Repeatability of Pachymetry and Thinnest Point Localization Using a Fourier‐Domain Optical Coherence Tomographer
- 1 October 2010
- journal article
- research article
- Published by Wiley in Optometry and Vision Science
- Vol. 87 (10) , 736-741
Abstract
Purpose.: To evaluate the repeatability of pachymetry measures at six distinct locations using a Fourier‐domain optical coherence tomographer. The location of the thinnest point was also described using vector analysis, and repeatability of the localization of the thinnest point was calculated. Methods.: The right eye of 25 healthy subjects had 3 images of their right cornea captured using the pachymetry protocol and anterior segment lens of a commercially available Fourier‐domain optical coherence tomographer (RTVue‐100, Optovue, Fremont, CA). The first two images were used to quantify repeatability in the central (2 mm) and paracentral (2–5 mm) cornea. Cartesian coordinates representing the location of the thinnest point were used to determine the mean location in relation to the central cornea. Results.: Mean central thickness was 536.8 ± 31.1 μm, and the mean minimum thickness was 526.4 ± 33.1 μm. The thickest paracentral zone was the superior cornea and the thinnest was the temporal cornea. Intraclass correlation values ranged between 0.969 and 0.996, and the mean coefficient of repeatability was 1.74% across all locations evaluated. The thinnest point was located in the inferior temporal region in 80% of eyes and was an average distance of 1.01 mm from the corneal apex, subtending an angle of 26.7° from the horizontal. Conclusions.: The RTVue‐100 provides a highly repeatable measure of corneal thickness at various locations. The instrument is capable of describing and consistently duplicating the location of the thinnest point of the cornea; however, further comparative work with other clinical imaging modalities is required.Keywords
This publication has 19 references indexed in Scilit:
- Corneal Thickness in a Population-Based, Cross-Sectional Study: The Tehran Eye StudyCornea, 2009
- Repeatability of Corneal Thickness Measured Using an Oculus PentacamOptometry and Vision Science, 2009
- Keratoconus Diagnosis with Optical Coherence Tomography Pachymetry MappingOphthalmology, 2008
- Comparison of Central Corneal Thickness Measurements by Ultrasound Pachymetry, Konan Noncontact Optical Pachymetry, and Orbscan PachymetryCornea, 2008
- Agreement and Repeatability of the Sonogage Ultrasound Pachometer Compared with a Mitutoyo MicrometerOptometry and Vision Science, 2008
- Risk Assessment for Ectasia after Corneal Refractive SurgeryOphthalmology, 2008
- Repeatability and Reproducibility of Pachymetric Mapping with Visante Anterior Segment–Optical Coherence TomographyInvestigative Ophthalmology & Visual Science, 2007
- Pentacam pachometry: comparison with non‐contact specular microscopy on the central cornea and inter‐session repeatability on the peripheral corneaClinical and Experimental Optometry, 2007
- Comparison of residual stromal bed and flap thickness in primary and repeat laser in situ keratomileusis in myopic patientsJournal of Cataract & Refractive Surgery, 2006
- Evaluation of Normal Corneas Using the Scanning-Slit Topography/Pachymetry SystemCornea, 2004