JBJozef L. Beckers

Jozef L. Beckers

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Jozef L. Beckers has a total of 3 co-authors. Here are the top co-authors by number of shared publications:

  • Petr Boček

    Institute of Analytical Chemistry Academy of Sciences of the Czech Republic Brno Czech Republic

    4 shared publications
  • Mariëtte T. Ackermans

    Academic Medical Center, Laboratory of Endocrinology and Radio Chemistry, Amsterdam, The Netherlands

    1 shared publication
  • Petr Gebauer

    Institute of Analytical Chemistry of the Czech Academy of Sciences, v.v.i., Veveří 97, CZ-602 00 Brno, Czech Republic

    1 shared publication

Latest Publications

  • Calibrationless quantitative analysis by indirect UV absorbance detection in capillary zone electrophoresis: The concept of the conversion factor

    by Jozef L. Beckers, Petr Boček

    A new, fast and efficient procedure is described for the simultaneous quantitative analysis of various non‐UV absorbing species in a sample, by capillary zone electrophoresis with indirect UV absorbance detection. The procedure is based on the concept of the conversion factor (CF). The CF of an analyte is defined as the ratio of the measured temporal peak area and the product of its migration time and transfer ratio (TR). Thus defined, the CF is of general validity for all analytes separated and detected in a given background electrolyte (BGE), since it has the same value for the same amounts of various analytes. If a sample is enriched with a known concentration of a standard component and analyzed by CZE, the CF of this standard component can be calculated and then the concentrations of all other analytes can be determined, without the use of any calibration graph. The individual TRs can be determined a priori from tabulated ionic mobilities and pK values of the analytes and of the constituents of the BGE or, for strong analytes, by using experimental data from the electropherogram of the analysis itself. The practical procedure of the analysis includes enrichment of the sample with a known quantity of a suitable standard and a single CZE run of the resulting mixture. The injected volume does not need to be known and thus the procedure also eliminates the injection error. The proposed procedure has been verified experimentally and reproducible and accurate values were obtained by using four different CZE apparatus for the analyses of standard mixtures of cations in three different BGEs.


  • Capillary zone electrophoresis in methanol: Migration behavior and background electrolytes

    by Jozef L. Beckers, Mariëtte T. Ackermans, Petr Boček

    Nonaqueous (NA) solutions are often used as background electrolytes (BGEs) and NA solvents are added to aqueous BGEs as organic modifiers in capillary zone electrophoresis (CZE), in order to optimize the separations. This can be tricky, however, because the pH* and pK* concepts may be totally different in NA solvents, whereas often less knowledge is available concerning phenomena, such as system zones, applying NA solvents. In this paper, the concepts of pH* and pK* are considered for methanol as a solvent and pK* values are determined for several components in mixtures of water and methanol. With a mathematical model, adapted for calculations in methanol, parameters are calculated describing the fronting or tailing character of peaks and the question of peaks or dips, and the existence of system zones is discussed for pure methanol as a solvent. These aspects are experimentally verified, applying BGEs useful for the separation of cationic species in the indirect UV mode. It can be concluded that the mathematical model developed for aqueous BGEs is applicable to BGEs in methanol, too, and that the behavior of BGEs in methanol is comparable with that in water concerning the fronting or tailing character of peaks and the question of peaks and dips, although the mobilities and pK values can change significantly.


  • Ampholytes as background electrolytes in capillary zone electrophoresis: Sense or nonsense? Histidine as a model ampholyte

    by Jozef L. Beckers

    A lot of phenomena, occuring in capillary zone electrophoresis (CZE), are linked with the ionic concentration of the background electrolyte (BGE). If weak bases and acids are used as BGEs in CZE, at a pH where they are scarcely ionized, the ionic concentration of the BGE is very low and this brings a strong peak broadening, limited sample stacking and low sample load. Because the electromigration dispersion increases extremely, moreover, the existence of low‐conductivity BGEs in CZE is a contradiction in terms. The behavior of ampholytes as BGE in CZE is examined, by means of histidine as a model ampholyte. For BGEs consisting of histidine, important parameters, including the ionic concentrations, buffer capacity, transfer ratio, and the indicator for electromigration dispersion E1m1/E2m2, are calculated at various pH. Although the transfer ratio is fairly constant over the whole pH traject, the ionic concentration and buffer capacity decrease whereas the electromigration dispersion strongly increases near the pI of histidine. I.e., that ampholytes can be applied as BGEs in CZE, however, just not at pH near their pI value, except as the difference between the pK values of the basic and acidic group, the δpK value, is very small. For ampholytes with a low δpK value or at high concentrations, all the before‐mentioned effects are less fatal, but in that case we can not speak of a real low‐conductivity BGE. If ampholytes are used at pH near their pK values, the use of ampholytes as BGE is not advantageously compared with simple weak bases and acids. This has been confirmed by calculations and experiments.


  • Editorial: Electrophoresis 12/2002

    by Jozef L. Beckers, Petr Gebauer, Petr Boček

  • Window optimization in isotachophoresis superimposed on capillary zone electrophoresis

    by Jozef L. Beckers

    A sample stacking procedure to which a specific combination of electrolyte solutions is applied is isotachophoresis (ITP) superimposed on capillary zone electrophoresis (CZE), a so‐called ITP/CZE system. In ITP/CZE some components migrate in an ITP fashion on top of a background electrolyte, and the other analytes migrate in a zone electrophoretic manner. For such a system, the leading electrolyte consists of a mixture of an ionic species, L1, of high mobility (the leading ion of the ITP system), an ionic species, L2, of low mobility (the coions of the CZE system), and a buffering counterionic species, whereas the terminating solution only contains the ionic species L2 and the buffering counterions. The zones of the components migrating in the ITP/CZE mode are sharp owing to the self‐correcting properties of the zones and the concentrations of the L1 ions of the system. Mobility windows can be calculated, indicating which ions can migrate in the ITP/CZE mode. In this article mobility windows are calculated by applying both strong and weak acids as L1 and L2 ions and it appears that mobility windows can be optimized by chosing different ratios of L1 and L2 as well as different pH values. It is possible to construct very narrow mobility windows, and thereby choose which component of a sample solution can be concentrated, and to what concentration, in a very selective way. The big advantage of ITP/CZE compared with applications such as transient ITP and transient stacking is that the stacked sample ionic species migrate in the ITP mode during the whole experiment; furthermore, they do not destack. Experimentally obtained electropherograms validate the calculated mobility windows for the ITP/CZE mode.