Takumi Ogawa
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Takumi Ogawa has a total of 66 co-authors. Here are the top co-authors by number of shared publications:
Shunji Fukushima
15 shared publications- Yuko Shigeta
Department of Fixed Prosthodontics, School of Dental Medicine, Tsurumi University, Yokohama, Japan
12 shared publications Asaki Hattori
11 shared publications- Naoki Suzuki
The Jikei University School of Medicine
9 shared publications - Tomoko Ikawa
Department of Fixed Prosthodontics, Tsurumi University School of Dental Medicine
8 shared publications Rio Hirabayashi
Department of Fixed Prosthodontics, Tsurumi University School of Dental Medicine
5 shared publications
Latest Publications
- Open Access
- 2 May 2019
- Published by Springer Nature in BMC Oral Health
- Vol. 19 (1) , 1-9
Consistency of supplied food and dentition status of the elderly in residential care homes
The association between oral health and malnutrition has been investigated in detail. The nutrition of elderly subjects in residential care homes is determined by caregivers, dietitians or nutritionists and managed by changing the consistency of their supplied food. However, few reports have described the relationship between oral condition and supplied food consistency. The objective of this study was to determine dentition status and care levels that correlate with supplied food consistency among elderly residents of care facilities. In addition, we estimated the care level at which ordinary food consistency can be supplied by caregivers who cannot diagnose dental status. Several factors, including dentition, wearing removable dentures, meals categorized as ordinary or processed (sliced, mashed, or liquefied), and care levels according to the Japanese standardized care-needs certification system were investigated in 276 elderly residents (male, n = 56; female, n = 220; mean age, 87.68 ± 5.94 years) of 12 fee-based care facilities. The results of this study showed that care levels were significantly correlated with the consistency of the food supplied to the residents. When supplied food consistency was categorized as ordinary or processed, the number of remaining teeth and the number of tooth contact pairs, either natural or artificial, were statistically significant. From logistic regression analysis, it was determined that the numbers of tooth contact pairs were statistically significant among residents requiring high levels of care. The number of tooth contact pairs, either natural or artificial, was one of the contributing factors for deciding supplied food consistency among elderly residents of care facilities. Elderly residents requiring less than care level 3 should have ordinary meals.
- 2 May 2019
- Published by Springer Nature in BMC Oral Health
- Vol. 19 (1) , 1-9
Open AccessConsistency of supplied food and dentition status of the elderly in residential care homes
The association between oral health and malnutrition has been investigated in detail. The nutrition of elderly subjects in residential care homes is determined by caregivers, dietitians or nutritionists and managed by changing the consistency of their supplied food. However, few reports have described the relationship between oral condition and supplied food consistency. The objective of this study was to determine dentition status and care levels that correlate with supplied food consistency among elderly residents of care facilities. In addition, we estimated the care level at which ordinary food consistency can be supplied by caregivers who cannot diagnose dental status. Several factors, including dentition, wearing removable dentures, meals categorized as ordinary or processed (sliced, mashed, or liquefied), and care levels according to the Japanese standardized care-needs certification system were investigated in 276 elderly residents (male, n = 56; female, n = 220; mean age, 87.68 ± 5.94 years) of 12 fee-based care facilities. The results of this study showed that care levels were significantly correlated with the consistency of the food supplied to the residents. When supplied food consistency was categorized as ordinary or processed, the number of remaining teeth and the number of tooth contact pairs, either natural or artificial, were statistically significant. From logistic regression analysis, it was determined that the numbers of tooth contact pairs were statistically significant among residents requiring high levels of care. The number of tooth contact pairs, either natural or artificial, was one of the contributing factors for deciding supplied food consistency among elderly residents of care facilities. Elderly residents requiring less than care level 3 should have ordinary meals.
- 1 January 2014
- Published by Japanese Society of Stomatognathic Function in The Journal of Japanese Society of Stomatognathic Function
- Vol. 21 (1) , 58-59
Reproduction of Occlusal Contacts on a 3D Model of Dentition
- 1 January 2014
- Published by Japanese Society of Stomatognathic Function in The Journal of Japanese Society of Stomatognathic Function
- Vol. 21 (1) , 58-59
Reproduction of Occlusal Contacts on a 3D Model of Dentition
- 1 March 2013
- Vol. 130 (3) , 203-11
Soft palate length and upper airway relationship in OSA and non-OSA subjects.
