Naoki Suzuki
Research Subjects
Research Interests
Naoki Suzuki has a total of 78 co-authors. Here are the top co-authors by number of shared publications:
Asaki Hattori
Institute for High Dimensional Medical Imaging, The Jikei University School of Medicine
39 shared publications- Yoshito Otake
Institute for High Dimensional Medical Imaging, Jikei University School of Medicine, Tokyo, Japan
15 shared publications Shigeyuki Suzuki
10 shared publications- Mitsuhiro Hayashibe
Tohoku University
9 shared publications - Takumi Ogawa
Department of Fixed Prosthodontics, Tsurumi University School of Dental Medicine
9 shared publications - Akihiko Uchiyama
Graduate School of Integrative Bioscience and Biomedical Engineering, Waseda University, Tokyo, 169‐8555 Japan
7 shared publications
Latest Publications
- Open Access
- 31 January 2025
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 107 (6) , 558-564
Dysfunction of the Windlass Mechanism Is Associated with Hallux Rigidus
Background: The cause of hallux rigidus remains controversial. However, it is assumed that dysfunction of the windlass mechanism and metatarsus primus elevatus play a role in the pathology. Three-dimensional (3D) computed tomography (CT) imaging is ideal for analysis of movements of the foot, which involve 3D and rotational motion. The purpose of the present study was to compare the windlass mechanism in healthy normal feet with that in feet with hallux rigidus by 3D CT imaging. Methods: A total of 17 feet with hallux rigidus and 21 normal feet were selected. Hallux rigidus was classified as grade 1 or 2 with use of the Coughlin and Shurnas system. CT imaging was performed during weight-bearing and non-weight-bearing with the first metatarsophalangeal joint in a neutral position or in 30° of dorsiflexion. We measured the rotation of each joint and the height of the navicular during dorsiflexion and weight-bearing. We also compared changes in the tarsometatarsal joint and metatarsus primus elevatus in the neutral position between the non-weight-bearing and weight-bearing conditions. Results: During dorsiflexion, there were significant differences between the 2 groups in eversion and adduction at the talonavicular and talocalcaneal joints (p < 0.05), with less movement of bones in the hallux rigidus group. There was a significantly greater increase in height of the navicular in the control group than in the hallux rigidus group (1.2 ± 0.6 mm versus 0.7 ± 0.6 mm; p = 0.02). There was also a significant difference in metatarsus primus elevatus during the non-weight-bearing and weight-bearing conditions (p < 0.01). Conclusions: Hallux rigidus restricts the movement of the Chopart joint and hindfoot associated with dorsiflexion of the first metatarsophalangeal joint, suggesting an association between hallux rigidus and windlass mechanism dysfunction. Level of Evidence: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 31 January 2025
- Published by Wolters Kluwer Health in Journal of Bone and Joint Surgery
- Vol. 107 (6) , 558-564
Open AccessDysfunction of the Windlass Mechanism Is Associated with Hallux Rigidus
Background: The cause of hallux rigidus remains controversial. However, it is assumed that dysfunction of the windlass mechanism and metatarsus primus elevatus play a role in the pathology. Three-dimensional (3D) computed tomography (CT) imaging is ideal for analysis of movements of the foot, which involve 3D and rotational motion. The purpose of the present study was to compare the windlass mechanism in healthy normal feet with that in feet with hallux rigidus by 3D CT imaging. Methods: A total of 17 feet with hallux rigidus and 21 normal feet were selected. Hallux rigidus was classified as grade 1 or 2 with use of the Coughlin and Shurnas system. CT imaging was performed during weight-bearing and non-weight-bearing with the first metatarsophalangeal joint in a neutral position or in 30° of dorsiflexion. We measured the rotation of each joint and the height of the navicular during dorsiflexion and weight-bearing. We also compared changes in the tarsometatarsal joint and metatarsus primus elevatus in the neutral position between the non-weight-bearing and weight-bearing conditions. Results: During dorsiflexion, there were significant differences between the 2 groups in eversion and adduction at the talonavicular and talocalcaneal joints (p < 0.05), with less movement of bones in the hallux rigidus group. There was a significantly greater increase in height of the navicular in the control group than in the hallux rigidus group (1.2 ± 0.6 mm versus 0.7 ± 0.6 mm; p = 0.02). There was also a significant difference in metatarsus primus elevatus during the non-weight-bearing and weight-bearing conditions (p < 0.01). Conclusions: Hallux rigidus restricts the movement of the Chopart joint and hindfoot associated with dorsiflexion of the first metatarsophalangeal joint, suggesting an association between hallux rigidus and windlass mechanism dysfunction. Level of Evidence: Prognostic Level III. See Instructions for Authors for a complete description of levels of evidence.
