SDStephen R. Davies

Stephen R. Davies

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Stephen R. Davies has a total of 43 co-authors. Here are the top co-authors by number of shared publications:

  • Michael Moawad

    Australian Forensic Drug Laboratory National Measurement Institute North Ryde New South Wales Australia

    3 shared publications
  • Ronda F. Greaves

    Victorian Clinical Genetics Services , Murdoch Children’s Research Institute , Melbourne , VIC , Australia

    2 shared publications
  • B.D. Michael

    CRC Gray Lab., Northwood, UK

    1 shared publication
  • Benjamin Chan

    Australian Forensic Drug Laboratory National Measurement Institute North Ryde New South Wales Australia

    1 shared publication
  • Benjamin K. H. Chan

    Chemical Reference Materials, National Measurement Institute, P.O. Box 138, North Ryde, New South Wales, 1670, Australia

    1 shared publication
  • Benjamin K.H. Chan

    Chemical Reference Materials, National Measurement Institute, Riverside Corporate Park, North Ryde, Sydney, NSW, 2113, Australia

    1 shared publication

Latest Publications

  • Case study: Identification and characterization of N‐[2‐(dimethylamino)cyclohexyl]‐N‐methylnaphthalene‐2‐carboxamide, a regioisomer of the synthetic opioid U10

    by Michael Collins, David Brown, Stephen Davies, Benjamin Chan, Brendan Trotter, Michael Moawad, Karen Blakey, Lecinda Collins‐Brown


  • Influence of isotopically labeled internal standards on quantification of serum/plasma 17α-hydroxyprogesterone (17OHP) by liquid chromatography mass spectrometry

    by Tze Ping Loh, Chung Shun Ho, Michaela F. Hartmann, Rosita Zakaria, Clara Wai Shan Lo, Sjoerd van Den Berg, Yolanda B. de Rijke, Brian R. Cooke, Kirsten Hoad, Peter Graham, et al.

    Objectives: Our recent survey of 44 mass spectrometry laboratories across 17 countries identified variation in internal standard (IS) choice for the measurement of serum/plasma 17α-hydroxyprogesterone (17OHP) by liquid chromatography-tandem mass spectrometry (LC-MS/MS). The choice of IS may contribute to inter-method variations. This study evaluated the effect of two common isotopically labeled IS on the quantification of 17OHP by LC-MS/MS. Methods: Three collaborating LC-MS/MS laboratories from Asia, Europe and Australia, who routinely measure serum 17OHP, compared two IS, (1) IsoSciences carbon-13 labeled 17OHP-[2,3,4-13C3], and (2) IsoSciences deuterated 17OHP-[2,2,4,6,6,21,21,21-2H]. This was performed as part of their routine patient runs using their respective laboratory standard operating procedure. Results: The three laboratories measured 99, 89, 95 independent samples, respectively (up to 100 nmol/L) using the 13C- and 2H-labeled IS. The slopes of the Passing-Bablok regression ranged 0.98–1.00 (all 95% confidence interval [CI] estimates included the line of identity), and intercept of 13C- and 2H-labeled IS for 17OHP showed good agreement, and show no clinically significant bias when incorporated into the LC-MS/MS methods employed in the collaborating laboratories.


  • Comprehensive certification of a testosterone calibration standard facilitating the investigation of charged aerosol detection for the quantification of impurities of related structure

    by Stephen R Davies, Ponhatai Kankaew, Gregory James Tarrant, William A Donald, Ronda F Greaves

