ECEric Norman Carmel

Eric Norman Carmel

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Eric Norman Carmel has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Use of cystoscopic-guided laser ablation for treatment of unilateral ureterovesicular stenosis and secondary orthotopic ureterocele in a female dog

    by Mylene Auger, Anne-Sophie Bua, Éric Norman Carmel, Marilyn Dunn

    CASE DESCRIPTION A 4-year-old spayed female Beagle was evaluated because of a 2-month history of intermittent pollakiuria, stranguria, dysuria, and abdominal pain. A diagnosis of bacterial cystitis was initially made, but clinical signs persisted despite appropriate antimicrobial treatment, so the dog was referred for further evaluation and treatment. CLINICAL FINDINGS Abdominal ultrasonography revealed a large, thin-walled, cystic structure in the urinary bladder at the level of the expected right ureterovesicular junction that communicated with the uniformly dilated right ureter. Severe right-sided pyelectasia was also detected. A presumptive diagnosis was made of a right-sided orthotopic ureterocele with secondary hydroureter and pyelectasia. TREATMENT AND OUTCOME Cystoscopy revealed a large cystic structure in the region of the right ureterovesicular junction without obvious communication between the ureter and urinary bladder. Portable C-arm fluoroscopy was used to confirm the presence of an intramural orthotopic tract and to measure the diameter of the ureter and renal pelvis via retrograde contrast ureteropyelography. Complete laser ablation of the ureterocele was performed by incising it circumferentially near its base. Clinical signs resolved immediately following the procedure. Six weeks later, the dog remained free of clinical signs and abdominal ultrasonography revealed resolution of hydroureter with persistence of mild right-sided pyelectasia. CLINICAL RELEVANCE Cystoscopic-guided laser ablation of an orthotopic ureterocele secondary to ureterovesicular stenosis was a safe and effective minimally invasive treatment for the dog of this report, resulting in immediate and continued improvement of clinical signs and ultrasonographic changes. Laser ablation should be considered as an alternative to surgery for the treatment of orthotopic ureteroceles in dogs.


  • Distribution of bupivacaine hydrochloride after sciatic and femoral nerve blocks in cats: A magnetic resonance imaging study

    by Marina C Evangelista, Julie de Lassalle, Christine Chevrier, Eric N. Carmel, Denise T Fantoni, Paulo V M Steagall


  • Association between ultrasonographic appearance of splenic parenchyma and cytology in cats

    by Mileva Bertal, Eric Norman Carmel, Alessia Diana, Loic Desquilbet, Swan Specchi, Pascaline Pey

    Objectives: The purpose of this study was to determine whether the presence of a splenic mass or a diffusely moth-eaten parenchyma on ultrasonographic scans could represent potential criteria of malignancy in the feline spleen. Methods: Feline patients with ultrasonographic images and cytological analysis of the spleen obtained by fine-needle aspiration were retrospectively included in a multicentre study. Results: One hundred and ninety-five cats met our inclusion criteria. There was a lack of agreement between the moth-eaten ultrasonographic appearance of the spleen and the presence of a malignant neoplasia on cytological analysis. The sensitivity and specificity of a moth-eaten parenchyma for predicting malignant neoplastic disease were 13.2% and 84.8%, respectively. The sensitivity and specificity of a splenic mass >1 cm for predicting malignant neoplastic disease were 21.0% and 94.7%, respectively. A marbled appearance of the splenic parenchyma was significantly more frequent among patients examined with a high-frequency transducer (11–18 MHz) than among those examined with a low-frequency transducer (6.6–10 MHz) (27.6% vs 11.1%, respectively; P = 0.004). Similarly, although not statistically significant, a moth-eaten parenchyma was more frequent in the high-frequency transducer group than in the low-frequency group (17.1% vs 8.9%, respectively; P = 0.09). Conclusions and relevance: Based on our findings, a moth-eaten ultrasonographic appearance of the spleen in cats does not necessarily reflect a lymphoma or another malignant neoplastic process on cytological analysis. The presence of a splenic mass >1 cm on ultrasound is suggestive of malignancy in cats. Finally, the transducer frequency must be taken into account when assessing the splenic parenchyma, as a high-frequency transducer seems to improve the detection of a marbled or moth-eaten parenchyma.


