Kate Alexander
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Kate Alexander has a total of 33 co-authors. Here are the top co-authors by number of shared publications:
- Marc-André D'ANjou
Ospedale Veterinario i Portoni Rossi, Bologna, 40069, Italy
3 shared publications - Eric Norman Carmel
Département de sciences cliniques, Faculté de Médecine Vétérinaire, Université de Montréal, Saint-Hyacinthe, QC, Canada
2 shared publications Guy Beauchamp
2 shared publications- Jerome R. E. del Castillo
Faculté de Médecine Vétérinaire Université de Montréal St‐Hyacinthe Canada
2 shared publications Laurent Blond
2 shared publicationsAllison L. Zwingenberger
Department of Surgical and Radiological Sciences; School of Veterinary Medicine; University of California; Davis CA 95616
1 shared publication
Latest Publications
- 13 November 2013
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 55 (3) , 251-262
VALIDATION OF A NOVEL TECHNIQUE FOR CREATING SIMULATED RADIOGRAPHS USING COMPUTED TOMOGRAPHY DATASETS
Understanding radiographic anatomy and the effects of varying patient and radiographic tube positioning on image quality can be a challenge for students. The purposes of this study were to develop and validate a novel technique for creating simulated radiographs using computed tomography (CT) datasets. A DICOM viewer (ORS Visual) plug-in was developed with the ability to move and deform cuboidal volumetric CT datasets, and to produce images simulating the effects of tube-patient-detector distance and angulation. Computed tomographic datasets were acquired from two dogs, one cat, and one horse. Simulated radiographs of different body parts (n = 9) were produced using different angles to mimic conventional projections, before actual digital radiographs were obtained using the same projections. These studies (n = 18) were then submitted to 10 board-certified radiologists who were asked to score visualization of anatomical landmarks, depiction of patient positioning, realism of distortion/magnification, and image quality. No significant differences between simulated and actual radiographs were found for anatomic structure visualization and patient positioning in the majority of body parts. For the assessment of radiographic realism, no significant differences were found between simulated and digital radiographs for canine pelvis, equine tarsus, and feline abdomen body parts. Overall, image quality and contrast resolution of simulated radiographs were considered satisfactory. Findings from the current study indicated that radiographs simulated using this new technique are comparable to actual digital radiographs. Further studies are needed to apply this technique in developing interactive tools for teaching radiographic anatomy and the effects of varying patient and tube positioning.
- 13 November 2013
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 55 (3) , 251-262
VALIDATION OF A NOVEL TECHNIQUE FOR CREATING SIMULATED RADIOGRAPHS USING COMPUTED TOMOGRAPHY DATASETS
Understanding radiographic anatomy and the effects of varying patient and radiographic tube positioning on image quality can be a challenge for students. The purposes of this study were to develop and validate a novel technique for creating simulated radiographs using computed tomography (CT) datasets. A DICOM viewer (ORS Visual) plug-in was developed with the ability to move and deform cuboidal volumetric CT datasets, and to produce images simulating the effects of tube-patient-detector distance and angulation. Computed tomographic datasets were acquired from two dogs, one cat, and one horse. Simulated radiographs of different body parts (n = 9) were produced using different angles to mimic conventional projections, before actual digital radiographs were obtained using the same projections. These studies (n = 18) were then submitted to 10 board-certified radiologists who were asked to score visualization of anatomical landmarks, depiction of patient positioning, realism of distortion/magnification, and image quality. No significant differences between simulated and actual radiographs were found for anatomic structure visualization and patient positioning in the majority of body parts. For the assessment of radiographic realism, no significant differences were found between simulated and digital radiographs for canine pelvis, equine tarsus, and feline abdomen body parts. Overall, image quality and contrast resolution of simulated radiographs were considered satisfactory. Findings from the current study indicated that radiographs simulated using this new technique are comparable to actual digital radiographs. Further studies are needed to apply this technique in developing interactive tools for teaching radiographic anatomy and the effects of varying patient and tube positioning.
