Bradley B. Hill
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Bradley B. Hill has a total of 24 co-authors. Here are the top co-authors by number of shared publications:
Christopher K. Zarins
Stanford University Medical Center, Stanford, California, USA
6 shared publicationsThomas J. Fogarty
Stanford University Medical Center, Stanford, California, USA
5 shared publicationsFrank R. Arko
Stanford University Medical Center, Stanford, California, USA
3 shared publicationsCornelius Olcott
2 shared publicationsE. John Harris
2 shared publicationsW. Anthony Lee
2 shared publications
Latest Publications
- 1 November 2005
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 42 (5) , 945-950
Keyhole technique for autologous brachiobasilic transposition arteriovenous fistula
- 1 November 2005
- Published by Elsevier in Journal of Vascular Surgery
- Vol. 42 (5) , 945-950
Keyhole technique for autologous brachiobasilic transposition arteriovenous fistula
- 1 June 2005
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 12 (3) , 394-400
“Over-the-Wire” Inversion Saphenectomy:A Simple, Minimally Invasive Vein Harvesting Technique for Arterial Bypass
Purpose: To examine the feasibility and clinical outcome of a novel, minimally invasive technique for harvesting the great saphenous vein (GSV) for use in peripheral arterial bypass surgery. Methods: Between May 2001 through March 2003, 27 patients (15 men; mean age 71±10 years) underwent extremity bypass procedures for limb salvage (88%) or disabling claudication (12%) using the inversion technique to harvest the GSV. The veins were turned “inside out” using a unique catheter and guidewire system. With the endothelial surface exposed, valve leaflets were excised, and adherent thrombus was washed away. Veins were inverted again to turn the endothelial surface back inside the lumen for use as a bypass conduit. Results: Inversion vein harvesting and arterial bypass were completed in 24 (89%) of 27 patients; 2 patients were treated with synthetic grafts because of small GSVs. Another patient was found after vein harvesting to have inadequate arterial outflow despite a good quality conduit. The average vein length was 45±10 cm; a mean 4±1 incisions were made, including those for arterial exposure. Incisions made to divide vein tributaries averaged 2 cm in length. Duration of vein harvesting was 25 minutes (range 5–80). Wound complications were minor (2 hematomas, 2 cases of erythema, 2 seromas). Of 6 grafts that occluded after 30 days, 5 involved small-diameter vein grafts (< 3.5 mm). At a mean 12 months, primary and assisted primary graft patency rates were 88% (14/16) and 94% (15/16), respectively, for grafts with minimum diameters ≥4 mm versus 38% (3/8) primary patency for veins < 4 mm (n=8, p < 0.001). The limb salvage rate was 92% (22/24). Conclusions: Over-the-wire inversion saphenectomy is a simple and reliable minimally invasive technique for arterial bypass. Incisions are small and cosmetically superior to those of the traditional long incision method. One-year follow-up suggests that grafts harvested by inversion technique have excellent durability when the minimum vein diameter is ≥4 mm, as determined by preoperative vein mapping.
- 1 June 2005
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 12 (3) , 394-400
“Over-the-Wire” Inversion Saphenectomy:A Simple, Minimally Invasive Vein Harvesting Technique for Arterial Bypass
Purpose: To examine the feasibility and clinical outcome of a novel, minimally invasive technique for harvesting the great saphenous vein (GSV) for use in peripheral arterial bypass surgery. Methods: Between May 2001 through March 2003, 27 patients (15 men; mean age 71±10 years) underwent extremity bypass procedures for limb salvage (88%) or disabling claudication (12%) using the inversion technique to harvest the GSV. The veins were turned “inside out” using a unique catheter and guidewire system. With the endothelial surface exposed, valve leaflets were excised, and adherent thrombus was washed away. Veins were inverted again to turn the endothelial surface back inside the lumen for use as a bypass conduit. Results: Inversion vein harvesting and arterial bypass were completed in 24 (89%) of 27 patients; 2 patients were treated with synthetic grafts because of small GSVs. Another patient was found after vein harvesting to have inadequate arterial outflow despite a good quality conduit. The average vein length was 45±10 cm; a mean 4±1 incisions were made, including those for arterial exposure. Incisions made to divide vein tributaries averaged 2 cm in length. Duration of vein harvesting was 25 minutes (range 5–80). Wound complications were minor (2 hematomas, 2 cases of erythema, 2 seromas). Of 6 grafts that occluded after 30 days, 5 involved small-diameter vein grafts (< 3.5 mm). At a mean 12 months, primary and assisted primary graft patency rates were 88% (14/16) and 94% (15/16), respectively, for grafts with minimum diameters ≥4 mm versus 38% (3/8) primary patency for veins < 4 mm (n=8, p < 0.001). The limb salvage rate was 92% (22/24). Conclusions: Over-the-wire inversion saphenectomy is a simple and reliable minimally invasive technique for arterial bypass. Incisions are small and cosmetically superior to those of the traditional long incision method. One-year follow-up suggests that grafts harvested by inversion technique have excellent durability when the minimum vein diameter is ≥4 mm, as determined by preoperative vein mapping.
