Prediction of Aortoiliac Stent-Graft Length: Comparison of Measurement Methods
Authors:
- Bradley B. HillBHBradley B. Hill
- David S. PaikDPDavid S. Paik
- Kerstin PetzKPKerstin Petz
- Sandy NapelSNSandy Napel
- Christopher K. ZarinsCZChristopher K. Zarins
- Geoffrey D. RubinGRGeoffrey D. Rubin
- 1 August 2001
- journal article
- research article
- Published by Radiological Society of North America (RSNA) in Radiology
- Vol. 220 (2) , 475-483
Abstract
To determine the accuracy of helical computed tomography (CT), projectional angiography derived from CT angiography, and intravascular ultrasonographic withdrawal (IUW) length measurements for predicting appropriate aortoiliac stent-graft length. Helical CT data from 33 patients were analyzed before and after endovascular repair of abdominal aortic aneurysm (Aneuryx graft, n = 31; Excluder graft, n = 2). The aortoiliac length of the median luminal centerline (MLC) and the shortest path (SP) that remained at least one common iliac arterial radius away from the vessel wall were calculated. Conventional angiographic measurements were simulated from CT data as the length of the three-dimensional MLC projected onto four standard viewing planes. These predeployment lengths and IUW length, available in 24 patients, were compared with the aortoiliac arterial length after stent-graft deployment. The mean error values of SP, MLC, the maximum projected MLC, and IUW were -2.1 mm +/- 4.6 (SD) (P =.013), 9.8 mm +/- 6.8 (P <.001), -5.2 mm +/- 7.8 (P <.001), and -14.1 mm +/- 9.3 (P <.001), respectively. The preprocedural prediction of the postprocedural aortoiliac length with the SP was significantly more accurate than that with the MLC (P <.001), maximum projected MLC (P <.001), and IUW (P <.001). The shortest aortoiliac path length maintaining at least one radius distance from the vessel wall most accurately enabled stent-graft length prediction for 31 AneuRx and two Excluder stent-grafts.Keywords
This publication has 18 references indexed in Scilit:
- Automated flight path planning for virtual endoscopyMedical Physics, 1998
- Imaging Modalities for Aortic EndograftingJournal of Endovascular Surgery, 1997
- Preliminary clinical outcome and imaging criterion for endovascular prosthesis development in high-risk patients who have aortoiliac and traumatic arterial lesionsJournal of Vascular Surgery, 1996
- Comparison of magnetic resonance imaging measurements of abdominal aortic aneurysms with measurements obtained by other imaging techniques and intraoperative measurements: Possible implications for endovascular graftingJournal of Vascular Surgery, 1996
- CT-angiography of abdominal aortic aneurysms after transfemoral endovascular aneurysm managementEuropean Journal of Vascular and Endovascular Surgery, 1996
- In vivo validation of intravascular ultrasound length measurements using a motorized transducer pullback systemThe American Journal of Cardiology, 1996
- Abdominal Aortic AneurysmNew England Journal of Medicine, 1993
- Marching cubes: A high resolution 3D surface construction algorithmACM SIGGRAPH Computer Graphics, 1987
- Conventional repair of abdominal aortic aneurysm in the high-risk patient: A plea for abandonment of nonresective treatmentJournal of Vascular Surgery, 1986
- Abdominal Aortic Aneurysm and Coronary Artery DiseaseArchives of Surgery, 1981