Liat Appelbaum
Liat Appelbaum has a total of 34 co-authors. Here are the top co-authors by number of shared publications:
S. Nahum Goldberg
7 shared publicationsJacob Sosna
5 shared publicationsYizhak Nissenbaum
4 shared publications- Luigi Solbiati
Department of Biomedical Science, Humanitas University and Humanitas Clinical and Research Hospital IRCCS, Rozzano, Italy
2 shared publications Alexander Benshtein
1 shared publication- Amos Shapiro
Department of Urology, Hadassah University Medical Center, Jerusalem, Israel
1 shared publication
Latest Publications
- 23 November 2021
- Published by Springer Nature
- p. 49-58
Imaging Modalities in Venous-Thromboembolism: Ultrasound for Lower Extremity Deep Venous Thrombosis
- 23 November 2021
- Published by Springer Nature
- p. 49-58
Imaging Modalities in Venous-Thromboembolism: Ultrasound for Lower Extremity Deep Venous Thrombosis
- Open Access
- 1 January 2020
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 37 (1) , 366-372
US-guided laser treatment of parathyroid adenomas
Objective: To determine the clinical efficacy of laser ablation for the tredatment of primary hyperparathyroidism (pHPT). Materials and methods: Twelve patients with pHPT were treated with laser ablation. Energy was administered by means of 1.5 m optical fibers percutaneously placed into the target via 21 G needles. A laser ablation unit (EchoLaser X4, Esaote) applied 3 W power for 400–600 s/fiber/insertion to a total 3600–9000 Joules of energy. Patient serum parathyroid hormone (PTH) and calcium levels were checked at baseline and thereafter every 6 months. Patients were followed-up for 2 years with serologic and contrast-enhanced ultrasound. Therapeutic success was defined as normal PTH and calcium levels together with disappearance of nodule-related symptoms. Results: All procedures were performed in single session. Immediately following ablation, contrast enhanced ultrasound confirmed that all but one target had become avascular (technical success rate 11/12; 92%), remaining avascular at all follow-up ultrasound examinations, thereafter. The mean volume of parathyroid nodules decreased from 0.54 cc to 0.36 cc (72.0%). Serum PTH and calcium levels were significantly lower at 1, 12 and 24 m compared to baseline (p < 0.01). By 6 m, PTH and calcium returned to normal and were stable until 24 m in all successfully treated patients. All cases of hyperparathyroid-related symptoms resolved by 6 m (ostealgia [n = 5], repeated renal colic [n = 5], vomiting [n = 3]). Only one patient (8%) reported transient dysphonia as a minor complication. Conclusion: Laser ablation of enlarged, symptomatic parathyroid glands is safe and well-tolerated and can produce long-term, sustained reduction of serum PTH and calcium levels.
- 1 January 2020
- Published by Taylor & Francis in International Journal of Hyperthermia
- Vol. 37 (1) , 366-372
Open AccessUS-guided laser treatment of parathyroid adenomas
Objective: To determine the clinical efficacy of laser ablation for the tredatment of primary hyperparathyroidism (pHPT). Materials and methods: Twelve patients with pHPT were treated with laser ablation. Energy was administered by means of 1.5 m optical fibers percutaneously placed into the target via 21 G needles. A laser ablation unit (EchoLaser X4, Esaote) applied 3 W power for 400–600 s/fiber/insertion to a total 3600–9000 Joules of energy. Patient serum parathyroid hormone (PTH) and calcium levels were checked at baseline and thereafter every 6 months. Patients were followed-up for 2 years with serologic and contrast-enhanced ultrasound. Therapeutic success was defined as normal PTH and calcium levels together with disappearance of nodule-related symptoms. Results: All procedures were performed in single session. Immediately following ablation, contrast enhanced ultrasound confirmed that all but one target had become avascular (technical success rate 11/12; 92%), remaining avascular at all follow-up ultrasound examinations, thereafter. The mean volume of parathyroid nodules decreased from 0.54 cc to 0.36 cc (72.0%). Serum PTH and calcium levels were significantly lower at 1, 12 and 24 m compared to baseline (p < 0.01). By 6 m, PTH and calcium returned to normal and were stable until 24 m in all successfully treated patients. All cases of hyperparathyroid-related symptoms resolved by 6 m (ostealgia [n = 5], repeated renal colic [n = 5], vomiting [n = 3]). Only one patient (8%) reported transient dysphonia as a minor complication. Conclusion: Laser ablation of enlarged, symptomatic parathyroid glands is safe and well-tolerated and can produce long-term, sustained reduction of serum PTH and calcium levels.