- Open Access
- 1 June 2003
- Published by American Medical Association (AMA) in Archives of Surgery
- Vol. 138 (6) , 651-656
Morphologic Changes and Outcome Following Endovascular Abdominal Aortic Aneurysm Repair as a Function of Aneurysm Size
Hypothesis Small infrarenal abdominal aortic aneurysms have a more favorable clinical and morphologic outcome compared with medium and large abdominal aortic aneurysms following endovascular aneurysm repair(EVAR). Design A prospective clinical series of 206 patients undergoing elective EVAR between 1996 and 2001. Setting A tertiary care academic health center. Patients Patients were grouped according to aneurysm size: small (60 mm). Interventions Primary EVAR and secondary procedures to secure fixation of the stent graft and surgical conversions. Main Outcome Measures Aneurysm diameter, endoleaks, and long-term morphologic changes were analyzed postoperatively with 3-dimensional reconstructions of computed tomographic angiograms. Results Groups were similar in age, comorbidities, and follow-up (mean ± SD, 32.1 ± 11.8 months). There were 30 small aneurysms, 92 medium aneurysms, and 84 large aneurysms, with a mean size of 45.1 ± 3.7 mm, 53.8 ± 3.1 mm, and 66.1 ± 6.8 mm, respectively (P<.01). There was no significant difference in proximal neck or iliac artery diameter among the 3 groups. The proximal aortic neck length (28.1 ± 11.6 mm [small]; 23.9 ± 11.3 mm [medium]; and 22.1 ± 11.6 mm [large]; P<.05) was significantly shorter in large aneurysms. Furthermore, there was a significant increase (6% [small]; 15% [medium]; and 21% [large]; P<.05) in angulated necks in large aneurysms. Following treatment, aneurysm diameter remained stable in most patients (83% [small]; 82% [medium]; and 83% [large]), with a mean decrease of 2.0 ± 6.5 mm, 2.1 ± 6.1 mm, and 3.7 ± 7.7 mm in each group, respectively (P = .45). There was no difference in the incidence of endoleaks, aneurysm contraction, or aneurysm expansion based on preoperative aneurysm diameter. Secondary procedures were performed in 5 (20%) of 25, 9 (5.2%) of 170, and 5 (36%) of 11 aneurysms that contracted, remained stable, or expanded, respectively, following EVAR (P<.05). Conclusions There is a 15% increase in neck angulation and a 27% decrease in neck length in large compared with small infrarenal abdominal aortic aneurysms, with no difference in outcome. Aneurysms that are stable following EVAR have a significantly lower incidence of requiring secondary procedures.
