Petr Boček
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Petr Boček has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
Petr Gebauer
Institute of Analytical Chemistry Academy of Sciences of the Czech Republic Brno Czech Republic
19 shared publicationsZdena Malá
Institute of Analytical Chemistry, Academy of Sciences of the Czech Republic, Brno, Czech Republic
12 shared publications- Petr Gebauer
Institute of Analytical Chemistry of the Czech Academy of Sciences, v.v.i., Veveří 97, CZ-602 00 Brno, Czech Republic
8 shared publications Andrea Šlampová
Institute of Analytical Chemistry of the Czech Academy of Sciences, v. v. i., Veveří 97, CZ-60200 Brno, Czech Republic
7 shared publicationsJozef L. Beckers
Eindhoven University of Technology, Department of Chemistry, Eindhoven, The Netherlands
7 shared publications- Jozef L. Beckers
Eindhoven University of Technology, Department of Chemistry (SPO), Eindhoven, The Netherlands
4 shared publications
Latest Publications
- 1 August 2015
- Published by Elsevier in Analytica Chimica Acta
- Vol. 887, 92-100
Quantitative aspects of electrolysis in electromembrane extractions of acidic and basic analytes
- 1 August 2015
- Published by Elsevier in Analytica Chimica Acta
- Vol. 887, 92-100
Quantitative aspects of electrolysis in electromembrane extractions of acidic and basic analytes
- 9 October 2014
- Published by Wiley in Electrophoresis
- Vol. 36 (1) , 15-35
Contemporary sample stacking in analytical electrophoresis
This contribution is a methodological review of the publications about the topic from the last 2 years. Therefore, it is primarily organized according to the methods and procedures used in surveyed papers and the origin and type of sample and specification of analytes form the secondary structure. The introductory part about navigation in the architecture of stacking brings a brief characterization of the various stacking methods, with the description of mutual links to each other and important differences among them. The main body of the article brings a survey of publications organized according to main principles of stacking and then according to the origin and type of the sample. Provided that the paper cited gave explicitly the relevant data, information about the BGE(s) used, procedure, detector employed, and reached LOD and/or concentration effect is given. The papers where the procedure used is a combination of diverse fragments and parts of various stacking techniques are mentioned in a special section on combined techniques. The concluding remarks in the final part of the review evaluate present state of art and the trends of sample stacking in CE.
- 9 October 2014
- Published by Wiley in Electrophoresis
- Vol. 36 (1) , 15-35
Contemporary sample stacking in analytical electrophoresis
This contribution is a methodological review of the publications about the topic from the last 2 years. Therefore, it is primarily organized according to the methods and procedures used in surveyed papers and the origin and type of sample and specification of analytes form the secondary structure. The introductory part about navigation in the architecture of stacking brings a brief characterization of the various stacking methods, with the description of mutual links to each other and important differences among them. The main body of the article brings a survey of publications organized according to main principles of stacking and then according to the origin and type of the sample. Provided that the paper cited gave explicitly the relevant data, information about the BGE(s) used, procedure, detector employed, and reached LOD and/or concentration effect is given. The papers where the procedure used is a combination of diverse fragments and parts of various stacking techniques are mentioned in a special section on combined techniques. The concluding remarks in the final part of the review evaluate present state of art and the trends of sample stacking in CE.