- 1 December 2021
- Published by Springer Nature
- p. 373-380
4D—Four-Dimensional Dynamic Images: Principle and Future Application
- 1 December 2021
- Published by Springer Nature
- p. 373-380
4D—Four-Dimensional Dynamic Images: Principle and Future Application
- 1 January 2016
- Vol. 220, 396-402
Development of Four Dimensional Human Model that Enables Deformation of Skin, Organs and Blood Vessel System During Body Movement - Visualizing Movements of the Musculoskeletal System.
We constructed a four dimensional human model that is able to visualize the structure of a whole human body, including the inner structures, in real-time to allow us to analyze human dynamic changes in the temporal, spatial and quantitative domains. To verify whether our model was generating changes according to real human body dynamics, we measured a participant's skin expansion and compared it to that of the model conducted under the same body movement. We also made a contribution to the field of orthopedics, as we were able to devise a display method that enables the observer to more easily observe the changes made in the complex skeletal muscle system during body movements, which in the past were difficult to visualize.
- 1 January 2016
- Vol. 220, 396-402
Development of Four Dimensional Human Model that Enables Deformation of Skin, Organs and Blood Vessel System During Body Movement - Visualizing Movements of the Musculoskeletal System.
We constructed a four dimensional human model that is able to visualize the structure of a whole human body, including the inner structures, in real-time to allow us to analyze human dynamic changes in the temporal, spatial and quantitative domains. To verify whether our model was generating changes according to real human body dynamics, we measured a participant's skin expansion and compared it to that of the model conducted under the same body movement. We also made a contribution to the field of orthopedics, as we were able to devise a display method that enables the observer to more easily observe the changes made in the complex skeletal muscle system during body movements, which in the past were difficult to visualize.
- 10 December 2015
- Published by Springer Nature
- p. 80-91
Development of 4D Human Body Model that Enables Deformation of Skin, Organ and Blood Vessel According to Dynamic Change
- 10 December 2015
- Published by Springer Nature
- p. 80-91
Development of 4D Human Body Model that Enables Deformation of Skin, Organ and Blood Vessel According to Dynamic Change
- 12 August 2015
- Published by ASME International in Journal of Medical Devices
- Vol. 9 (4) , 044506
Ability of a Novel Foot and Ankle Loading Device to Reproduce Loading Conditions in the Standing Position During Computed Tomography
To describe a loading device, we created for use with current computed tomography (CT) scanners and to evaluate its ability to reproduce loading conditions. Ten feet of five healthy volunteers (three men and two women) with no history of foot or ankle disorders and no foot pain were studied. Subjects lay on the device in the supine position with the legs extended and ankles in a neutral position. An axial load equivalent to their body weight was applied to the soles. A foot scan measured plantar contact area, plantar pressure, and the center of pressure under standing and weight-bearing conditions. Differences between measurements were assessed using the paired t test with a two-sided significance of 5%. No subjects complained of pain or discomfort during loading. Weight-bearing measurements varied from standing measurements as follows: plantar contact area, −4.15 cm2; contact % (forefoot/midfoot/hindfoot), −0.61%/−0.17%/0.79%; plantar pressure, −1.47 N/cm2/−0.49 N/cm2/3.7 N/cm2 (6.40 N/cm2 overall); and center of pressure location (anterior–posterior/medial–lateral), 0.88%/0.36%. With the numbers available, no significant difference could be detected for any tested items. We were able to produce load distributions and intensities resembling standing conditions. Thus, the standing condition can be well produced on CT images if our device is used. Furthermore, images can be compared with those of healthy individuals to yield useful information for elucidating the pathophysiology and pathology of foot disorders.
