gradually toward the adventitial side. This tendency was similar to that of the change in the elastin fiber content. During the evaluation of the mid-portion of each tunica media segment, the highest elastic modulus (40.8 ± 3.5 kPa) was identified at the thoracic section of the aorta that had the highest density of elastic fibers. Under no-load conditions, portions of the aorta with high elastin density have a high elastic modulus.
- 1 January 2007
- Published by Japan Society of Mechanical Engineers in The proceedings of the JSME annual meeting
- Vol. 2007.5, 293-294
1113 Evaluation in vitro of the function of an artificial substitute heart valve made in body tissue architecture technology
Various types of artificial substitute valves are developed for substituting for human heart valve. Hayashida et al. have made a new artificial substitute valve in body tissue architecture technology which is called a bio-valve. The bio-valve has many merits and expectations, for example, biocompatibility, no immune response, growth and self-reparation. Before implanting the developed substitute valve into an animal for animal experiment, it is necessary to evaluate the function of the substitute valve in vitro. In this study, we evaluate in vitro the function of the substitute valve made in body tissue architecture technology in a rabbit body.
- 1 January 2007
- Published by Japan Society of Mechanical Engineers in The proceedings of the JSME annual meeting
- Vol. 2007.5, 293-294
1113 Evaluation in vitro of the function of an artificial substitute heart valve made in body tissue architecture technology
Various types of artificial substitute valves are developed for substituting for human heart valve. Hayashida et al. have made a new artificial substitute valve in body tissue architecture technology which is called a bio-valve. The bio-valve has many merits and expectations, for example, biocompatibility, no immune response, growth and self-reparation. Before implanting the developed substitute valve into an animal for animal experiment, it is necessary to evaluate the function of the substitute valve in vitro. In this study, we evaluate in vitro the function of the substitute valve made in body tissue architecture technology in a rabbit body.