- 1 June 2003
- Published by American Medical Association (AMA) in Archives of Surgery
- Vol. 138 (6) , 651-656
Open AccessMorphologic Changes and Outcome Following Endovascular Abdominal Aortic Aneurysm Repair as a Function of Aneurysm Size
Hypothesis Small infrarenal abdominal aortic aneurysms have a more favorable clinical and morphologic outcome compared with medium and large abdominal aortic aneurysms following endovascular aneurysm repair(EVAR). Design A prospective clinical series of 206 patients undergoing elective EVAR between 1996 and 2001. Setting A tertiary care academic health center. Patients Patients were grouped according to aneurysm size: small (60 mm). Interventions Primary EVAR and secondary procedures to secure fixation of the stent graft and surgical conversions. Main Outcome Measures Aneurysm diameter, endoleaks, and long-term morphologic changes were analyzed postoperatively with 3-dimensional reconstructions of computed tomographic angiograms. Results Groups were similar in age, comorbidities, and follow-up (mean ± SD, 32.1 ± 11.8 months). There were 30 small aneurysms, 92 medium aneurysms, and 84 large aneurysms, with a mean size of 45.1 ± 3.7 mm, 53.8 ± 3.1 mm, and 66.1 ± 6.8 mm, respectively (P<.01). There was no significant difference in proximal neck or iliac artery diameter among the 3 groups. The proximal aortic neck length (28.1 ± 11.6 mm [small]; 23.9 ± 11.3 mm [medium]; and 22.1 ± 11.6 mm [large]; P<.05) was significantly shorter in large aneurysms. Furthermore, there was a significant increase (6% [small]; 15% [medium]; and 21% [large]; P<.05) in angulated necks in large aneurysms. Following treatment, aneurysm diameter remained stable in most patients (83% [small]; 82% [medium]; and 83% [large]), with a mean decrease of 2.0 ± 6.5 mm, 2.1 ± 6.1 mm, and 3.7 ± 7.7 mm in each group, respectively (P = .45). There was no difference in the incidence of endoleaks, aneurysm contraction, or aneurysm expansion based on preoperative aneurysm diameter. Secondary procedures were performed in 5 (20%) of 25, 9 (5.2%) of 170, and 5 (36%) of 11 aneurysms that contracted, remained stable, or expanded, respectively, following EVAR (P<.05). Conclusions There is a 15% increase in neck angulation and a 27% decrease in neck length in large compared with small infrarenal abdominal aortic aneurysms, with no difference in outcome. Aneurysms that are stable following EVAR have a significantly lower incidence of requiring secondary procedures.
- 1 February 2003
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 10 (1) , 2-9
Early and Late Functional Outcome Assessments Following Endovascular and Open Aneurysm Repair
L l Purpose: To compare early and late functional outcomes, as well as survival and recovery, following endovascular or open repair of abdominal aortic aneurysm (AAA). Methods: Between 1996 and 2000, 294 patients underwent AAA repair (141 open and 153 endovascular); 57 patients from each group had 12-month follow-up for functional out- come assessment. Recovery was measured as hospital length of stay, skilled nursing re- quirement, and hospital readmission within 1 year to determine cumulative hospital utili- zation. Early (,6 months) functional outcomes were measured by activity level and convalescence days following surgery. Late (.6 months) functional outcomes were mea- sured as ambulation, independent living, and employment status pre- and postoperatively. Results: Operative mortality for open repair was 5 (3.5%) compared to 1 (0.6%) after an endovascular procedure (p,0.05). The endovascular group had a shorter hospital stay (2.862.8 versus 8.364.5 days) and fewer skilled nursing requirements (0% versus 26%; p,0.001). Cumulative hospital utilization over 12 months was 3.8 days for endovascular patients and 13.8 days for open repair (p,0.001). Recovery time was 99.3684.1 days (range 14-365) in conventionally treated patients and 32.1643.5 days (range 7-180) in the stent- graft group (p,0.001). At 6 months, 43 (75%) open and 54 (95%) endovascular patients had full recovery (p,0.01). Activity levels decreased in 13 (23%) open and 3 (5%) endo- vascular patients after surgery (p,0.01). There were no differences in ambulation, inde- pendent living, or employment status before and after treatment. Conclusions: Periprocedural survival following aneurysm repair is improved with endo- vascular grafting compared to open surgery, and recovery is more rapid, with a 78% re- duction in total hospital days. Early functional outcomes are markedly improved with en- dovascular repair, while there is no difference in late functional outcomes between the procedures. J Endovasc Ther 2003;10:2-9
- 1 February 2003
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 10 (1) , 2-9
Early and Late Functional Outcome Assessments Following Endovascular and Open Aneurysm Repair
L l Purpose: To compare early and late functional outcomes, as well as survival and recovery, following endovascular or open repair of abdominal aortic aneurysm (AAA). Methods: Between 1996 and 2000, 294 patients underwent AAA repair (141 open and 153 endovascular); 57 patients from each group had 12-month follow-up for functional out- come assessment. Recovery was measured as hospital length of stay, skilled nursing re- quirement, and hospital readmission within 1 year to determine cumulative hospital utili- zation. Early (,6 months) functional outcomes were measured by activity level and convalescence days following surgery. Late (.6 months) functional outcomes were mea- sured as ambulation, independent living, and employment status pre- and postoperatively. Results: Operative mortality for open repair was 5 (3.5%) compared to 1 (0.6%) after an endovascular procedure (p,0.05). The endovascular group had a shorter hospital stay (2.862.8 versus 8.364.5 days) and fewer skilled nursing requirements (0% versus 26%; p,0.001). Cumulative hospital utilization over 12 months was 3.8 days for endovascular patients and 13.8 days for open repair (p,0.001). Recovery time was 99.3684.1 days (range 14-365) in conventionally treated patients and 32.1643.5 days (range 7-180) in the stent- graft group (p,0.001). At 6 months, 43 (75%) open and 54 (95%) endovascular patients had full recovery (p,0.01). Activity levels decreased in 13 (23%) open and 3 (5%) endo- vascular patients after surgery (p,0.01). There were no differences in ambulation, inde- pendent living, or employment status before and after treatment. Conclusions: Periprocedural survival following aneurysm repair is improved with endo- vascular grafting compared to open surgery, and recovery is more rapid, with a 78% re- duction in total hospital days. Early functional outcomes are markedly improved with en- dovascular repair, while there is no difference in late functional outcomes between the procedures. J Endovasc Ther 2003;10:2-9
- 1 June 2002
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 9 (3) , 269-276
The First 150 Endovascular AAA Repairs at a Single Institution:How Steep Is the Learning Curve?