  • Cholecystopexy and Pericardial Pseudocyst Removal in a Dog with a Congenital Peritoneopericardial Diaphragmatic Hernia

    by Quentin Cabon, Eric Norman Carmel, Julien Cabassu

    A 4 mo old spayed female golden retriever was presented with a peritoneopericardial diaphragmatic hernia (PPDH) that was diagnosed during neutering. Echocardiography revealed a fluid-filled structure and parts of the liver in the pericardial cavity. Computed tomography confirmed the existence of the PPDH and the herniation of the right medial liver lobe and the gallbladder. Cystic masses were observed in the pericardial and the peritoneal cavities, possibly communicating through the PPDH. A median laparotomy revealed a single lobulated cystic lesion extending into both the pericardial and peritoneal cavities through the PPDH. Because of the nonviable aspect of some parts of the liver parenchyma, the gallbladder was dissected from the fossa, and the central division of the liver was resected. A cholecystopexy was performed on the diaphragm to limit gallbladder mobility. The PPDH was closed in the standard fashion. Histopathology of the cystic structure was compatible with a pericardial pseudocyst. Two months postoperatively, the dog was healthy, and the results of blood biochemistry and abdominal ultrasonography were normal. A pericardial pseudocyst can be associated with a PPDH in young dogs. Moreover, cholecystopexy appears to be a safe and effective method of limiting gallbladder mobility after resection of the central hepatic division.


    • 1 June 2014
      • Vol. 55  (6) , 544-6

    Congenital urethral stenosis in a male miniature piglet.

    by Bénédicte Pouleur-Larrat, Edouard Maccolini, Eric Norman Carmel, Pierre Hélie

    A 2-month-old male miniature pig showed progressive abdominal pain, pollakiuria, and stranguria that progressed to complete urinary obstruction. Postmortem examination revealed idiopathic urethral stenosis at the level of the recess, of probable congenital origin. Urinary tract malformations should be included in the differential diagnosis of miniature piglets with urinary disorders.

  • COMPUTED TOMOGRAPHIC CHARACTERISTICS OF COLLATERAL VENOUS PATHWAYS IN DOGS WITH CAUDAL VENA CAVA OBSTRUCTION

    by Swan Specchi, Marc‐André D’aNjou, Eric Norman Carmel, Giovanna Bertolini

    Collateral venous pathways develop in dogs with obstruction or increased blood flow resistance at any level of the caudal vena cava in order to maintain venous drainage to the right atrium. The purpose of this retrospective study was to describe the sites, causes of obstruction, and configurations of venous collateral pathways for a group of dogs with caudal vena cava obstruction. Computed tomography databases from two veterinary hospitals were searched for dogs with a diagnosis of caudal vena cava obstruction and multidetector row computed tomographic angiographic (CTA) scans that included the entire caudal vena cava. Images for each included dog were retrieved and collateral venous pathways were characterized using image postprocessing and a classification system previously reported for humans. A total of nine dogs met inclusion criteria and four major collateral venous pathways were identified: deep (n= 2), portal (n= 2), intermediate (n= 7), and superficial (n= 5). More than one collateral venous pathway was present in 5 dogs. An alternative pathway consisting of renal subcapsular collateral veins, arising mainly from the caudal pole of both kidneys, was found in three dogs. In conclusion, findings indicated that collateral venous pathway patterns similar to those described in humans are also present in dogs with caudal vena cava obstruction. These collateral pathways need to be distinguished from other vascular anomalies in dogs. Postprocessing of multidetector‐row CTA images allowed delineation of the course of these complicated venous pathways and may be a helpful adjunct for treatment planning in future cases.


  • VALIDATION OF A NOVEL TECHNIQUE FOR CREATING SIMULATED RADIOGRAPHS USING COMPUTED TOMOGRAPHY DATASETS

    by Patricia Mendoza, Marc-André D'Anjou, Éric N. Carmel, Éric Fournier, Wilfried Mai, Kate Alexander, Matthew D. Winter, Allison L. Zwingenberger, Donald E. Thrall, Christine Theoret

    Understanding radiographic anatomy and the effects of varying patient and radiographic tube positioning on image quality can be a challenge for students. The purposes of this study were to develop and validate a novel technique for creating simulated radiographs using computed tomography (CT) datasets. A DICOM viewer (ORS Visual) plug-in was developed with the ability to move and deform cuboidal volumetric CT datasets, and to produce images simulating the effects of tube-patient-detector distance and angulation. Computed tomographic datasets were acquired from two dogs, one cat, and one horse. Simulated radiographs of different body parts (n = 9) were produced using different angles to mimic conventional projections, before actual digital radiographs were obtained using the same projections. These studies (n = 18) were then submitted to 10 board-certified radiologists who were asked to score visualization of anatomical landmarks, depiction of patient positioning, realism of distortion/magnification, and image quality. No significant differences between simulated and actual radiographs were found for anatomic structure visualization and patient positioning in the majority of body parts. For the assessment of radiographic realism, no significant differences were found between simulated and digital radiographs for canine pelvis, equine tarsus, and feline abdomen body parts. Overall, image quality and contrast resolution of simulated radiographs were considered satisfactory. Findings from the current study indicated that radiographs simulated using this new technique are comparable to actual digital radiographs. Further studies are needed to apply this technique in developing interactive tools for teaching radiographic anatomy and the effects of varying patient and tube positioning.