- 1 December 2013
- Published by Elsevier in Techniques in Vascular and Interventional Radiology
- Vol. 16 (4) , 287-295
Image-Guided Fusion and Navigation: Applications in Tumor Ablation
- 1 December 2013
- Published by Elsevier in Techniques in Vascular and Interventional Radiology
- Vol. 16 (4) , 287-295
Image-Guided Fusion and Navigation: Applications in Tumor Ablation
- 1 June 2013
- Published by Elsevier in Seminars in Ultrasound, CT and MRI
- Vol. 34 (3) , 257-273
Scrotal Ultrasound in Adults
- 1 June 2013
- Published by Elsevier in Seminars in Ultrasound, CT and MRI
- Vol. 34 (3) , 257-273
Scrotal Ultrasound in Adults
- Open Access
- 8 May 2013
- Published by Springer Nature in BMC Urology
- Vol. 13 (1) , 23
The natural history of secondary muscle-invasive bladder cancer
Background: The management of patients with high-grade non muscle invasive bladder cancer (NMIBC) brings diagnostic and therapeutic challenges. In the current study, we sought to study the natural history of progression to "secondary" muscle-invasive bladder cancer (MIBC)-cancer that developed during follow up of patients presenting with non-muscle invasive bladder cancer (NMIBC). Methods: Between 1998 and 2008, 760 patients were treated for bladder cancer. Primary MIBC (>=T2) tumors (present upon presentation) were diagnosed in 114 patients. All patients with high-grade NMIBC were treated with intravesical BCG. Mean follow-up was 44 months. Results: Forty patients (6.1%) developed secondary MIBC after a mean period of 21 months from initial diagnosis of bladder cancer. The 2- and 5-year disease-specific survival rates were better for patients with secondary MIBC (90% and 56% compared to 69% and 42% for patients with primary disease, p=0.03). The Kaplan-Meier curves of the two groups were parallel but displaced by approximately 2 years. Conclusion: In the current series, MIBC progression occurred among initially presenting patients with NMIBC in 6.1%. In most patients, the initial diagnosis of NMIBC is correct and muscle invasion occurs after a mean period of about 2 years. This supports a non-radical approach in patients with high-grade T1, Ta or Tis. Meticulous follow-up with liberal biopsy of any suspicious lesion may provide early diagnosis of invasive disease.
- 8 May 2013
- Published by Springer Nature in BMC Urology
- Vol. 13 (1) , 23
Open AccessThe natural history of secondary muscle-invasive bladder cancer
Background: The management of patients with high-grade non muscle invasive bladder cancer (NMIBC) brings diagnostic and therapeutic challenges. In the current study, we sought to study the natural history of progression to "secondary" muscle-invasive bladder cancer (MIBC)-cancer that developed during follow up of patients presenting with non-muscle invasive bladder cancer (NMIBC). Methods: Between 1998 and 2008, 760 patients were treated for bladder cancer. Primary MIBC (>=T2) tumors (present upon presentation) were diagnosed in 114 patients. All patients with high-grade NMIBC were treated with intravesical BCG. Mean follow-up was 44 months. Results: Forty patients (6.1%) developed secondary MIBC after a mean period of 21 months from initial diagnosis of bladder cancer. The 2- and 5-year disease-specific survival rates were better for patients with secondary MIBC (90% and 56% compared to 69% and 42% for patients with primary disease, p=0.03). The Kaplan-Meier curves of the two groups were parallel but displaced by approximately 2 years. Conclusion: In the current series, MIBC progression occurred among initially presenting patients with NMIBC in 6.1%. In most patients, the initial diagnosis of NMIBC is correct and muscle invasion occurs after a mean period of about 2 years. This supports a non-radical approach in patients with high-grade T1, Ta or Tis. Meticulous follow-up with liberal biopsy of any suspicious lesion may provide early diagnosis of invasive disease.