- 12 August 2015
- Published by ASME International in Journal of Medical Devices
- Vol. 9 (4) , 044506
Ability of a Novel Foot and Ankle Loading Device to Reproduce Loading Conditions in the Standing Position During Computed Tomography
To describe a loading device, we created for use with current computed tomography (CT) scanners and to evaluate its ability to reproduce loading conditions. Ten feet of five healthy volunteers (three men and two women) with no history of foot or ankle disorders and no foot pain were studied. Subjects lay on the device in the supine position with the legs extended and ankles in a neutral position. An axial load equivalent to their body weight was applied to the soles. A foot scan measured plantar contact area, plantar pressure, and the center of pressure under standing and weight-bearing conditions. Differences between measurements were assessed using the paired t test with a two-sided significance of 5%. No subjects complained of pain or discomfort during loading. Weight-bearing measurements varied from standing measurements as follows: plantar contact area, −4.15 cm2; contact % (forefoot/midfoot/hindfoot), −0.61%/−0.17%/0.79%; plantar pressure, −1.47 N/cm2/−0.49 N/cm2/3.7 N/cm2 (6.40 N/cm2 overall); and center of pressure location (anterior–posterior/medial–lateral), 0.88%/0.36%. With the numbers available, no significant difference could be detected for any tested items. We were able to produce load distributions and intensities resembling standing conditions. Thus, the standing condition can be well produced on CT images if our device is used. Furthermore, images can be compared with those of healthy individuals to yield useful information for elucidating the pathophysiology and pathology of foot disorders.
- 1 January 2014
- Vol. 196, 404-8
Development of AR Surgical Navigation Systems for Multiple Surgical Regions.
The purpose of our research is to develop surgical navigation systems to enhance surgical safety. Our systems make use of augmented reality technology to superimpose, on the surgery screen on a real time basis, patients' organ models reconstructed in 3D from their X-ray CT data taken before surgery. By doing so, the systems display anatomical risk materials, tumors and blood vessels which surgeons cannot see with their naked eyes. This will in turn lead to surgeons intuitively grasping the inner structures of the operational fields. We so far have been developing navigation systems that can conduct surgeries in various fields. The basic structure of the navigation systems are the same. The navigation systems uses different peripheral equipment and different methods to display navigation images which best meet the demands of each type of surgery. In this thesis, we report on our navigation systems for 2 types of surgery - endoscopic sinus surgery and hepatobilialy-pancreatic surgery.
- 1 January 2014
- Vol. 196, 404-8
Development of AR Surgical Navigation Systems for Multiple Surgical Regions.
The purpose of our research is to develop surgical navigation systems to enhance surgical safety. Our systems make use of augmented reality technology to superimpose, on the surgery screen on a real time basis, patients' organ models reconstructed in 3D from their X-ray CT data taken before surgery. By doing so, the systems display anatomical risk materials, tumors and blood vessels which surgeons cannot see with their naked eyes. This will in turn lead to surgeons intuitively grasping the inner structures of the operational fields. We so far have been developing navigation systems that can conduct surgeries in various fields. The basic structure of the navigation systems are the same. The navigation systems uses different peripheral equipment and different methods to display navigation images which best meet the demands of each type of surgery. In this thesis, we report on our navigation systems for 2 types of surgery - endoscopic sinus surgery and hepatobilialy-pancreatic surgery.
- 1 January 2014
- Vol. 196, 409-15
A concept for overlaid-type surgical navigation system with organ modification functions using non-contact type surface measurement.
Surgical navigation systems are clinically applied in cerebral and otological surgeries but they are only used in parts with minimum surgical transformation in regions in which the organs largely transform, such as in the abdomen. Therefore, we here propose a concept of a surgical navigation system that could be used in the regions such as liver, which largely transforms itself during surgery. We consider a method that measures the changes in the organ surface configuration during surgery and estimates the changes in the tumor and blood vessel structure following the transformation of the organ surface. We also report on the necessary disposition of each process of this method, especially on the basic examination of the organ transformation.
- 1 January 2014
- Vol. 196, 409-15
A concept for overlaid-type surgical navigation system with organ modification functions using non-contact type surface measurement.
