Carsten Warmuth
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Carsten Warmuth has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
Bernd Hamm
1 shared publicationHerbert Pilgrimm
1 shared publicationJörg Schnorr
1 shared publicationMatthias Taupitz
1 shared publicationNicola Kaufels
1 shared publicationSusanne Wagner
1 shared publication
Latest Publications
- 1 August 2007
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 42 (8) , 550-557
Whole-Heart Coronary Magnetic Resonance Angiography
To test the feasibility and performance of a 4D magnetic resonance coronary angiography sequence compared with conventional inversion recovery (IR) prepared gradient echo imaging. A 4D sequence with 100 milliseconds temporal resolution was implemented on a 1.5 T system. Five minipigs were examined after administration of very small superparamagnetic iron oxide particles. Coronary angiographies with an isotropic resolution of 0.82 mm were performed in the pigs using 4D and IR sequences. The 4D sequence allowed visualization of the coronary arteries, the effect of their movement and that of the entire heart without prolonging scan time. The contrast-to-noise ratio of the IR images was on average 38% higher than that of the corresponding 4D phase. 4D magnetic resonance imaging is superior in that no trigger delay time needs to be determined and an additional whole-heart cine study can be obtained.
- 1 August 2007
- Published by Wolters Kluwer Health in Investigative Radiology
- Vol. 42 (8) , 550-557
Whole-Heart Coronary Magnetic Resonance Angiography
To test the feasibility and performance of a 4D magnetic resonance coronary angiography sequence compared with conventional inversion recovery (IR) prepared gradient echo imaging. A 4D sequence with 100 milliseconds temporal resolution was implemented on a 1.5 T system. Five minipigs were examined after administration of very small superparamagnetic iron oxide particles. Coronary angiographies with an isotropic resolution of 0.82 mm were performed in the pigs using 4D and IR sequences. The 4D sequence allowed visualization of the coronary arteries, the effect of their movement and that of the entire heart without prolonging scan time. The contrast-to-noise ratio of the IR images was on average 38% higher than that of the corresponding 4D phase. 4D magnetic resonance imaging is superior in that no trigger delay time needs to be determined and an additional whole-heart cine study can be obtained.