- 1 July 2013
- Published by Elsevier in Analytica Chimica Acta
- Vol. 787, 10-23
Direct coupling of supported liquid membranes to capillary electrophoresis for analysis of complex samples: A tutorial
- 1 July 2013
- Published by Elsevier in Analytica Chimica Acta
- Vol. 787, 10-23
Direct coupling of supported liquid membranes to capillary electrophoresis for analysis of complex samples: A tutorial
- 3 December 2012
- Published by Wiley in Electrophoresis
- Vol. 34 (1) , 3-18
Contemporary sample stacking in analytical electrophoresis
Sample stacking is a term denoting a multifarious class of methods and their names that are used daily in CE for online concentration of diluted samples to enhance separation efficiency and sensitivity of analyses. The essence of these methods is that analytes present at low concentrations in a large injected sample zone are concentrated into a short and sharp zone (stack) in the separation capillary. Then the stacked analytes are separated and detected. Regardless of the diversity of the stacking electromigration methods, one can distinguish four main principles that form the bases of nearly all of them: (i) Kohlrausch adjustment of concentrations, (ii) pH step, (iii) micellar methods, and (iv) transient ITP. This contribution is a continuation of our previous reviews on the topic and brings an overview of papers published during 2010–2012 and relevant to the mentioned principles (except the last one which is covered by another review in this issue).
- 3 December 2012
- Published by Wiley in Electrophoresis
- Vol. 34 (1) , 3-18
Contemporary sample stacking in analytical electrophoresis
Sample stacking is a term denoting a multifarious class of methods and their names that are used daily in CE for online concentration of diluted samples to enhance separation efficiency and sensitivity of analyses. The essence of these methods is that analytes present at low concentrations in a large injected sample zone are concentrated into a short and sharp zone (stack) in the separation capillary. Then the stacked analytes are separated and detected. Regardless of the diversity of the stacking electromigration methods, one can distinguish four main principles that form the bases of nearly all of them: (i) Kohlrausch adjustment of concentrations, (ii) pH step, (iii) micellar methods, and (iv) transient ITP. This contribution is a continuation of our previous reviews on the topic and brings an overview of papers published during 2010–2012 and relevant to the mentioned principles (except the last one which is covered by another review in this issue).
- 3 December 2012
- Published by Wiley in Electrophoresis
- Vol. 34 (1) , 19-28
Recent progress in analytical capillary isotachophoresis
This review brings a survey of the literature on analytical isotachophoresis (ITP) from the years 2010–2012. It confirms the fact that ITP alone is not used for analyses frequently but that its online combinations with other methods are of paramount importance. This review shows that the inherent features of the technique and first of all its concentrating ability are still unique for reaching high sensitivity and efficient sample cleanup in analytical applications. The part devoted to theory is mostly represented by computer simulations and confirms the power and significance of this approach. The section oriented at instrumentation and techniques shows the advantages of ITP in column combinations and microchip techniques. The chapter reviewing the applications is categorized according to the techniques applied, viz., column switching, on line ITP‐CZE and on‐chip analyses. The final part of the review is devoted to the nearly omnipresent electrophoresis principle of transient isotachophoresis, and to the advantages that it may offer for detection and sampling. In all parts, the significance of the operational conditions is also considered and where possible, the electrolyte system is explicitly presented.
- 3 December 2012
- Published by Wiley in Electrophoresis
- Vol. 34 (1) , 19-28
Recent progress in analytical capillary isotachophoresis
This review brings a survey of the literature on analytical isotachophoresis (ITP) from the years 2010–2012. It confirms the fact that ITP alone is not used for analyses frequently but that its online combinations with other methods are of paramount importance. This review shows that the inherent features of the technique and first of all its concentrating ability are still unique for reaching high sensitivity and efficient sample cleanup in analytical applications. The part devoted to theory is mostly represented by computer simulations and confirms the power and significance of this approach. The section oriented at instrumentation and techniques shows the advantages of ITP in column combinations and microchip techniques. The chapter reviewing the applications is categorized according to the techniques applied, viz., column switching, on line ITP‐CZE and on‐chip analyses. The final part of the review is devoted to the nearly omnipresent electrophoresis principle of transient isotachophoresis, and to the advantages that it may offer for detection and sampling. In all parts, the significance of the operational conditions is also considered and where possible, the electrolyte system is explicitly presented.