- 14 March 2012
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 53 (3) , 258-265
A COMPARISON OF COMPUTED TOMOGRAPHY, COMPUTED RADIOGRAPHY, AND FILM‐SCREEN RADIOGRAPHY FOR THE DETECTION OF CANINE PULMONARY NODULES
Computed tomography (CT) has become more widely available and computed radiography (CR) has replaced film‐screen radiography for canine thoracic imaging in many veterinary practices. There are limited data comparing these modalities in a veterinary clinical setting to detect pulmonary nodules. We compared CT, CR, and film‐screen radiography for detecting the presence, number, and characteristics of pulmonary nodules in dogs. Observer performance for a variety of experience levels was also evaluated. Twenty‐one client‐owned dogs with a primary neoplastic process underwent CT and CR; nine also received film‐screen radiographs. Positive/negative classification by consensus agreed between the three modalities in 8/9 dogs and between CR and CT in the remaining 12. CT detected the greatest (P = 0.002) total number of nodules and no difference was seen between CR and films. The greatest number of nodules was seen in the right middle and both caudal regions, but only using CT (P < 0.0001). Significantly smaller nodules were detected with CT (P = 0.0007) and no difference in minimum size was detected between CR and films. Observer accuracy was high for all modalities; particularly for CT (90.5–100%) and for the senior radiologist (90.5–100%). CT was also characterized by the least interobserver variability. Although CT, CR, and film‐screen performed similarly in determining the presence or absence of pulmonary nodules, a greater number of smaller nodules was detected with CT, and CT was associated with greater diagnostic confidence and observer accuracy and agreement.
- 14 March 2012
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 53 (3) , 258-265
A COMPARISON OF COMPUTED TOMOGRAPHY, COMPUTED RADIOGRAPHY, AND FILM‐SCREEN RADIOGRAPHY FOR THE DETECTION OF CANINE PULMONARY NODULES
Computed tomography (CT) has become more widely available and computed radiography (CR) has replaced film‐screen radiography for canine thoracic imaging in many veterinary practices. There are limited data comparing these modalities in a veterinary clinical setting to detect pulmonary nodules. We compared CT, CR, and film‐screen radiography for detecting the presence, number, and characteristics of pulmonary nodules in dogs. Observer performance for a variety of experience levels was also evaluated. Twenty‐one client‐owned dogs with a primary neoplastic process underwent CT and CR; nine also received film‐screen radiographs. Positive/negative classification by consensus agreed between the three modalities in 8/9 dogs and between CR and CT in the remaining 12. CT detected the greatest (P = 0.002) total number of nodules and no difference was seen between CR and films. The greatest number of nodules was seen in the right middle and both caudal regions, but only using CT (P < 0.0001). Significantly smaller nodules were detected with CT (P = 0.0007) and no difference in minimum size was detected between CR and films. Observer accuracy was high for all modalities; particularly for CT (90.5–100%) and for the senior radiologist (90.5–100%). CT was also characterized by the least interobserver variability. Although CT, CR, and film‐screen performed similarly in determining the presence or absence of pulmonary nodules, a greater number of smaller nodules was detected with CT, and CT was associated with greater diagnostic confidence and observer accuracy and agreement.
- 7 March 2011
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 52 (4) , 451-456
COMPARISON OF SONOGRAPHIC FEATURES OF BENIGN AND NEOPLASTIC DEEP LYMPH NODES IN DOGS
The differentiation of benign vs. neoplastic lymph nodes impacts patient management. Specific sonographic features are typically considered when assessing lymph nodes in dogs. However, the usefulness of these criteria in distinguishing benign vs. malignant lymph nodes remains largely unknown, especially for deep lymph nodes. Our aim was to compare sonographic features in benign and neoplastic deep lymph nodes with the hope of identifying predictive criteria. Thirty‐one deep lymph nodes (16 mesenteric, 10 medial iliac, three hepatic, one sternal, and one cranial mediastinal) in 31 dogs were examined prospectively with B‐mode and Color flow Doppler. Lymph nodes were aspirated using ultrasound‐guidance and final diagnosis were established based on cytologic and/or histopathologic interpretation. Prevalence of each sonographic feature and combinations of two features was calculated for each group and compared using a χ2‐test or Student's t‐test for unequal variances. Ten lymph nodes were benign (hyperplastic and/or inflammatory) and 21 were neoplastic. All were hypoechoic, except for one neoplastic lymph node. Maximal short‐axis diameter (P=0.0006) and long‐axis diameter (P=0.01), and SA/LA ratio (P=0.008) were increased significantly for neoplastic (2.8, 5.5 cm, and 0.50, respectively) vs. benign (1.2, 3.8 cm, and 0.34, respectively) lymph nodes. The prevalence of other features was similar between groups. Doppler evaluation was possible in 77% of lymph nodes, but there was no significant difference between groups. When any two ultrasound features were combined, the only difference between benign and neoplastic lymph nodes was for the combination of contour regularity and appearance of the perinodal fat (P=0.03).