Surgical navigation systems are clinically applied in cerebral and otological surgeries but they are only used in parts with minimum surgical transformation in regions in which the organs largely transform, such as in the abdomen. Therefore, we here propose a concept of a surgical navigation system that could be used in the regions such as liver, which largely transforms itself during surgery. We consider a method that measures the changes in the organ surface configuration during surgery and estimates the changes in the tumor and blood vessel structure following the transformation of the organ surface. We also report on the necessary disposition of each process of this method, especially on the basic examination of the organ transformation.
- 1 January 2013
- Vol. 184, 424-30
Formulation of wire control mechanism for surgical robot to create virtual reality environment aimed at conducting surgery inside the body.
We here report on the process of developing a surgical robot that can conduct operation "going inside the body without spreading the operational region". The endoscopic robot that we are developing now has a flexible cylindrical body with functions of a set of human arms at the tip and also with vision and haptic sense functions. We evaluated necessary technology factor to complete this robot into categories such as, transmission of energy, adaptation to insides of the body.
- 1 January 2013
- Vol. 184, 424-30
Formulation of wire control mechanism for surgical robot to create virtual reality environment aimed at conducting surgery inside the body.
We here report on the process of developing a surgical robot that can conduct operation "going inside the body without spreading the operational region". The endoscopic robot that we are developing now has a flexible cylindrical body with functions of a set of human arms at the tip and also with vision and haptic sense functions. We evaluated necessary technology factor to complete this robot into categories such as, transmission of energy, adaptation to insides of the body.
- 1 January 2012
- Vol. 173, 166-70
Training system for NOTES and SPS surgery robot that enables spatiotemporal retrospective analysis of the training process.
Within the digestive organ surgery robot R&D project, our research team aims to develop a surgical robot training device with an interface identical to that of the actual device. The training device uses an organ model that changes shape in real time to train operators to grab, cut open, and cut off soft tissues and close wounds using the actual device. To increase the effectiveness of the training device, we added functions to save the movements of the robot in training and changes in the operation field. By recreating the situation during training, we were able to analyze in four dimensions (4D) various changes in the operation field that the operator cannot see during training. This new function not only enabled us to analyze the contents of the training in detail, but also to report any problems in development and design of the actual device.
- 1 January 2012
- Vol. 173, 166-70
Training system for NOTES and SPS surgery robot that enables spatiotemporal retrospective analysis of the training process.
Within the digestive organ surgery robot R&D project, our research team aims to develop a surgical robot training device with an interface identical to that of the actual device. The training device uses an organ model that changes shape in real time to train operators to grab, cut open, and cut off soft tissues and close wounds using the actual device. To increase the effectiveness of the training device, we added functions to save the movements of the robot in training and changes in the operation field. By recreating the situation during training, we were able to analyze in four dimensions (4D) various changes in the operation field that the operator cannot see during training. This new function not only enabled us to analyze the contents of the training in detail, but also to report any problems in development and design of the actual device.
- 1 January 2012
- Vol. 173, 506-11
System development for unrestrictive view and 4D shape acquisition in abdominal cavity operation using virtual space.
Laparoscopic surgery has been used for various areas of abdominal cavity. However, the laparoscope has limitation of its field of view and mobility. Our aim is to develop a new video camera system that acquires multiple viewpoints in the abdominal cavity. We designed a camera array that consisted of eight small camera modules. The camera array can change its shape so that it can be inserted into the abdominal cavity through trocar. Surgeon can change the viewpoint by switching camera output without physically moving the camera. Using eight camera's images, we also tried to reconstruct 3D textured shape of the surgery field.
- 1 January 2012
- Vol. 173, 506-11
System development for unrestrictive view and 4D shape acquisition in abdominal cavity operation using virtual space.
Laparoscopic surgery has been used for various areas of abdominal cavity. However, the laparoscope has limitation of its field of view and mobility. Our aim is to develop a new video camera system that acquires multiple viewpoints in the abdominal cavity. We designed a camera array that consisted of eight small camera modules. The camera array can change its shape so that it can be inserted into the abdominal cavity through trocar. Surgeon can change the viewpoint by switching camera output without physically moving the camera. Using eight camera's images, we also tried to reconstruct 3D textured shape of the surgery field.