- 21 June 2012
- Published by Wiley in Electrophoresis
- Vol. 33 (17) , 2695-2702
Electrokinetic injection across supported liquid membranes: New sample pretreatment technique for online coupling to capillary electrophoresis. Direct analysis of perchlorate in biological samples
A simple and sensitive method for quantifying perchlorate in biological samples using CE and capacitively coupled contactless conductivity detection was developed. An online combination of a supported liquid membrane, an inert polypropylene membrane impregnated with 1-hexanol, and electrokinetic injection of perchlorate across the supported liquid membrane directly into the separation capillary reduced the need for laborious sample pretreatment procedures, resulting in a cheap and rapid method with low LODs capability. Baseline separation of perchlorate and other anions in biological samples was achieved in background electrolyte solution consisting of 15 mM nicotinic acid and 1 mM 3-(N,N-dimethylmyristylammonio)propanesulfonate at pH 3.3. The analytical method showed excellent parameters in terms of reproducibility; RSD values for peak areas and corrected migration times at a spiked concentration of 100 μg/L of perchlorate were below 10 and 0.4%, respectively. Linear calibration curves were obtained for perchlorate in the concentration range 10–1000 μg/L (r2 >0.999) with LODs between 2 and 5 μg/L for human urine, breast milk, serum, cow's milk, and red wine. Recoveries at 25 μg/L of perchlorate were between 97 and 106% for all biological samples. The low LODs rivaling those of presently used analytical methods support the use of this method for quantification of perchlorate in biological samples in the future.
- 21 June 2012
- Published by Wiley in Electrophoresis
- Vol. 33 (17) , 2695-2702
Electrokinetic injection across supported liquid membranes: New sample pretreatment technique for online coupling to capillary electrophoresis. Direct analysis of perchlorate in biological samples
A simple and sensitive method for quantifying perchlorate in biological samples using CE and capacitively coupled contactless conductivity detection was developed. An online combination of a supported liquid membrane, an inert polypropylene membrane impregnated with 1-hexanol, and electrokinetic injection of perchlorate across the supported liquid membrane directly into the separation capillary reduced the need for laborious sample pretreatment procedures, resulting in a cheap and rapid method with low LODs capability. Baseline separation of perchlorate and other anions in biological samples was achieved in background electrolyte solution consisting of 15 mM nicotinic acid and 1 mM 3-(N,N-dimethylmyristylammonio)propanesulfonate at pH 3.3. The analytical method showed excellent parameters in terms of reproducibility; RSD values for peak areas and corrected migration times at a spiked concentration of 100 μg/L of perchlorate were below 10 and 0.4%, respectively. Linear calibration curves were obtained for perchlorate in the concentration range 10–1000 μg/L (r2 >0.999) with LODs between 2 and 5 μg/L for human urine, breast milk, serum, cow's milk, and red wine. Recoveries at 25 μg/L of perchlorate were between 97 and 106% for all biological samples. The low LODs rivaling those of presently used analytical methods support the use of this method for quantification of perchlorate in biological samples in the future.
- 11 May 2011
- Published by Wiley in Electrophoresis
- Vol. 32 (12) , 1500-1507
Important electromigration effects of carbon dioxide in capillary electrophoresis at high pH
This paper deals with unwanted effects of carbonate in capillary zone electrophoretic analyses of anions in alkaline BGEs with indirect UV absorption and conductivity detection. Computer simulations and experimental study of selected model systems have shown that carbon dioxide absorbed from air into BGEs and samples induce important electrophoretic effects like formation of new additional zones and/or boundaries that may further induce strong and pronounced temporary changes in the migration of analytes. Examples are reduction of the pH of alkaline BGEs around pH 11 by up to 1 unit or formation of a pronounced detectable carbon dioxide peak comparable with peaks of analytes at 1 mM level. The higher the pH of the BGE, the stronger these effects and the broader their spectrum, involving (i) changes of effective mobilities and selectivity due to changes in pH of the BGE, (ii) occurrence of additional system zones appearing in form of peaks, dips or more complex disturbances in the detection signal, (iii) temporary interactions with the sample components and subsequent modification of the separation process and of its result. This paper reveals all these effects and brings the knowledge necessary to prevent problems with qualitative and quantitative evaluation of the analysis results.