- 7 March 2011
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 52 (4) , 451-456
COMPARISON OF SONOGRAPHIC FEATURES OF BENIGN AND NEOPLASTIC DEEP LYMPH NODES IN DOGS
The differentiation of benign vs. neoplastic lymph nodes impacts patient management. Specific sonographic features are typically considered when assessing lymph nodes in dogs. However, the usefulness of these criteria in distinguishing benign vs. malignant lymph nodes remains largely unknown, especially for deep lymph nodes. Our aim was to compare sonographic features in benign and neoplastic deep lymph nodes with the hope of identifying predictive criteria. Thirty‐one deep lymph nodes (16 mesenteric, 10 medial iliac, three hepatic, one sternal, and one cranial mediastinal) in 31 dogs were examined prospectively with B‐mode and Color flow Doppler. Lymph nodes were aspirated using ultrasound‐guidance and final diagnosis were established based on cytologic and/or histopathologic interpretation. Prevalence of each sonographic feature and combinations of two features was calculated for each group and compared using a χ2‐test or Student's t‐test for unequal variances. Ten lymph nodes were benign (hyperplastic and/or inflammatory) and 21 were neoplastic. All were hypoechoic, except for one neoplastic lymph node. Maximal short‐axis diameter (P=0.0006) and long‐axis diameter (P=0.01), and SA/LA ratio (P=0.008) were increased significantly for neoplastic (2.8, 5.5 cm, and 0.50, respectively) vs. benign (1.2, 3.8 cm, and 0.34, respectively) lymph nodes. The prevalence of other features was similar between groups. Doppler evaluation was possible in 77% of lymph nodes, but there was no significant difference between groups. When any two ultrasound features were combined, the only difference between benign and neoplastic lymph nodes was for the combination of contour regularity and appearance of the perinodal fat (P=0.03).
- 1 May 2010
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 5 (3) , 133-139
Patlak plot analysis CT‐GFR for the determination of renal function: comparison of normal dogs with autologous kidney transplant dogs
Glomerular filtration rate (GFR) can be determined using Patlak plot analysis with single‐slice dynamic computed tomography (CT). Acute autologous graft failure has several causes, all of which induce a measurable decrease in glomerular filtration rate. This study demonstrated in an experimental model of canine autologous renal transplant that CT‐derived renal plasma clearance was significantly lower (p = 0.002) in dogs having undergone transplant (0.077 ± 0.058 ml min−1 ml renal tissue−1) compared with control dogs (0.396 ± 0.139 ml min−1 ml renal tissue−1). A significant negative curvilinear relationship was seen between serum creatinine and total renal plasma clearance (R2 = 0.84, p = 0.0001). Alterations in renal time attenuation curve shape in dogs having undergone transplant may have been related to increased renal vascular resistance related to tubular necrosis. CT‐GFR may be a useful experimental tool in the evaluation of renal dysfunction in transplant models. Copyright © 2010 John Wiley & Sons, Ltd.
- 1 May 2010
- Published by Wiley in Contrast Media & Molecular Imaging
- Vol. 5 (3) , 133-139
Patlak plot analysis CT‐GFR for the determination of renal function: comparison of normal dogs with autologous kidney transplant dogs
Glomerular filtration rate (GFR) can be determined using Patlak plot analysis with single‐slice dynamic computed tomography (CT). Acute autologous graft failure has several causes, all of which induce a measurable decrease in glomerular filtration rate. This study demonstrated in an experimental model of canine autologous renal transplant that CT‐derived renal plasma clearance was significantly lower (p = 0.002) in dogs having undergone transplant (0.077 ± 0.058 ml min−1 ml renal tissue−1) compared with control dogs (0.396 ± 0.139 ml min−1 ml renal tissue−1). A significant negative curvilinear relationship was seen between serum creatinine and total renal plasma clearance (R2 = 0.84, p = 0.0001). Alterations in renal time attenuation curve shape in dogs having undergone transplant may have been related to increased renal vascular resistance related to tubular necrosis. CT‐GFR may be a useful experimental tool in the evaluation of renal dysfunction in transplant models. Copyright © 2010 John Wiley & Sons, Ltd.
