KMKrishna Moorthy

Krishna Moorthy

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Krishna Moorthy has a total of 17 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Safety skills training for surgeons: A half-day educational programme improves knowledge, attitudes and awareness of patient safety

    by Sonal Arora, Nick Sevdalis, Maria Ahmed, Helen Wong, Ara Darzi, Krishna Moorthy, Charles Vincent

    • 1 January 2004
      • Vol. 98, 82-8

    Real-time synchronization of kinematic and video data for the comprehensive assessment of surgical skills.

    by Aristotelis Dosis, Fernando Bello, Krishna Moorthy, Yaron Munz, Duncan Gillies, Ara Darzi

    Surgical dexterity in operating theatres has traditionally been assessed subjectively. Electromagnetic (EM) motion tracking systems such as the Imperial College Surgical Assessment Device (ICSAD) have been shown to produce valid and accurate objective measures of surgical skill. To allow for video integration we have modified the data acquisition and built it within the ROVIMAS analysis software. We then used ActiveX 9.0 DirectShow video capturing and the system clock as a time stamp for the synchronized concurrent acquisition of kinematic data and video frames. Interactive video/motion data browsing was implemented to allow the user to concentrate on frames exhibiting certain kinematic properties that could result in operative errors. We exploited video-data synchronization to calculate the camera visual hull by identifying all 3D vertices using the ICSAD electromagnetic sensors. We also concentrated on high velocity peaks as a means of identifying potential erroneous movements to be confirmed by studying the corresponding video frames. The outcome of the study clearly shows that the kinematic data are precisely synchronized with the video frames and that the velocity peaks correspond to large and sudden excursions of the instrument tip. We validated the camera visual hull by both video and geometrical kinematic analysis and we observed that graphs containing fewer sudden velocity peaks are less likely to have erroneous movements. This work presented further developments to the well-established ICSAD dexterity analysis system. Synchronized real-time motion and video acquisition provides a comprehensive assessment solution by combining quantitative motion analysis tools and qualitative targeted video scoring.


  • Evaluation of Virtual Reality Bronchoscopy as a Learning and Assessment Tool

    by K. Moorthy, S. Smith, T. Brown, S. Bann, A. Darzi

    Background: Conventional training in bronchoscopy involves a trainee performing on a real patient under supervision. This method of training is not only expensive, but there is also potential for increased patient discomfort. Simulators permit the acquisition of necessary technical skills required for the procedure. Virtual reality (VR) has been an integral part of training in aviation, and the application of this technology in medical training needs to be evaluated. Objective: This study was conducted to evaluate the efficacy of a VR bronchoscopy simulator as a learning and assessment tool. Methods: The bronchoscopic simulator (HT Medical Systems, Maryland, USA) is a VR computer programme. The simulator has the ability to assess competence by a set of parameters, which formed the data for the study. Nine novices without previous bronchoscopic experience formed the study group (group 1). Nine experienced bronchoscopists having performed between 200 and 1,000 bronchoscopies formed the other group (group 2). We assessed the efficacy of the system as a learning tool by studying whether there was a significant difference between the first and subsequent sessions of the subjects from group 1 and by comparing the performance of the two groups. Statistical analysis was done using the Mann-Whitney U test and the Wilcoxon signed ranks test. Results: There was a significant difference in performance between the first attempt of group 1 and the performance of the experts in terms of percentage of segments visualised and number of wall collisions and the economy of performance. Among the subjects from group 1, there was a significant improvement in percentage of segments visualised by the third attempt (p = 0.04), in the economy of performance by the sixth attempt (0.008) and in the number of wall collisions by the sixth attempt (0.024). When each attempt of the novices was compared with the performance of group 2, the significance in the difference of the percentage of segments studied (p = 0.09) and the economy of performance disappeared by the third attempt (0.06), while the difference in the number of wall collisions disappeared by the fifth attempt (p = 0.06). Conclusions: This study has been able to establish the face, construct and content validity of the simulator and the potential for it to be an effective training tool.