The narrowest area of the airway between the posterior nasal opening and the epiglottis is usually located in the retro palatal area. Many consider this the most likely site of airway obstruction during an obstructive sleep apnea (OSA) event. The aim of this study was to investigate the differences in soft palate and airway length between OSA and non-OSA patients. In this study, we analyzed the ratio of the soft palate and the upper airway length in 45 consecutive patients. Twenty-five had an Apnea-Hypoapnea Index of more than 5 events per hour and were classified in the OSA group (male, 19; female, 6). These patients were compared with 20 normal controls (male, 12; female, 8). Controls who complained of snoring did have sleep studies (n = 5). The other fifteen controls were clinically asymptomatic and did not have sleep studies. Medical computed tomography scans were taken to determine the length of the upper airway and the soft palate length measured in the midsagittal image. Soft palate length was significantly larger in OSA patients compared to controls (p = 0.009), and in men compared to women (p = 0.002). However, there were no differences in airway length. The soft palate length, as a percent of oropharyngeal airway length, was significantly larger in OSA patients compared to controls (p = < 0.0001) and in men compared to women (p = 0.02). Soft palate length increases significantly with age by 0.3 mm per year in males (after adjustment for body mass index (BMI) and OSA). Soft palate length as a percent of airway length is larger in OSA patients and increases significantly with BMI in males only after adjusting for age. In this study, OSA patients had a longer soft palate in proportion to their oropharyngeal airway compared to controls as well as men compared to women. This proportion could be used for identifying patients at risk for OSA in combination with age.
- 1 March 2013
- Vol. 130 (3) , 203-11
Soft palate length and upper airway relationship in OSA and non-OSA subjects.
The narrowest area of the airway between the posterior nasal opening and the epiglottis is usually located in the retro palatal area. Many consider this the most likely site of airway obstruction during an obstructive sleep apnea (OSA) event. The aim of this study was to investigate the differences in soft palate and airway length between OSA and non-OSA patients. In this study, we analyzed the ratio of the soft palate and the upper airway length in 45 consecutive patients. Twenty-five had an Apnea-Hypoapnea Index of more than 5 events per hour and were classified in the OSA group (male, 19; female, 6). These patients were compared with 20 normal controls (male, 12; female, 8). Controls who complained of snoring did have sleep studies (n = 5). The other fifteen controls were clinically asymptomatic and did not have sleep studies. Medical computed tomography scans were taken to determine the length of the upper airway and the soft palate length measured in the midsagittal image. Soft palate length was significantly larger in OSA patients compared to controls (p = 0.009), and in men compared to women (p = 0.002). However, there were no differences in airway length. The soft palate length, as a percent of oropharyngeal airway length, was significantly larger in OSA patients compared to controls (p = < 0.0001) and in men compared to women (p = 0.02). Soft palate length increases significantly with age by 0.3 mm per year in males (after adjustment for body mass index (BMI) and OSA). Soft palate length as a percent of airway length is larger in OSA patients and increases significantly with BMI in males only after adjusting for age. In this study, OSA patients had a longer soft palate in proportion to their oropharyngeal airway compared to controls as well as men compared to women. This proportion could be used for identifying patients at risk for OSA in combination with age.
- Open Access
- 1 January 2013
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 32 (1) , 144-149
Influence of filler on bite impression material in transillumination method for occlusal examination
The purpose of this present study was to investigate the influence of material filler and RGB values' fluctuation on creating a calibration curve, which indicates the relationship between material thickness and transmitted light brightness using the transillumination method. Creating the calibration curves were carried out through the following three methods; 1) the conventional method creates the calibration curve with a formula of thickness, 2) the maximum value method, with samples of a specified thickness, and 3) the actual value method, with a microscope. Furthermore, the reliability of each curve was verified via scanned artificial tooth data. In addition, the characteristics of light decrement were investigated. From our results, it was suggested that the filler diameter must be considered when the calibration curve is created using the bite impression material with a filler. In addition, it was suggested that the RGB values' fluctuation did not influence the calibration curve.
- 1 January 2013
- Published by Japanese Society for Dental Materials and Devices in Dental Materials Journal
- Vol. 32 (1) , 144-149
Open AccessInfluence of filler on bite impression material in transillumination method for occlusal examination
The purpose of this present study was to investigate the influence of material filler and RGB values' fluctuation on creating a calibration curve, which indicates the relationship between material thickness and transmitted light brightness using the transillumination method. Creating the calibration curves were carried out through the following three methods; 1) the conventional method creates the calibration curve with a formula of thickness, 2) the maximum value method, with samples of a specified thickness, and 3) the actual value method, with a microscope. Furthermore, the reliability of each curve was verified via scanned artificial tooth data. In addition, the characteristics of light decrement were investigated. From our results, it was suggested that the filler diameter must be considered when the calibration curve is created using the bite impression material with a filler. In addition, it was suggested that the RGB values' fluctuation did not influence the calibration curve.
- 1 January 2011
- Vol. 163, 239-41
Design for functional occlusal surface of CAD/CAM crown using VR articulator.