- 16 February 2010
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 51 (4) , 421-427
CLINICAL APPLICATION OF PATLAK PLOT CT-GFR IN ANIMALS WITH UPPER URINARY TRACT DISEASE
Glomerular filtration rate (GFR), an important parameter of renal function, is difficult to assess clinically. Serum creatinine and blood urea nitrogen measurements lack sensitivity, whereas radionuclide determination of GFR is not always available and requires postinjection patient isolation. GFR can be determined using computed tomography (CT), most commonly via Patlak plot analysis. Four adult cats, two adult dogs, and a foal underwent abdominal CT under general anesthesia for various diseases of the upper urinary tract. CT‐GFR was measured with a single‐slice dynamic acquisition and Patlak plot analysis. In five animals, the total CT‐GFR appeared to be below normal, corresponding with mild (two animals) and moderate (two animals) increases of serum creatinine in four. In the two animals with normal or increased CT‐GFR, serum creatinine was within the reference values. A significant negative logarithmic relationship was found between CT‐GFR and serum creatinine values (P=0.008; r2=0.75). No complications occurred during or following CT‐GFR. CT examination provided clinically relevant information in 3/5 patients with possible ureteral obstruction and in 3/3 patients with suspected ureteral calculi. Single‐slice dynamic CT‐GFR was practical and provided clinically useful information in this small series of patients undergoing CT of the upper urinary tract. There was a significant relationship between CT‐GFR and serum creatinine values, which supports the clinical potential of CT‐GFR and justifies further investigation of this technique.
- 16 February 2010
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 51 (4) , 421-427
CLINICAL APPLICATION OF PATLAK PLOT CT-GFR IN ANIMALS WITH UPPER URINARY TRACT DISEASE
Glomerular filtration rate (GFR), an important parameter of renal function, is difficult to assess clinically. Serum creatinine and blood urea nitrogen measurements lack sensitivity, whereas radionuclide determination of GFR is not always available and requires postinjection patient isolation. GFR can be determined using computed tomography (CT), most commonly via Patlak plot analysis. Four adult cats, two adult dogs, and a foal underwent abdominal CT under general anesthesia for various diseases of the upper urinary tract. CT‐GFR was measured with a single‐slice dynamic acquisition and Patlak plot analysis. In five animals, the total CT‐GFR appeared to be below normal, corresponding with mild (two animals) and moderate (two animals) increases of serum creatinine in four. In the two animals with normal or increased CT‐GFR, serum creatinine was within the reference values. A significant negative logarithmic relationship was found between CT‐GFR and serum creatinine values (P=0.008; r2=0.75). No complications occurred during or following CT‐GFR. CT examination provided clinically relevant information in 3/5 patients with possible ureteral obstruction and in 3/3 patients with suspected ureteral calculi. Single‐slice dynamic CT‐GFR was practical and provided clinically useful information in this small series of patients undergoing CT of the upper urinary tract. There was a significant relationship between CT‐GFR and serum creatinine values, which supports the clinical potential of CT‐GFR and justifies further investigation of this technique.
- 1 October 2005
- Vol. 69 (4) , 272-7
Binding of ciprofloxacin labelled with technetium Tc 99m versus 99mTc-pertechnetate to a live and killed equine isolate of Escherichia coil.
This paper describes a simple methodology for evaluating the bacterial binding of ciprofloxacin labelled with technetium Tc 99m. Using this methodology, the binding of 99mTc-ciprofloxacin by live Escherichia coli was compared with the binding of 99mTc-ciprofloxacin by killed E. coli and the binding of 99mTc-pertechnetate (99mTcO4-) by live E. coli. The antimicrobial effect of 99mTc-ciprofloxacin on E. coli was evaluated. Four groups were defined: live E. coli with 99mTc-ciprofloxacin, live E. coli with 99mTcO4 , killed E. coli with 99mTc-ciprofloxacin, and killed E. coli with 99mTcO4-. After 0, 2, and 4 h of incubation of 1 x 10(8) colony-forming units of E. coli suspended in 5 mL of sterile distilled water with 1.85 MBq of 99mTc-ciprofloxacin or 99mTcO4, 1 mL from each sample was centrifuged. The radioactivity of the bacterial pellet and that of the supernatant were measured separately, and the percentage of sample radioactivity attributable to bacterial binding was calculated. Of the 99mTc-ciprofloxacin, 3.6% to 5.9% was bound to live or killed E. coli; only 0.1% to 0.2% of the 99mTcO4- was bound to live E. coli (P < 0.0001). No significant difference in 99mTc-ciprofloxacin binding was found between live and killed E. coli (P = 0.887). An antimicrobial effect on E. coli was seen with 99mTc-ciprofloxacin: colony counts were reduced after 4 h. The small amount of 99mTc-ciprofloxacin binding and the lack of difference in binding between live and killed E. coli may limit the utility of this methodology in evaluating the presence of E. coli infection.
- 1 October 2005
- Vol. 69 (4) , 272-7
Binding of ciprofloxacin labelled with technetium Tc 99m versus 99mTc-pertechnetate to a live and killed equine isolate of Escherichia coil.