- 1 February 2013
- Published by Elsevier in Academic Radiology
- Vol. 20 (2) , 209-217
Evaluation of an Electromagnetic Image-Fusion Navigation System for Biopsy of Small Lesions
- 1 February 2013
- Published by Elsevier in Academic Radiology
- Vol. 20 (2) , 209-217
Evaluation of an Electromagnetic Image-Fusion Navigation System for Biopsy of Small Lesions
- 1 January 2012
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 262 (1) , 117-125
US Findings after Irreversible Electroporation Ablation: Radiologic-Pathologic Correlation
To characterize ultrasonographic (US) findings after irreversible electroporation (IRE) to determine the utility of these findings in the accurate assessment of ablation margins. The institutional animal care and use committee approved the study. IRE ablation (n = 58) was performed in vivo in 16 pig livers by using two 18-gauge electroporation electrodes with 2-cm tip exposure, 1.5- or 2.0-cm interelectrode spacing, and an electroporation generator. Energy deposition was applied at 2250-3000 V (pulse length, 50-100 μsec; pulse repetition, 50-100). Ablations were performed under US guidance. Images were obtained during ablation and at defined intervals from 1 minute to 2 hours after the procedure. Zones of ablation were determined at gross and histopathologic examination of samples obtained from animals sacrificed 2-3 hours after IRE. Dimensions of the histologic necrosis zone and US findings were compared and subjected to statistical analysis, including a Student t test and multiple linear regression. Within 20-50 pulse repetitions of IRE energy, the ablation zone appeared as a hypoechoic area with well-demarcated margins. During the next 8-15 minutes, this zone decreased in size from 3.4 cm ± 0.5 to 2.5 cm ± 0.4 and became progressively more isoechoic. Subsequently, a peripheral hyperechoic rim measuring 2-7 mm (mean, 4 mm ± 1) surrounding the isoechoic zone developed 25-90 minutes (mean, 41 minutes ± 19) after IRE. The final length of the treatment zone, including the rim, increased to 3.3 cm ± 0.6. The final dimensions of the outer margin of this rim provided greatest accuracy (1.7 mm ± 0.2) and tightest correlation (r(2) = 0.89) with gross pathologic findings. Histologic examination demonstrated widened sinusoidal spaces that progressively filled with spatially distributed hemorrhagic infiltrate on a bed of hepatocytes with pyknotic nuclei throughout the treatment zone. US findings in the acute period after IRE are dynamic and evolve. The ablation zone can be best predicted by measuring the external hyperechoic rim that forms 90-120 minutes after ablation. This rim is possibly attributable to evolving hemorrhagic infiltration via widened sinusoids.
