Variations in local elastic modulus along the length of the aorta as observed by use of a scanning haptic microscope (SHM)
- 20 August 2011
- journal article
- Published by Springer Nature in Journal of Artificial Organs
- Vol. 14 (4) , 276-283
Abstract
Variations in microscopic elastic structures along the entire length of canine aorta were evaluated by use of a scanning haptic microscope (SHM). The total aorta from the aortic arch to the abdominal aorta was divided into 6 approximately equal segments. After embedding the aorta in agar, it was cut into horizontal circumferential segments to obtain disk-like agar portions containing ring-like samples of aorta with flat surfaces (thickness, approximately 1 mm). The elastic modulus and topography of the samples under no-load conditions were simultaneously measured along the entire thickness of the wall by SHM by using a probe with a diameter of 5 μm and a spatial resolution of 2 μm at a rate of 0.3 s/point. The elastic modulus of the wall was the highest on the side of the luminal surface and decreased gradually toward the adventitial side. This tendency was similar to that of the change in the elastin fiber content. During the evaluation of the mid-portion of each tunica media segment, the highest elastic modulus (40.8 ± 3.5 kPa) was identified at the thoracic section of the aorta that had the highest density of elastic fibers. Under no-load conditions, portions of the aorta with high elastin density have a high elastic modulus.Keywords
This publication has 23 references indexed in Scilit:
- Surgical Thoracic Sympathectomy Induces Structural and Biomechanical Remodeling of the Thoracic Aorta in a Porcine ModelJournal of Surgical Research, 2012
- Surface elasticity imaging of vascular tissues in a liquid environment by a scanning haptic microscopeJournal of Artificial Organs, 2010
- Autologous small‐caliber “Biotube” vascular grafts with argatroban loading: A histomorphological examination after implantation to rabbitsJournal of Biomedical Materials Research Part B: Applied Biomaterials, 2009
- Local elasticity imaging of vascular tissues using a tactile mapping systemJournal of Artificial Organs, 2009
- Micromechanical bending of single collagen fibrils using atomic force microscopyJournal of Biomedical Materials Research Part A, 2007
- Biomechanics of the cardiovascular system: the aorta as an illustratory exampleJournal of The Royal Society Interface, 2006
- Residual stress and strain in the lamellar unit of the porcine aorta: experiment and analysisJournal of Biomechanics, 2004
- Elastic proteins: biological roles and mechanical propertiesPhilosophical Transactions of the Royal Society B: Biological Sciences, 2002
- Atomic Force MicroscopePhysical Review Letters, 1986
- Mechanical properties of aortas and pulmonary arteries of calves implanted with cardiac prosthesesJournal of Biomechanics, 1981