    Testosterone, an analyte of interest to medical testing laboratories, was purity assigned using a mass balance approach, to afford a certified value of 986 ± 3 mg g −1 with established metrological traceability to the SI unit for mass (kg). The gas chromatography with flame ionisation detection (GC-FID) analysis identified the thermal degradation of testosterone as a source of bias, and confirmed the other four impurities to be steroids of closely related structure through co-elution studies. Combined with measures of water, solvent and non-volatile residue the total purity was in agreement with that determined by the complementary quantitative NMR spectroscopy, providing a high level of confidence that the certified value was bias free. This sample was then used to investigate the applicability of charged aerosol detection to the assessment of high accuracy, low uncertainty organic purity determination of steroids. The relative peak areas of testosterone and impurities varied depending on the concentration of the test solution, precluding the direct conversion of peak areas to an accurate realization of the relative mass fraction. One impurity, androst-4,6-diene-17 β -ol-3-one, being overestimated by 155% compared to the GC-FID result. Charged aerosol detection (CAD) calibration curves established for testosterone and each impurity confirmed the detector response to vary by up to 30% at low levels (0–20 μg g −1 ), thereby challenging the view that the CAD response is independent of structure. Despite this, using the calibration curve of testosterone to quantify each impurity delivered a reasonable estimate of organic purity. The variations in detector response for each analyte were used to assign a conservative uncertainty to the calculated value, offering a way forward when CAD is to be used for a less well defined material. Finally, the candidate material demonstrated a propensity to absorb water, highlighting the need to monitor water absorption during on-going stability trials.


  • Production of certified reference materials for the sports doping control of the REV‐ERB agonist SR9009

    by Stephen R. Davies, Benjamin K.H. Chan, Michael Moawad, Taylor R. Garrett, Lance Brooker, Rima Chakrabarty

    Two human metabolites of the REV‐ERB agonist SR9009, identified by researchers with an interest in sports doping control, have been synthesized and assessed for purity. The synthesis employed was a modification of published procedures for the parent SR9009, careful attention to the purification of intermediates and the final product ensuring materials of the highest purity were available for certification. For each candidate material impurities of related structure were identified and quantified as a relative mass fraction using high performance liquid chromatography–ultraviolet (HPLC–UV) detection and proton nuclear magnetic resonance (1H NMR) spectroscopy. The quantification of water, occluded solvent, and inorganic residue was assessed using Karl Fischer, 1H NMR, and thermogravimetric analysis, thereby completing the assessment of all impurities typically characterized by the mass balance approach. Summation and subtraction from 1000 mg/g afforded the mass fraction of the main component, the associated uncertainty ensuring certified reference material status can be applied to the resulting pure substance calibration standards. The availability of these standards to the sports doping control community will facilitate delivery of metrological traceability to the SI unit for mass (kg) to routine testing results and aid method development for the detection and quantification of SR9009 abuse.


  • The development of an efficient mass balance approach for the purity assignment of organic calibration standards

    by Stephen R. Davies, Mahiuddin Alamgir, Benjamin K. H. Chan, Thao Dang, Kai Jones, Maya Krishnaswami, Yawen Luo, Peter S. R. Mitchell, Michael Moawad, Hilton Swan, et al.

    The purity determination of organic calibration standards using the traditional mass balance approach is described. Demonstrated examples highlight the potential for bias in each measurement and the need to implement an approach that provides a cross-check for each result, affording fit for purpose purity values in a timely and cost-effective manner. Chromatographic techniques such as gas chromatography with flame ionisation detection (GC-FID) and high-performance liquid chromatography with UV detection (HPLC-UV), combined with mass and NMR spectroscopy, provide a detailed impurity profile allowing an efficient conversion of chromatographic peak areas into relative mass fractions, generally avoiding the need to calibrate each impurity present. For samples analysed by GC-FID, a conservative measurement uncertainty budget is described, including a component to cover potential variations in the response of each unidentified impurity. An alternative approach is also detailed in which extensive purification eliminates the detector response factor issue, facilitating the certification of a super-pure calibration standard which can be used to quantify the main component in less-pure candidate materials. This latter approach is particularly useful when applying HPLC analysis with UV detection. Key to the success of this approach is the application of both qualitative and quantitative 1H NMR spectroscopy.


  • Report on the 33rd Meeting of ISO/REMCO

    by Hendrik Emons, Stephen R. Davies, John P. Hammond, Stéphane Sauvage


  • MEASUREMENT OF CHEMICAL REPAIR RATES IN INTACT CELLS FOR THIOLS OF DIFFERING NET CHARGE

    by N.E. Gillies, K.M. Prise, S. Davies, R.C. Fahey, B.D. Michael