- 1 January 2012
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 262 (1) , 117-125
US Findings after Irreversible Electroporation Ablation: Radiologic-Pathologic Correlation
To characterize ultrasonographic (US) findings after irreversible electroporation (IRE) to determine the utility of these findings in the accurate assessment of ablation margins. The institutional animal care and use committee approved the study. IRE ablation (n = 58) was performed in vivo in 16 pig livers by using two 18-gauge electroporation electrodes with 2-cm tip exposure, 1.5- or 2.0-cm interelectrode spacing, and an electroporation generator. Energy deposition was applied at 2250-3000 V (pulse length, 50-100 μsec; pulse repetition, 50-100). Ablations were performed under US guidance. Images were obtained during ablation and at defined intervals from 1 minute to 2 hours after the procedure. Zones of ablation were determined at gross and histopathologic examination of samples obtained from animals sacrificed 2-3 hours after IRE. Dimensions of the histologic necrosis zone and US findings were compared and subjected to statistical analysis, including a Student t test and multiple linear regression. Within 20-50 pulse repetitions of IRE energy, the ablation zone appeared as a hypoechoic area with well-demarcated margins. During the next 8-15 minutes, this zone decreased in size from 3.4 cm ± 0.5 to 2.5 cm ± 0.4 and became progressively more isoechoic. Subsequently, a peripheral hyperechoic rim measuring 2-7 mm (mean, 4 mm ± 1) surrounding the isoechoic zone developed 25-90 minutes (mean, 41 minutes ± 19) after IRE. The final length of the treatment zone, including the rim, increased to 3.3 cm ± 0.6. The final dimensions of the outer margin of this rim provided greatest accuracy (1.7 mm ± 0.2) and tightest correlation (r(2) = 0.89) with gross pathologic findings. Histologic examination demonstrated widened sinusoidal spaces that progressively filled with spatially distributed hemorrhagic infiltrate on a bed of hepatocytes with pyknotic nuclei throughout the treatment zone. US findings in the acute period after IRE are dynamic and evolve. The ablation zone can be best predicted by measuring the external hyperechoic rim that forms 90-120 minutes after ablation. This rim is possibly attributable to evolving hemorrhagic infiltration via widened sinusoids.
- 1 May 2011
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 196 (5) , 1194-1200
Electromagnetic Navigation System for CT-Guided Biopsy of Small Lesions
OBJECTIVE. The purpose of this study was to evaluate an electromagnetic navigation system for CT-guided biopsy of small lesions.MATERIALS AND METHODS. Standardized CT anthropomorphic phantoms were biopsied by two attending radiologists. CT scans of the phantom and surface electromagnetic fiducial markers were imported into the memory of the 3D electromagnetic navigation system. Each radiologist assessed the accuracy of biopsy using electromagnetic navigation alone by targeting sets of nine lesions (size range, 8–14 mm; skin to target distance, 5.7–12.8 cm) under eight different conditions of detector field strength and orientation (n = 117). As a control, each radiologist also biopsied two sets of five targets using conventional CT-guided technique. Biopsy accuracy, number of needle passes, procedure time, and radiation dose were compared.RESULTS. Under optimal conditions (phantom perpendicular to the electromagnetic receiver at highest possible field strength), phantom accuracy to the center of the lesio...
- 1 May 2011
- Published by American Roentgen Ray Society in American Journal of Roentgenology
- Vol. 196 (5) , 1194-1200
Electromagnetic Navigation System for CT-Guided Biopsy of Small Lesions
OBJECTIVE. The purpose of this study was to evaluate an electromagnetic navigation system for CT-guided biopsy of small lesions.MATERIALS AND METHODS. Standardized CT anthropomorphic phantoms were biopsied by two attending radiologists. CT scans of the phantom and surface electromagnetic fiducial markers were imported into the memory of the 3D electromagnetic navigation system. Each radiologist assessed the accuracy of biopsy using electromagnetic navigation alone by targeting sets of nine lesions (size range, 8–14 mm; skin to target distance, 5.7–12.8 cm) under eight different conditions of detector field strength and orientation (n = 117). As a control, each radiologist also biopsied two sets of five targets using conventional CT-guided technique. Biopsy accuracy, number of needle passes, procedure time, and radiation dose were compared.RESULTS. Under optimal conditions (phantom perpendicular to the electromagnetic receiver at highest possible field strength), phantom accuracy to the center of the lesio...
