Stefan Rosén
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Stefan Rosén has a total of 19 co-authors. Here are the top co-authors by number of shared publications:
A. Larson
Department of Physics I, Royal Institute of Technology (KTH), S-100 44 Stockholm, Sweden
1 shared publicationA. Le Padellec
Department of Physics, Stockholm University, P.O. Box 6730, S-113 85 Stockholm, Sweden
1 shared publicationC. Stromholm
Department of Physics I, Royal Institute of Technology (KTH), S-100 44 Stockholm, Sweden
1 shared publication- Daniel Fischer
Physics Department and LAMOR, Missouri University of Science & Technology, Rolla, MO 65409, USA
1 shared publication - Gordon H. Dunn
JILA, National Institute of Standards and Technology and University of Colorado, Boulder, Colorado 80309-0440
1 shared publication - Henning T. Schmidt
Department of Physics, Stockholm University, Stockholm SE-10691, Sweden
1 shared publication
Latest Publications
- 1 November 2007
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 78 (11) , 113301
Operating a triple stack microchannel plate-phosphor assembly for single particle counting in the 12–300K temperature range
An assembly consisting of a stack of three microchannel plates (MCPs) and a phosphor screen anode has been operated over the temperature range from . We report on measurements at (using an alpha source) and with dark counts only . Without any particle source, the MCP bias current decreased by a factor of when the temperature was lowered from . Using the alpha source, and a photomultiplier tube (PMT) to monitor the phosphor screen anode, we first observed an increase in the decay time of the phosphor from when the temperature was decreased from while the decay time then decreased and reached a value of at . The pulse height distribution from the PMT was measured between 300 and and shows a spectrum typical for a MCP phosphor setup at and but is strongly degraded for intermediate temperatures. We conclude that the present MCP-phosphor detector assembly is well suited for position-sensitive particle counting operation at temperatures down to at least even for count rates beyond . This result is crucial and an important part of ongoing developments of new instrumentation for investigations of, e.g., interactions involving complex molecular ions with internal quantum state control.- 1 November 2007
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 78 (11) , 113301
Operating a triple stack microchannel plate-phosphor assembly for single particle counting in the 12–300K temperature range
An assembly consisting of a stack of three microchannel plates (MCPs) and a phosphor screen anode has been operated over the temperature range from . We report on measurements at (using an alpha source) and with dark counts only . Without any particle source, the MCP bias current decreased by a factor of when the temperature was lowered from . Using the alpha source, and a photomultiplier tube (PMT) to monitor the phosphor screen anode, we first observed an increase in the decay time of the phosphor from when the temperature was decreased from while the decay time then decreased and reached a value of at . The pulse height distribution from the PMT was measured between 300 and and shows a spectrum typical for a MCP phosphor setup at and but is strongly degraded for intermediate temperatures. We conclude that the present MCP-phosphor detector assembly is well suited for position-sensitive particle counting operation at temperatures down to at least even for count rates beyond . This result is crucial and an important part of ongoing developments of new instrumentation for investigations of, e.g., interactions involving complex molecular ions with internal quantum state control.- Open Access
- 20 September 1998
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 505 (1) , 459-465
Branching Fractions in Dissociative Recombination of CH2+
The absolute cross section and branching ratios for dissociative recombination of CH2+ with electrons have been measured by means of the heavy-ion storage ring CRYRING. Contrary to what has been previously believed, recombination of CH2+ is dominated by the three-body channel C + H + H (63%), whereas breakup into the CH + H and C + H2 channels occurs with branching ratios of 25% and 12%, respectively. The thermal rate coefficient for dissociative recombination at 300 K is 6.4 × 10-7 cm3 s-1, which is higher by a factor of 2.5 than the value used in modeling dark molecular clouds. The low CH production and the high production of energetic carbon atoms could be favorable factors for the turbulence model to explain the large abundance of interstellar CH+. The cross section for dissociative excitation was also measured and found to be in good agreement with results from a crossed electron-ion beam experiment. © 1998. The American Astronomical Society. All rights reserved
- 20 September 1998
- Published by American Astronomical Society in The Astrophysical Journal
- Vol. 505 (1) , 459-465
Open AccessBranching Fractions in Dissociative Recombination of CH2+
The absolute cross section and branching ratios for dissociative recombination of CH2+ with electrons have been measured by means of the heavy-ion storage ring CRYRING. Contrary to what has been previously believed, recombination of CH2+ is dominated by the three-body channel C + H + H (63%), whereas breakup into the CH + H and C + H2 channels occurs with branching ratios of 25% and 12%, respectively. The thermal rate coefficient for dissociative recombination at 300 K is 6.4 × 10-7 cm3 s-1, which is higher by a factor of 2.5 than the value used in modeling dark molecular clouds. The low CH production and the high production of energetic carbon atoms could be favorable factors for the turbulence model to explain the large abundance of interstellar CH+. The cross section for dissociative excitation was also measured and found to be in good agreement with results from a crossed electron-ion beam experiment. © 1998. The American Astronomical Society. All rights reserved