In this present study, we introduce an approach that utilizes the VR articulator to mimic lateral excursions and design a functional occlusal surface. We then take the resultant occlusal surface from this approach and compare it with a conventional method. As a result, we developed a novel CAD/CAM system which can render a functional occlusal surface, via a VR articulator. The marginal fit and occlusion in our CAD/CAM crown was sufficient to apply to the clinic.
- 1 January 2011
- Vol. 163, 239-41
Design for functional occlusal surface of CAD/CAM crown using VR articulator.
In this present study, we introduce an approach that utilizes the VR articulator to mimic lateral excursions and design a functional occlusal surface. We then take the resultant occlusal surface from this approach and compare it with a conventional method. As a result, we developed a novel CAD/CAM system which can render a functional occlusal surface, via a VR articulator. The marginal fit and occlusion in our CAD/CAM crown was sufficient to apply to the clinic.
- 1 January 2011
- Vol. 163, 261-3
Influence of metal artifacts on the creation of individual 3D cranio-mandibular models.
In our clinic, the four-dimensional analysis of mandibular movement has mainly been used to diagnose jaw function disorders. In present, we are considering its application for patients with occlusal issues. Consequently, an improvement in system accuracy is required. However, metal artifacts cause distortions in the 3D-cranio-mandibular model construction process, which leads to accuracy concerns. The purpose of this present study was to grasp the accuracy differences caused by the oral metal restorations in reconstructed 3D-cranio-mandibular models from CT data, and scanned dentition models. The accuracy of the reconstruction was confirmed from comparing the occlusal contacts in VR space and real space. The VR contact areas in the dry skulls without and moderate restoration showed a close similarity to real occlusal contacts. However, the VR contact areas in the dry skull with numerous restorations was not similar to the real contacts. From these results, it is considered that metal artifacts decrease the accuracy of model reconstruction.
- 1 January 2011
- Vol. 163, 261-3
Influence of metal artifacts on the creation of individual 3D cranio-mandibular models.
In our clinic, the four-dimensional analysis of mandibular movement has mainly been used to diagnose jaw function disorders. In present, we are considering its application for patients with occlusal issues. Consequently, an improvement in system accuracy is required. However, metal artifacts cause distortions in the 3D-cranio-mandibular model construction process, which leads to accuracy concerns. The purpose of this present study was to grasp the accuracy differences caused by the oral metal restorations in reconstructed 3D-cranio-mandibular models from CT data, and scanned dentition models. The accuracy of the reconstruction was confirmed from comparing the occlusal contacts in VR space and real space. The VR contact areas in the dry skulls without and moderate restoration showed a close similarity to real occlusal contacts. However, the VR contact areas in the dry skull with numerous restorations was not similar to the real contacts. From these results, it is considered that metal artifacts decrease the accuracy of model reconstruction.
- 1 January 2011
- Vol. 163, 422-4
Virtual reality image applications for treatment planning in prosthodontic dentistry.
For successful occlusal reconstruction, the prosthodontists must take several points into consideration, such as those involving issues with functional and morphological findings and aesthetics. They then must unify this information into a coherent treatment plan. In this present study we focused on prosthodontic treatment and investigated how treatment planning and simulation could be applied to two cases. The personal occlusion condition can be reproduced on the virtual articulator in VR space. In addition, various simulations can be performed that involve prosthetesis design.
- 1 January 2011
- Vol. 163, 422-4
Virtual reality image applications for treatment planning in prosthodontic dentistry.
For successful occlusal reconstruction, the prosthodontists must take several points into consideration, such as those involving issues with functional and morphological findings and aesthetics. They then must unify this information into a coherent treatment plan. In this present study we focused on prosthodontic treatment and investigated how treatment planning and simulation could be applied to two cases. The personal occlusion condition can be reproduced on the virtual articulator in VR space. In addition, various simulations can be performed that involve prosthetesis design.
- 1 January 2011
- Vol. 163, 713-5
Clinical performance of dental fiberscope image guided system for endodontic treatment.
We developed a dental fiberscope that can be navigated. As a result we are able to better grasp the device position relative to the teeth, aiming at the lesion more precisely. However, the device position and the precise target setting were difficult to consistently ascertain. The aim of this study is to navigate the position of tip of the dental fiberscope fiber in the root canal with our navigation system. A 3D tooth model was made from the raw dental CT data. In addition, the optical position of the measurement device, OPTOTRAK system was used for registration of the 3D model and actual teeth position and to chase the scope movement. We developed exclusive software to unify information. We were subsequently able to precisely indicate the relation of the position between the device and the teeth on the 3D model in the monitor. This allowed us to aim at the lesion more precisely, as the revised endoscopic image matched the 3D model. The application of this endoscopic navigation system could increase the success rate for root canal treatments with recalcitrant lesion.
