AKAdam Keech

Adam Keech

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Adam Keech has a total of 6 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Impact of Time Between Collection and Collection Method on Human Tear Fluid Osmolarity

    by Adam Keech, Michelle Senchyna, Lyndon Jones

    Aim: To generate data on the variability of tear osmolarity in a control (normal, non-dry eye) and symptomatic dry eye population (Ocular Surface Disease Index: OSDI ≥20). A secondary outcome is the determination of the effect that tear collection technique has on the osmolarity of the sample. Materials and methods: This was a two-phase study that recruited 20 subjects (n = 10 normal, n = 10 dry eye) to evaluate the influence of time between measurements (Phase I) and 30 subjects (n = 15 normal, n = 15 dry eye) to evaluate the influence of collection technique (Phase II). As part of Phase I, serial tear osmolarity measurements were performed on each eye; four separated by 15 min followed by four separated by 1 min, at each of three visits. Phase II compared the consecutive measurement of four in vivo tear samples to four in vitro measurements on tears collected and dispensed from a glass capillary tube. Results: During Phase I, the dry eye group had a significantly higher maximum osmolarity (334.2 ± 25.6 mOsm/L) compared to the normal group (304.0 ± 8.4 mOsm/L, p = 0.002). No significant differences were observed whether collections were performed at 15 or 1 min intervals. During Phase II, the in vivo osmolarity was equivalent to in vitro measurements from glass capillary tube samples for both the dry eye group (323.0 ± 16.7 mOsm/L versus 317.7 ± 24.8, p = 0.496), and for the normal subjects (301.2 ± 7.2 mOsm/L versus 301.9 ± 16.0 mOsm/L, p = 0.884). Conclusion: Symptomatic dry eye subjects exhibited a significantly higher tear osmolarity and variation over time than observed in normal subjects, reflecting the inherent tear film instability of dry eye disease. There was no change in the distribution of tear osmolarity measurements whether tears were collected in rapid succession or given time to equilibrate, and collection method had no impact on tear osmolarity.


  • Repeatability of Pachymetry and Thinnest Point Localization Using a Fourier‐Domain Optical Coherence Tomographer

    by Adam Keech, Trefford Simpson, Lyndon Jones

    Purpose.: To evaluate the repeatability of pachymetry measures at six distinct locations using a Fourier‐domain optical coherence tomographer. The location of the thinnest point was also described using vector analysis, and repeatability of the localization of the thinnest point was calculated. Methods.: The right eye of 25 healthy subjects had 3 images of their right cornea captured using the pachymetry protocol and anterior segment lens of a commercially available Fourier‐domain optical coherence tomographer (RTVue‐100, Optovue, Fremont, CA). The first two images were used to quantify repeatability in the central (2 mm) and paracentral (2–5 mm) cornea. Cartesian coordinates representing the location of the thinnest point were used to determine the mean location in relation to the central cornea. Results.: Mean central thickness was 536.8 ± 31.1 μm, and the mean minimum thickness was 526.4 ± 33.1 μm. The thickest paracentral zone was the superior cornea and the thinnest was the temporal cornea. Intraclass correlation values ranged between 0.969 and 0.996, and the mean coefficient of repeatability was 1.74% across all locations evaluated. The thinnest point was located in the inferior temporal region in 80% of eyes and was an average distance of 1.01 mm from the corneal apex, subtending an angle of 26.7° from the horizontal. Conclusions.: The RTVue‐100 provides a highly repeatable measure of corneal thickness at various locations. The instrument is capable of describing and consistently duplicating the location of the thinnest point of the cornea; however, further comparative work with other clinical imaging modalities is required.


  • Conformational and Quantitative Characterization of Lysozyme Extracted from Galyfilcon and Senofilcon Silicone Hydrogel Contact Lenses

    by Mary-Ann Glasier, Adam Keech, Heather Sheardown, Lakshman N. Subbaraman, Lyndon Jones

    To compare two solvents for retrieval of lysozyme deposited on a silicone hydrogel (SH) contact lens material galyfilcon A (GA; Acuvue Advance). Two buffers used were 50:50 acetonitrile/0.02% trifluoroacetic acid (buffer 1) and 50:50 acetonitrile/50 mM NaOH (buffer 2). Extraction efficiency from GA lenses was 74% (buffer 1) and 83% (buffer 2). Buffer 2 decreased lysozyme activity > buffer 1. Ex vivo GA lenses showed total protein deposition of 2-16 microg/lens with total lysozyme deposition of 0.3-3.9 microg/lens. We have developed a low acid strength extraction buffer that can be used to efficiently extract active lysozyme protein from novel siloxane-based contact lens materials.