- 1 February 2010
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 254 (2) , 430-440
Algorithm Optimization for Multitined Radiofrequency Ablation: Comparative Study in ex Vivo and in Vivo Bovine Liver
To prospectively optimize multistep algorithms for largest available multitined radiofrequency (RF) electrode system in ex vivo and in vivo tissues, to determine best energy parameters to achieve large predictable target sizes of coagulation, and to compare these algorithms with manufacturer's recommended algorithms.Institutional animal care and use committee approval was obtained for the in vivo portion of this study. Ablation (n = 473) was performed in ex vivo bovine liver; final tine extension was 5-7 cm. Variables in stepped-deployment RF algorithm were interrogated and included initial current ramping to 105 degrees C (1 degrees C/0.5-5.0 sec), the number of sequential tine extensions (2-7 cm), and duration of application (4-12 minutes) for final two to three tine extensions. Optimal parameters to achieve 5-7 cm of coagulation were compared with recommended algorithms. Optimal settings for 5- and 6-cm final tine extensions were confirmed in in vivo perfused bovine liver (n = 14). Multivariate analysis of variance and/or paired t tests were used.Mean RF ablation zones of 5.1 cm +/- 0.2 (standard deviation), 6.3 cm +/- 0.4, and 7 cm +/- 0.3 were achieved with 5-, 6-, and 7-cm final tine extensions in a mean of 19.5 min +/- 0.5, 27.9 min +/- 6, and 37.1 min +/- 2.3, respectively, at optimal settings. With these algorithms, size of ablation at 6- and 7-cm tine extension significantly increased from mean of 5.4 cm +/- 0.4 and 6.1 cm +/- 0.6 (manufacturer's algorithms) (P <.05, both comparisons); two recommended tine extensions were eliminated. In vivo confirmation produced mean diameter in specified time: 5.5 cm +/- 0.4 in 18.5 min +/- 0.5 (5-cm extensions) and 5.7 cm +/- 0.2 in 21.2 min +/- 0.6 (6-cm extensions).Large zones of coagulation of 5-7 cm can be created with optimized RF algorithms that help reduce number of tine extensions compared with manufacturer's recommendations. Such algorithms are likely to facilitate the utility of these devices for RF ablation of focal tumors in clinical practice.
- 1 February 2010
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 254 (2) , 430-440
Algorithm Optimization for Multitined Radiofrequency Ablation: Comparative Study in ex Vivo and in Vivo Bovine Liver
To prospectively optimize multistep algorithms for largest available multitined radiofrequency (RF) electrode system in ex vivo and in vivo tissues, to determine best energy parameters to achieve large predictable target sizes of coagulation, and to compare these algorithms with manufacturer's recommended algorithms.Institutional animal care and use committee approval was obtained for the in vivo portion of this study. Ablation (n = 473) was performed in ex vivo bovine liver; final tine extension was 5-7 cm. Variables in stepped-deployment RF algorithm were interrogated and included initial current ramping to 105 degrees C (1 degrees C/0.5-5.0 sec), the number of sequential tine extensions (2-7 cm), and duration of application (4-12 minutes) for final two to three tine extensions. Optimal parameters to achieve 5-7 cm of coagulation were compared with recommended algorithms. Optimal settings for 5- and 6-cm final tine extensions were confirmed in in vivo perfused bovine liver (n = 14). Multivariate analysis of variance and/or paired t tests were used.Mean RF ablation zones of 5.1 cm +/- 0.2 (standard deviation), 6.3 cm +/- 0.4, and 7 cm +/- 0.3 were achieved with 5-, 6-, and 7-cm final tine extensions in a mean of 19.5 min +/- 0.5, 27.9 min +/- 6, and 37.1 min +/- 2.3, respectively, at optimal settings. With these algorithms, size of ablation at 6- and 7-cm tine extension significantly increased from mean of 5.4 cm +/- 0.4 and 6.1 cm +/- 0.6 (manufacturer's algorithms) (P <.05, both comparisons); two recommended tine extensions were eliminated. In vivo confirmation produced mean diameter in specified time: 5.5 cm +/- 0.4 in 18.5 min +/- 0.5 (5-cm extensions) and 5.7 cm +/- 0.2 in 21.2 min +/- 0.6 (6-cm extensions).Large zones of coagulation of 5-7 cm can be created with optimized RF algorithms that help reduce number of tine extensions compared with manufacturer's recommendations. Such algorithms are likely to facilitate the utility of these devices for RF ablation of focal tumors in clinical practice.