  • Interobserver agreement and diagnostic accuracy of brain magnetic resonance imaging in dogs

    by Mylène-Kim Leclerc, Marc-André D'ANjou, Laurent Blond, Éric Norman Carmel, Ruth Dennis, Susan L. Kraft, Andrea R. Matthews, Joane M. Parent

    Objective—To evaluate interobserver agreement and diagnostic accuracy of brain MRI in dogs. Design—Evaluation study. Animals—44 dogs. Procedures—5 board-certified veterinary radiologists with variable MRI experience interpreted transverse T2-weighted (T2w), T2w fluid-attenuated inversion recovery (FLAIR), and T1-weighted-FLAIR; transverse, sagittal, and dorsal T2w; and T1-weighted-FLAIR postcontrast brain sequences (1.5 T). Several imaging parameters were scored, including the following: lesion (present or absent), lesion characteristics (axial localization, mass effect, edema, hemorrhage, and cavitation), contrast enhancement characteristics, and most likely diagnosis (normal, neoplastic, inflammatory, vascular, metabolic or toxic, or other). Magnetic resonance imaging diagnoses were determined initially without patient information and then repeated, providing history and signalment. For all cases and readers, MRI diagnoses were compared with final diagnoses established with results from histologic examination (when available) or with other pertinent clinical data (CSF analysis, clinical response to treatment, or MRI follow-up). Magnetic resonance scores were compared between examiners with κ statistics. Results—Reading agreement was substantial to almost perfect (0.64 < κ < 0.86) when identifying a brain lesion on MRI; fair to moderate (0.14 < κ < 0.60) when interpreting hemorrhage, edema, and pattern of contrast enhancement; fair to substantial (0.22 < κ < 0.74) for dural tail sign and categorization of margins of enhancement; and moderate to substantial (0.40 < κ < 0.78) for axial localization, presence of mass effect, cavitation, intensity, and distribution of enhancement. Interobserver agreement was moderate to substantial for categories of diagnosis (0.56 < κ < 0.69), and agreement with the final diagnosis was substantial regardless of whether patient information was (0.65 < κ < 0.76) or was not (0.65 < κ < 0.68) provided. Conclusions and Clinical Relevance—The present study found that whereas some MRI features such as edema and hemorrhage were interpreted less consistently, radiologists were reasonably constant and accurate when providing diagnoses.


  • EFFECT OF ACQUISITION TIME AND CHEMICAL FAT SUPPRESSION ON MENINGEAL ENHANCEMENT ON MR IMAGING IN DOGS

    by Marc‐André D'ANjou, Éric Norman Carmel, Laurent Blond, Guy Beauchamp, Joane Parent

    Our purpose was to characterize meningeal gadolinium enhancement on magnetic resonance (MR) imaging in dogs with inflammatory and neoplastic diseases, and to assess interobserver variability and the impact of delayed acquisition and chemical fat saturation on its conspicuity. Transverse T1‐weighted FLAIR images were acquired prior to, and immediately following gadolinium injection (T0), and at 5 (T5) and 15–20 min delay (TD), with and without fat suppression, in 155 consecutive dogs imaged for suspected brain disease. The agreement on meningeal enhancement was globally substantial (κ = 0.61) and the likelihood of obtaining a definite diagnosis was significantly increased with the use of fat suppression (P ≤ 0.004). Meningeal enhancement was judged definitively present by consensus in 46 of 155 (30%) dogs. Of these, meningeal enhancement was characterized qualitatively and quantitatively in 30 dogs with a clinical diagnosis (18 inflammatory, 11 neoplastic, 1 infarct), and image sequences were compared. Meningeal enhancement was more often diffuse and leptomeningeal in animals with inflammation versus neoplasia (50% vs. 42%, and 69% vs. 48%, respectively), but significant associations were not found. Meningeal thickness and contrast ratio were higher with neoplasia (P ≤ 0.02), but results did not vary significantly between series for either group. Yet, images with fat suppression were most useful 50% of the time for definite diagnosis and/or characterization of meningeal enhancement. While delayed image acquisition following gadolinium injection does not improve characterization of meningeal enhancement in dogs, fat suppression is beneficial qualitatively.


  • VALUE OF FAT SUPPRESSION IN GADOLINIUM‐ENHANCED MAGNETIC RESONANCE NEUROIMAGING

    by Marc‐André D'ANjou, Éric Norman Carmel, Amy S. Tidwell

    T1‐weighted, gadolinium‐enhanced magnetic resonance imaging is frequently used to investigate neurologic disease in small animals; however, the abundance of hyperintense adipose tissue adjacent to neural structures, particularly the cranial nerves and spinal cord, can decrease the conspicuity of contrast‐enhanced tissues on T1‐weighted images. For this reason, chemical fat saturation techniques are used to suppress the signal of adipose tissues, enabling improved depiction of gadolinium‐enhanced structures and detection of lesions affecting the nervous system.