Subscription and open access journals from SAGE Publishing, the world's leading independent academic publisher.
- 1 June 2002
- Published by International Society of Endovascular Specialists in Journal of Endovascular Therapy
- Vol. 9 (3) , 269-276
The First 150 Endovascular AAA Repairs at a Single Institution:How Steep Is the Learning Curve?
Subscription and open access journals from SAGE Publishing, the world's leading independent academic publisher.
- 1 June 2002
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 9 (3) , 255-261
Open versus Endovascular AAA Repair in Patients Who are Morphological Candidates for Endovascular Treatment
Purpose: To compare the outcomes of open versus endovascular repair of abdominal aortic aneurysm (AAA) in a cohort of patients who fulfill morphological criteria for endovascular repair. Methods: A retrospective review of 229 consecutive AAA patients treated over a 3-year period identified 149 patients who were candidates for endovascular repair based on preoperative computed tomography and angiography. Of the 149 patients, 79 (68 men; mean age 74 ± 8 years) underwent endovascular repair with the AneuRx stent-graft; the remaining 70 (56 men; mean age 72 ± 8 years) had open repair. Short-term outcome measures were 30-day mortality and procedure-related morbidity, length of stay in the intensive care unit and hospital, intraoperative blood loss, interval to oral diet, and time to ambulation. Long-term outcome measures included death and secondary procedures. Results: There was no difference in the 30-day mortality between endovascular repair (2, 2.5%) and open repair (2, 2.9%), even though endovascular patients had more comorbidities (p<0.05). Overall length of stay was reduced for endovascular patients (3.9 ± 2.4 days versus 7.7 ± 3.1 days for surgical patients, p<0.0001). Fewer endograft patients had complications (24% versus 40% for open repair, p<0.05), and the severity of these complications was less, as evidenced by the shorter hospital stays for endovascular patients with complications compared to conventionally treated patients with complications (6.7 ± 2.4 days versus 22.5 ± 35.2 days, p<0.05). There were no aneurysm ruptures or late surgical conversions in either group. Conclusions: Patients with AAA who were endograft candidates but who were treated with open repair experienced more morbidity and had more complications than patients treated with stent-grafts. Despite increased comorbidities in the endograft patients, there was no increase in mortality compared to open repair. Both treatments required secondary procedures and appeared to be equally effective in preventing aneurysm rupture up to 3 years.