- 1 January 2011
- Vol. 163, 713-5
Clinical performance of dental fiberscope image guided system for endodontic treatment.
We developed a dental fiberscope that can be navigated. As a result we are able to better grasp the device position relative to the teeth, aiming at the lesion more precisely. However, the device position and the precise target setting were difficult to consistently ascertain. The aim of this study is to navigate the position of tip of the dental fiberscope fiber in the root canal with our navigation system. A 3D tooth model was made from the raw dental CT data. In addition, the optical position of the measurement device, OPTOTRAK system was used for registration of the 3D model and actual teeth position and to chase the scope movement. We developed exclusive software to unify information. We were subsequently able to precisely indicate the relation of the position between the device and the teeth on the 3D model in the monitor. This allowed us to aim at the lesion more precisely, as the revised endoscopic image matched the 3D model. The application of this endoscopic navigation system could increase the success rate for root canal treatments with recalcitrant lesion.
- 1 January 2009
- Vol. 142, 230-2
Designing artificial jaw joints (AJJs) in VR space for patients with rheumatoid arthritis.
In this present study, we will report on a case of a patient with sleep-disordered breathing (SDB). She suffered a condyle fracture that led to rheumatoid arthritis. Furthermore, we will review how we planned her treatment and designed her artificial jaw joints (AJJs) via 3D imaging in VR space.We decided the mandibular position based on the facial aesthetic line (E-line) and the occlusion. Then we designed her AJJs to comply with the translated mandible via 3D-modeling software.The upper airway obstruction is assumed to occur in the present case due to a pharyngeal obstruction, as in other patients with micrognathia or Sleep Apnea Syndrome. Therefore we had to take the sleep disorder into consideration in addition to occlusal management, based on experience with situations similar to this present case. Furthermore, designing a custom-made AJJs via a 3D model could prove insightful when it came to arranging the treatment plan of SDB patients.
- 1 January 2009
- Vol. 142, 230-2
Designing artificial jaw joints (AJJs) in VR space for patients with rheumatoid arthritis.
In this present study, we will report on a case of a patient with sleep-disordered breathing (SDB). She suffered a condyle fracture that led to rheumatoid arthritis. Furthermore, we will review how we planned her treatment and designed her artificial jaw joints (AJJs) via 3D imaging in VR space.We decided the mandibular position based on the facial aesthetic line (E-line) and the occlusion. Then we designed her AJJs to comply with the translated mandible via 3D-modeling software.The upper airway obstruction is assumed to occur in the present case due to a pharyngeal obstruction, as in other patients with micrognathia or Sleep Apnea Syndrome. Therefore we had to take the sleep disorder into consideration in addition to occlusal management, based on experience with situations similar to this present case. Furthermore, designing a custom-made AJJs via a 3D model could prove insightful when it came to arranging the treatment plan of SDB patients.
- 1 January 2008
- Vol. 132, 183-8
Evaluation of the simulation robot for mandibular movements with the patient-specific 3-dimensional plaster model and mandibular movement data: clinical application of the physical simulation robot.
We developed a multi-phase simulation system for patients with jaw deformity and dysfunction as a collaborate study between our departments. The intended application of the physical simulation robot was to evaluate its function based on well it quantitatively measured the movement of the individual patient. This physical simulation robot consists of a 6-degree-of-freedom robotic manipulator and a plaster model of patient-specific bone geometry. Each plaster model was mounted on the serial-articulated robotic manipulator. To establish the accuracy of the robot movement, the programmed movement of the robotic arm was validated using an optical tracking device. The results of the physical simulation robot corresponded with the data from the 4D analysis system. We could construct interactive relations between the 4D analysis system that was presented by virtual reality and the simulation robot which was constructed from physical simulation.
- 1 January 2008
- Vol. 132, 183-8
Evaluation of the simulation robot for mandibular movements with the patient-specific 3-dimensional plaster model and mandibular movement data: clinical application of the physical simulation robot.
We developed a multi-phase simulation system for patients with jaw deformity and dysfunction as a collaborate study between our departments. The intended application of the physical simulation robot was to evaluate its function based on well it quantitatively measured the movement of the individual patient. This physical simulation robot consists of a 6-degree-of-freedom robotic manipulator and a plaster model of patient-specific bone geometry. Each plaster model was mounted on the serial-articulated robotic manipulator. To establish the accuracy of the robot movement, the programmed movement of the robotic arm was validated using an optical tracking device. The results of the physical simulation robot corresponded with the data from the 4D analysis system. We could construct interactive relations between the 4D analysis system that was presented by virtual reality and the simulation robot which was constructed from physical simulation.