David G. Mason has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
- Daniel L. Timms
Critical Care Research Group, The Prince Charles Hospital
2 shared publications - John F. Fraser
Critical Care Research Group, The Prince Charles Hospital, Brisbane, Queensland, Australia
2 shared publications - Abdul-Hakeem H. AlOmari
Department of Biomedical Engineering, College of Engineering, University of Dammam, Dammam 31451, Kingdom of Saudi Arabia
1 shared publication Andrey V. Savkin
School of Electrical Engineering and Telecommunications
1 shared publication- Einly Lim
Department of Biomedical Engineering, Faculty of Engineering, University of Malaya, Kuala Lumpur, Malaysia
1 shared publication Jayne Bancroft
Intensive Care Unit, The Prince Charles Hospital, Brisbane, Australia
1 shared publication
Latest Publications
- 15 August 2011
- Published by Wiley in Artificial Organs
- Vol. 35 (8) , E174-E180
A Method for Control of an Implantable Rotary Blood Pump for Heart Failure Patients Using Noninvasive Measurements
- 15 August 2011
- Published by Wiley in Artificial Organs
- Vol. 35 (8) , E174-E180
A Method for Control of an Implantable Rotary Blood Pump for Heart Failure Patients Using Noninvasive Measurements
- 8 July 2011
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 39 (9) , 2313-2328
Biventricular Assist Devices: A Technical Review
The optimal treatment option for end stage heart failure is transplantation; however, the shortage of donor organs necessitates alternative treatment strategies such as mechanical circulatory assistance. Ventricular assist devices (VADs) are employed to support these cases while awaiting cardiac recovery or transplantation, or in some cases as destination therapy. While left ventricular assist device (LVAD) therapy alone is effective in many instances, up to 50% of LVAD recipients demonstrate clinically significant postoperative right ventricular failure and potentially need a biventricular assist device (BiVAD). In these cases, the BiVAD can effectively support both sides of the failing heart. This article presents a technical review of BiVADs, both clinically applied and under development. The BiVADs which have been used clinically are predominantly first generation, pulsatile, and paracorporeal systems that are bulky and prone to device failure, thrombus formation, and infection. While they have saved many lives, they generally necessitate a large external pneumatic driver which inhibits normal movement and quality of life for many patients. In an attempt to alleviate these issues, several smaller, implantable second and third generation devices that use either immersed mechanical blood bearings or hydrodynamic/magnetic levitation systems to support a rotating impeller are under development or in the early stages of clinical use. Although these rotary devices may offer a longer term, completely implantable option for patients with biventricular failure, their control strategies need to be refined to compete with the inherent volume balancing ability of the first generation devices. The BiVAD systems potentially offer an improved quality of life to patients with total heart failure, and thus a viable alternative to heart transplantation is anticipated with continued development.
- 8 July 2011
- Published by Springer Nature in Annals of Biomedical Engineering
- Vol. 39 (9) , 2313-2328
Biventricular Assist Devices: A Technical Review
The optimal treatment option for end stage heart failure is transplantation; however, the shortage of donor organs necessitates alternative treatment strategies such as mechanical circulatory assistance. Ventricular assist devices (VADs) are employed to support these cases while awaiting cardiac recovery or transplantation, or in some cases as destination therapy. While left ventricular assist device (LVAD) therapy alone is effective in many instances, up to 50% of LVAD recipients demonstrate clinically significant postoperative right ventricular failure and potentially need a biventricular assist device (BiVAD). In these cases, the BiVAD can effectively support both sides of the failing heart. This article presents a technical review of BiVADs, both clinically applied and under development. The BiVADs which have been used clinically are predominantly first generation, pulsatile, and paracorporeal systems that are bulky and prone to device failure, thrombus formation, and infection. While they have saved many lives, they generally necessitate a large external pneumatic driver which inhibits normal movement and quality of life for many patients. In an attempt to alleviate these issues, several smaller, implantable second and third generation devices that use either immersed mechanical blood bearings or hydrodynamic/magnetic levitation systems to support a rotating impeller are under development or in the early stages of clinical use. Although these rotary devices may offer a longer term, completely implantable option for patients with biventricular failure, their control strategies need to be refined to compete with the inherent volume balancing ability of the first generation devices. The BiVAD systems potentially offer an improved quality of life to patients with total heart failure, and thus a viable alternative to heart transplantation is anticipated with continued development.