- 1 June 2002
- Published by SAGE Publications in Journal of Endovascular Therapy
- Vol. 9 (3) , 255-261
Open versus Endovascular AAA Repair in Patients Who are Morphological Candidates for Endovascular Treatment
Purpose: To compare the outcomes of open versus endovascular repair of abdominal aortic aneurysm (AAA) in a cohort of patients who fulfill morphological criteria for endovascular repair. Methods: A retrospective review of 229 consecutive AAA patients treated over a 3-year period identified 149 patients who were candidates for endovascular repair based on preoperative computed tomography and angiography. Of the 149 patients, 79 (68 men; mean age 74 ± 8 years) underwent endovascular repair with the AneuRx stent-graft; the remaining 70 (56 men; mean age 72 ± 8 years) had open repair. Short-term outcome measures were 30-day mortality and procedure-related morbidity, length of stay in the intensive care unit and hospital, intraoperative blood loss, interval to oral diet, and time to ambulation. Long-term outcome measures included death and secondary procedures. Results: There was no difference in the 30-day mortality between endovascular repair (2, 2.5%) and open repair (2, 2.9%), even though endovascular patients had more comorbidities (p<0.05). Overall length of stay was reduced for endovascular patients (3.9 ± 2.4 days versus 7.7 ± 3.1 days for surgical patients, p<0.0001). Fewer endograft patients had complications (24% versus 40% for open repair, p<0.05), and the severity of these complications was less, as evidenced by the shorter hospital stays for endovascular patients with complications compared to conventionally treated patients with complications (6.7 ± 2.4 days versus 22.5 ± 35.2 days, p<0.05). There were no aneurysm ruptures or late surgical conversions in either group. Conclusions: Patients with AAA who were endograft candidates but who were treated with open repair experienced more morbidity and had more complications than patients treated with stent-grafts. Despite increased comorbidities in the endograft patients, there was no increase in mortality compared to open repair. Both treatments required secondary procedures and appeared to be equally effective in preventing aneurysm rupture up to 3 years.
- 1 August 2001
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 220 (2) , 475-483
Prediction of Aortoiliac Stent-Graft Length: Comparison of Measurement Methods
To determine the accuracy of helical computed tomography (CT), projectional angiography derived from CT angiography, and intravascular ultrasonographic withdrawal (IUW) length measurements for predicting appropriate aortoiliac stent-graft length. Helical CT data from 33 patients were analyzed before and after endovascular repair of abdominal aortic aneurysm (Aneuryx graft, n = 31; Excluder graft, n = 2). The aortoiliac length of the median luminal centerline (MLC) and the shortest path (SP) that remained at least one common iliac arterial radius away from the vessel wall were calculated. Conventional angiographic measurements were simulated from CT data as the length of the three-dimensional MLC projected onto four standard viewing planes. These predeployment lengths and IUW length, available in 24 patients, were compared with the aortoiliac arterial length after stent-graft deployment. The mean error values of SP, MLC, the maximum projected MLC, and IUW were -2.1 mm +/- 4.6 (SD) (P =.013), 9.8 mm +/- 6.8 (P <.001), -5.2 mm +/- 7.8 (P <.001), and -14.1 mm +/- 9.3 (P <.001), respectively. The preprocedural prediction of the postprocedural aortoiliac length with the SP was significantly more accurate than that with the MLC (P <.001), maximum projected MLC (P <.001), and IUW (P <.001). The shortest aortoiliac path length maintaining at least one radius distance from the vessel wall most accurately enabled stent-graft length prediction for 31 AneuRx and two Excluder stent-grafts.
- 1 August 2001
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 220 (2) , 475-483
Prediction of Aortoiliac Stent-Graft Length: Comparison of Measurement Methods
To determine the accuracy of helical computed tomography (CT), projectional angiography derived from CT angiography, and intravascular ultrasonographic withdrawal (IUW) length measurements for predicting appropriate aortoiliac stent-graft length. Helical CT data from 33 patients were analyzed before and after endovascular repair of abdominal aortic aneurysm (Aneuryx graft, n = 31; Excluder graft, n = 2). The aortoiliac length of the median luminal centerline (MLC) and the shortest path (SP) that remained at least one common iliac arterial radius away from the vessel wall were calculated. Conventional angiographic measurements were simulated from CT data as the length of the three-dimensional MLC projected onto four standard viewing planes. These predeployment lengths and IUW length, available in 24 patients, were compared with the aortoiliac arterial length after stent-graft deployment. The mean error values of SP, MLC, the maximum projected MLC, and IUW were -2.1 mm +/- 4.6 (SD) (P =.013), 9.8 mm +/- 6.8 (P <.001), -5.2 mm +/- 7.8 (P <.001), and -14.1 mm +/- 9.3 (P <.001), respectively. The preprocedural prediction of the postprocedural aortoiliac length with the SP was significantly more accurate than that with the MLC (P <.001), maximum projected MLC (P <.001), and IUW (P <.001). The shortest aortoiliac path length maintaining at least one radius distance from the vessel wall most accurately enabled stent-graft length prediction for 31 AneuRx and two Excluder stent-grafts.