- 11 May 2011
- Published by Wiley in Electrophoresis
- Vol. 32 (12) , 1500-1507
Important electromigration effects of carbon dioxide in capillary electrophoresis at high pH
This paper deals with unwanted effects of carbonate in capillary zone electrophoretic analyses of anions in alkaline BGEs with indirect UV absorption and conductivity detection. Computer simulations and experimental study of selected model systems have shown that carbon dioxide absorbed from air into BGEs and samples induce important electrophoretic effects like formation of new additional zones and/or boundaries that may further induce strong and pronounced temporary changes in the migration of analytes. Examples are reduction of the pH of alkaline BGEs around pH 11 by up to 1 unit or formation of a pronounced detectable carbon dioxide peak comparable with peaks of analytes at 1 mM level. The higher the pH of the BGE, the stronger these effects and the broader their spectrum, involving (i) changes of effective mobilities and selectivity due to changes in pH of the BGE, (ii) occurrence of additional system zones appearing in form of peaks, dips or more complex disturbances in the detection signal, (iii) temporary interactions with the sample components and subsequent modification of the separation process and of its result. This paper reveals all these effects and brings the knowledge necessary to prevent problems with qualitative and quantitative evaluation of the analysis results.
- 3 December 2010
- Published by Wiley in Electrophoresis
- Vol. 32 (1) , 83-89
Recent progress in analytical capillary isotachophoresis
Capillary ITP is currently used as one of the most important tools for preseparation and preconcentration of trace analytes in complex or diluted samples. This contribution is a continuation of a series of regularly published reviews on the topic and covers the last 2 years. It brings a survey of related literature organized into following sections: theory and methodology, instrumentation and techniques, and applications.
- 3 December 2010
- Published by Wiley in Electrophoresis
- Vol. 32 (1) , 83-89
Recent progress in analytical capillary isotachophoresis
Capillary ITP is currently used as one of the most important tools for preseparation and preconcentration of trace analytes in complex or diluted samples. This contribution is a continuation of a series of regularly published reviews on the topic and covers the last 2 years. It brings a survey of related literature organized into following sections: theory and methodology, instrumentation and techniques, and applications.
- 1 December 2010
- Published by Wiley in Electrophoresis
- Vol. 32 (1) , 116-126
Contemporary sample stacking in analytical electrophoresis
Sample stacking is of vital importance for analytical CE since it may bring the required sensitivity of analyses. A lot of new relevant papers are published every year and regular surveys seem to be very helpful for experts and practitioners. The contribution presented here is a continuation of a series of regularly published reviews on the topic and covers the last two years. It brings a survey of related literature organized, in accord with the main principle used in the procedure published, in the following mainstream sections: Kohlrausch adjustment of concentrations, pH step, micellar systems and combined techniques. Each part covers literature sorted according to the field of application as, e.g. clinical, pharmaceutical, food, environmental, etc.
- 1 December 2010
- Published by Wiley in Electrophoresis
- Vol. 32 (1) , 116-126
Contemporary sample stacking in analytical electrophoresis
Sample stacking is of vital importance for analytical CE since it may bring the required sensitivity of analyses. A lot of new relevant papers are published every year and regular surveys seem to be very helpful for experts and practitioners. The contribution presented here is a continuation of a series of regularly published reviews on the topic and covers the last two years. It brings a survey of related literature organized, in accord with the main principle used in the procedure published, in the following mainstream sections: Kohlrausch adjustment of concentrations, pH step, micellar systems and combined techniques. Each part covers literature sorted according to the field of application as, e.g. clinical, pharmaceutical, food, environmental, etc.