- 1 August 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2010 (1094687X) , 6154-6157
Pediatric Obstructive Sleep Apnea assessment using pulse oximetry and dual RIP bands
The diagnosis of Obstructive Sleep Apnea (OSA) in children presents a challenging diagnostic problem given the high prevalence (2-3%), the resource intensity of the overnight polysomnography investigation, and the realisation that OSA poses a serious threat to the healthy growth and development of children. Previous attempts to develop OSA diagnostic systems using home pulse oximetry studies have failed to meet the accuracy requirements - particularly the low false normal rate (FNR) - required for a pre-PSG screening test. Thus the aim of this study is to investigate the feasibility of an OSA severity diagnostic system based on both oximetry and dual respiratory inductance plethysmography (RIP) bands. A total of 90 PSG studies (30 each of normal, mild/moderate and severe OSA) were retrospectively analyzed. Quantifications of oxygen desaturations (S), respiratory events (E) and heart rate arousals (A) were calculated and extracted and an empirical rule-based SEA classifier model for normal, mild/moderate and severe OSA defined and developed. In addition, an automated classifier using a decision tree algorithm was trained and tested using a 10-fold cross-validation. The empirical classification system showed a correct classification rate (CCR) of 0.83 (Cohen's Kappa κ=0.81, FNR=0.08), and the decision tree classifier achieved a CCR of 0.79 (κ=0.73, FNR=0.08) when compared to gold standard PSG assessment. The relatively high CCR, and low FNR indicate that a OSA severity system based on dual RIP and oximetry is feasible for application as a pre-PSG screening tool.
- 1 August 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2010 (1094687X) , 6154-6157
Pediatric Obstructive Sleep Apnea assessment using pulse oximetry and dual RIP bands
The diagnosis of Obstructive Sleep Apnea (OSA) in children presents a challenging diagnostic problem given the high prevalence (2-3%), the resource intensity of the overnight polysomnography investigation, and the realisation that OSA poses a serious threat to the healthy growth and development of children. Previous attempts to develop OSA diagnostic systems using home pulse oximetry studies have failed to meet the accuracy requirements - particularly the low false normal rate (FNR) - required for a pre-PSG screening test. Thus the aim of this study is to investigate the feasibility of an OSA severity diagnostic system based on both oximetry and dual respiratory inductance plethysmography (RIP) bands. A total of 90 PSG studies (30 each of normal, mild/moderate and severe OSA) were retrospectively analyzed. Quantifications of oxygen desaturations (S), respiratory events (E) and heart rate arousals (A) were calculated and extracted and an empirical rule-based SEA classifier model for normal, mild/moderate and severe OSA defined and developed. In addition, an automated classifier using a decision tree algorithm was trained and tested using a 10-fold cross-validation. The empirical classification system showed a correct classification rate (CCR) of 0.83 (Cohen's Kappa κ=0.81, FNR=0.08), and the decision tree classifier achieved a CCR of 0.79 (κ=0.73, FNR=0.08) when compared to gold standard PSG assessment. The relatively high CCR, and low FNR indicate that a OSA severity system based on dual RIP and oximetry is feasible for application as a pre-PSG screening tool.
- 1 August 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2010 (1094687X) , 426-429
Adaptive multi-infusion decision support for the multivariable circulatory management of critically ill patients
We have developed a novel adaptive multi-infusion advisory system for circulatory management of critically ill patients which co-ordinates infusion adjustments to ensure safe trajectories. This system should reduce patient hospital stay and improve patient outcome by enhancing the quality of patient circulatory control; alleviating the clinical cognitive load, giving staff more time for direct patient care, while also reducing infusion adjustment errors. We have applied three derived circulatory variables which relate to the three main types of cardiovascular infusions (inotropic, vasoactive and fluid). A lumped parameter steady flow model of the human circulatory system and the effects of cardiovascular infusions was constructed for algorithm development, clinical experts providing feedback on a representative test set of simulated patients in circulatory shock. Independent self-learning fuzzy logic controllers (SLFLC) were found to give good adaptation to variable patient infusion sensitivities. A supervisory, rule-based module co-ordinates infusion adjustments to ensure safe circulatory trajectories. Monitoring of manual infusion adjustments allows timely advice and also a critiquing capability which can train junior staff and reduce infusion adjustment errors. A physical mock circulatory loop was used to construct and test our physical advisory system. Preliminary clinical results show good clinical utility of our adaptive multi-infusion advisory system.
- 1 August 2010
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2010 (1094687X) , 426-429
Adaptive multi-infusion decision support for the multivariable circulatory management of critically ill patients
We have developed a novel adaptive multi-infusion advisory system for circulatory management of critically ill patients which co-ordinates infusion adjustments to ensure safe trajectories. This system should reduce patient hospital stay and improve patient outcome by enhancing the quality of patient circulatory control; alleviating the clinical cognitive load, giving staff more time for direct patient care, while also reducing infusion adjustment errors. We have applied three derived circulatory variables which relate to the three main types of cardiovascular infusions (inotropic, vasoactive and fluid). A lumped parameter steady flow model of the human circulatory system and the effects of cardiovascular infusions was constructed for algorithm development, clinical experts providing feedback on a representative test set of simulated patients in circulatory shock. Independent self-learning fuzzy logic controllers (SLFLC) were found to give good adaptation to variable patient infusion sensitivities. A supervisory, rule-based module co-ordinates infusion adjustments to ensure safe circulatory trajectories. Monitoring of manual infusion adjustments allows timely advice and also a critiquing capability which can train junior staff and reduce infusion adjustment errors. A physical mock circulatory loop was used to construct and test our physical advisory system. Preliminary clinical results show good clinical utility of our adaptive multi-infusion advisory system.