This paper describes a simple methodology for evaluating the bacterial binding of ciprofloxacin labelled with technetium Tc 99m. Using this methodology, the binding of 99mTc-ciprofloxacin by live Escherichia coli was compared with the binding of 99mTc-ciprofloxacin by killed E. coli and the binding of 99mTc-pertechnetate (99mTcO4-) by live E. coli. The antimicrobial effect of 99mTc-ciprofloxacin on E. coli was evaluated. Four groups were defined: live E. coli with 99mTc-ciprofloxacin, live E. coli with 99mTcO4 , killed E. coli with 99mTc-ciprofloxacin, and killed E. coli with 99mTcO4-. After 0, 2, and 4 h of incubation of 1 x 10(8) colony-forming units of E. coli suspended in 5 mL of sterile distilled water with 1.85 MBq of 99mTc-ciprofloxacin or 99mTcO4, 1 mL from each sample was centrifuged. The radioactivity of the bacterial pellet and that of the supernatant were measured separately, and the percentage of sample radioactivity attributable to bacterial binding was calculated. Of the 99mTc-ciprofloxacin, 3.6% to 5.9% was bound to live or killed E. coli; only 0.1% to 0.2% of the 99mTcO4- was bound to live E. coli (P < 0.0001). No significant difference in 99mTc-ciprofloxacin binding was found between live and killed E. coli (P = 0.887). An antimicrobial effect on E. coli was seen with 99mTc-ciprofloxacin: colony counts were reduced after 4 h. The small amount of 99mTc-ciprofloxacin binding and the lack of difference in binding between live and killed E. coli may limit the utility of this methodology in evaluating the presence of E. coli infection.
- 1 July 2005
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 46 (4) , 340-347
99MTC‐CIPROFLOXACIN IN IMAGING OF CLINICAL INFECTIONS IN CAMELIDS AND A GOAT
(99M)Tc-ciprofloxacin was used to image five adult camelids and a juvenile goat with clinical and/or radiographic signs of infection. (99m)Tc-ciprofloxacin (range 10-33 MBq/kg) was injected intravenously and a series of 2-min static images were acquired at 1- and 4-h postinjection. At 24-h postinjection, 5-min static images were acquired. Only the skull or abdomen was imaged in the adults; the whole body was imaged in the goat. The quality of the 1-, 4-, and 24-h studies was evaluated subjectively. Normal and abnormal areas of (99m)Tc-ciprofloxacin uptake were recorded and subjectively graded as mild, moderate or intense. Image quality was best 4-h postinjection. Twenty-four-hour images were poor because of insufficient radioactivity. (99m)Tc-ciprofloxacin imaging resulted in true positive or true negative scans in four of six animals. Two false-negative studies occurred. Intense (99m)Tc-cirofloxacin activity was seen in the lungs and urinary bladder, moderate/intense activity in the kidneys, and mild activity in the physes/epiphyses, liver and intermittently in the gastrointestinal tract. The normal distribution of (99m)Tc-ciprofloxacin in camelids/small ruminants differed from people. Further studies to determine the sensitivity and specificity of infection detection using (99m)Tc-ciprofloxacin in animals are warranted.
- 1 July 2005
- Published by Wiley in Veterinary Radiology & Ultrasound
- Vol. 46 (4) , 340-347
99MTC‐CIPROFLOXACIN IN IMAGING OF CLINICAL INFECTIONS IN CAMELIDS AND A GOAT
(99M)Tc-ciprofloxacin was used to image five adult camelids and a juvenile goat with clinical and/or radiographic signs of infection. (99m)Tc-ciprofloxacin (range 10-33 MBq/kg) was injected intravenously and a series of 2-min static images were acquired at 1- and 4-h postinjection. At 24-h postinjection, 5-min static images were acquired. Only the skull or abdomen was imaged in the adults; the whole body was imaged in the goat. The quality of the 1-, 4-, and 24-h studies was evaluated subjectively. Normal and abnormal areas of (99m)Tc-ciprofloxacin uptake were recorded and subjectively graded as mild, moderate or intense. Image quality was best 4-h postinjection. Twenty-four-hour images were poor because of insufficient radioactivity. (99m)Tc-ciprofloxacin imaging resulted in true positive or true negative scans in four of six animals. Two false-negative studies occurred. Intense (99m)Tc-cirofloxacin activity was seen in the lungs and urinary bladder, moderate/intense activity in the kidneys, and mild activity in the physes/epiphyses, liver and intermittently in the gastrointestinal tract. The normal distribution of (99m)Tc-ciprofloxacin in camelids/small ruminants differed from people. Further studies to determine the sensitivity and specificity of infection detection using (99m)Tc-ciprofloxacin in animals are warranted.