Daniel L. Timms
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Daniel L. Timms has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- David G. Mason
MedTeQ, School of Information Technology & Electrical Engineering, The University of Queensland, Brisbane, Australia 4067
2 shared publications - John F. Fraser
Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia
2 shared publications - Shaun David Gregory
Advanced Cardiorespiratory Engineering Laboratory, Faculty of Engineering Queensland University of Technology Brisbane Australia
2 shared publications - Abdul-Hakeem H. AlOmari
Department of Biomedical Engineering, College of Engineering, University of Dammam, Dammam 31451, Kingdom of Saudi Arabia
1 shared publication Andrey V. Savkin
School of Electrical Engineering and Telecommunications
1 shared publication- Einly Lim
Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
1 shared publication
Latest Publications
- 15 August 2011
- Published by Wiley in Artificial Organs
- Vol. 35 (8) , E174-E180
A Method for Control of an Implantable Rotary Blood Pump for Heart Failure Patients Using Noninvasive Measurements
- 15 August 2011
- Published by Wiley in Artificial Organs
- Vol. 35 (8) , E174-E180
A Method for Control of an Implantable Rotary Blood Pump for Heart Failure Patients Using Noninvasive Measurements
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2011 (1094687X) , 4301-4304
Haemodynamic modeling of the cardiovascular system using mock circulation loops to test cardiovascular devices
Comprehensive testing and evaluation of cardiovascular device function and performance is required prior to clinical implementation. Initial proof of concept investigations are conducted within in-vitro mock circulation loops, before proof of principle is demonstrated via in-vivo animal testing. To facilitate the rapid transition of cardiovascular devices through this development period, a testing apparatus was developed that closely models the natural human cardiovascular system haemodynamics. This mock circulation system accurately replicates cardiac function, coupled to systemic and pulmonary circulations. The physiological response produced by a number of clinical cardiovascular conditions can be actively controlled by variable parameters such as vascular resistance, arterial/venous compliance, ventricle contractility, heart rate, and heart /vascular volumes, while anatomical variations such as valve regurgitation and septal defects can be included. Auto-regulation of these parameters was attempted to reproduce the Frank-Starling mechanism, baroreceptor reflex, skeletal muscle pump, and postural changes. Steady state validation of loop performance was achieved by replicating the progression of a patient's clinical haemodynamics from heart failure, through VAD support, to heart transplantation. The system has been used to evaluate pulsatile and non-pulsatile ventricular assist devices, counter pulsation devices, non-invasive cardiac output monitors and cardiovascular stents. The interaction of these devices with the cardiovascular system was also investigated with regards to physiological control strategies and cannula placement. The system is a valuable tool for the accelerated progression of cardiovascular device development.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2011 (1094687X) , 4301-4304
Haemodynamic modeling of the cardiovascular system using mock circulation loops to test cardiovascular devices
Comprehensive testing and evaluation of cardiovascular device function and performance is required prior to clinical implementation. Initial proof of concept investigations are conducted within in-vitro mock circulation loops, before proof of principle is demonstrated via in-vivo animal testing. To facilitate the rapid transition of cardiovascular devices through this development period, a testing apparatus was developed that closely models the natural human cardiovascular system haemodynamics. This mock circulation system accurately replicates cardiac function, coupled to systemic and pulmonary circulations. The physiological response produced by a number of clinical cardiovascular conditions can be actively controlled by variable parameters such as vascular resistance, arterial/venous compliance, ventricle contractility, heart rate, and heart /vascular volumes, while anatomical variations such as valve regurgitation and septal defects can be included. Auto-regulation of these parameters was attempted to reproduce the Frank-Starling mechanism, baroreceptor reflex, skeletal muscle pump, and postural changes. Steady state validation of loop performance was achieved by replicating the progression of a patient's clinical haemodynamics from heart failure, through VAD support, to heart transplantation. The system has been used to evaluate pulsatile and non-pulsatile ventricular assist devices, counter pulsation devices, non-invasive cardiac output monitors and cardiovascular stents. The interaction of these devices with the cardiovascular system was also investigated with regards to physiological control strategies and cannula placement. The system is a valuable tool for the accelerated progression of cardiovascular device development.
- 8 July 2011
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 39 (9) , 2313-2328
Biventricular Assist Devices: A Technical Review
The optimal treatment option for end stage heart failure is transplantation; however, the shortage of donor organs necessitates alternative treatment strategies such as mechanical circulatory assistance. Ventricular assist devices (VADs) are employed to support these cases while awaiting cardiac recovery or transplantation, or in some cases as destination therapy. While left ventricular assist device (LVAD) therapy alone is effective in many instances, up to 50% of LVAD recipients demonstrate clinically significant postoperative right ventricular failure and potentially need a biventricular assist device (BiVAD). In these cases, the BiVAD can effectively support both sides of the failing heart. This article presents a technical review of BiVADs, both clinically applied and under development. The BiVADs which have been used clinically are predominantly first generation, pulsatile, and paracorporeal systems that are bulky and prone to device failure, thrombus formation, and infection. While they have saved many lives, they generally necessitate a large external pneumatic driver which inhibits normal movement and quality of life for many patients. In an attempt to alleviate these issues, several smaller, implantable second and third generation devices that use either immersed mechanical blood bearings or hydrodynamic/magnetic levitation systems to support a rotating impeller are under development or in the early stages of clinical use. Although these rotary devices may offer a longer term, completely implantable option for patients with biventricular failure, their control strategies need to be refined to compete with the inherent volume balancing ability of the first generation devices. The BiVAD systems potentially offer an improved quality of life to patients with total heart failure, and thus a viable alternative to heart transplantation is anticipated with continued development.
- 8 July 2011
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 39 (9) , 2313-2328
Biventricular Assist Devices: A Technical Review
The optimal treatment option for end stage heart failure is transplantation; however, the shortage of donor organs necessitates alternative treatment strategies such as mechanical circulatory assistance. Ventricular assist devices (VADs) are employed to support these cases while awaiting cardiac recovery or transplantation, or in some cases as destination therapy. While left ventricular assist device (LVAD) therapy alone is effective in many instances, up to 50% of LVAD recipients demonstrate clinically significant postoperative right ventricular failure and potentially need a biventricular assist device (BiVAD). In these cases, the BiVAD can effectively support both sides of the failing heart. This article presents a technical review of BiVADs, both clinically applied and under development. The BiVADs which have been used clinically are predominantly first generation, pulsatile, and paracorporeal systems that are bulky and prone to device failure, thrombus formation, and infection. While they have saved many lives, they generally necessitate a large external pneumatic driver which inhibits normal movement and quality of life for many patients. In an attempt to alleviate these issues, several smaller, implantable second and third generation devices that use either immersed mechanical blood bearings or hydrodynamic/magnetic levitation systems to support a rotating impeller are under development or in the early stages of clinical use. Although these rotary devices may offer a longer term, completely implantable option for patients with biventricular failure, their control strategies need to be refined to compete with the inherent volume balancing ability of the first generation devices. The BiVAD systems potentially offer an improved quality of life to patients with total heart failure, and thus a viable alternative to heart transplantation is anticipated with continued development.