Fabio Nardone
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Fabio Nardone has a total of 7 co-authors. Here are the top co-authors by number of shared publications:
- Andrea Prota
Sezione INFN di Napoli
4 shared publications - Antonio De Luca
Assistant Professor, Dept. of Structural Engineering, Univ. of Naples, Federico II, Via Claudio 21, Naples, P.O. Box I-80125, Italy
2 shared publications - Antonio Nanni
Univ. of Miami
2 shared publications - Gaetano Manfredi
University of Naples Federico II
2 shared publications - Gian Piero Lignola
University of Naples Federico II
2 shared publications - Fabio Matta
Postdoc, Dept. of Civil, Architectural, and Environmental Engineering, Univ. of Miami, 105 McArthur Engineering Bldg., Coral Gables, FL 33146-0630
1 shared publication
Latest Publications
- 1 August 2011
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 15 (4) , 545-556
Analysis of RC Hollow Columns Strengthened with GFRP
Reinforced concrete (RC) hollow piers in bridges withstand high moment and shear demands ensured with reduced mass and lower stress on foundations compared with solid piers. Failure of hollow columns is typically affected by premature buckling of reinforcing bars and concrete cover spalling. At present, no guidelines are available for the design of their upgrade, and few research investigations can be found on hollow columns strengthened by using fiber-reinforced polymer (FRP) materials. This paper discusses an experimental program carried out on purely compressed RC hollow columns externally wrapped with glass-fiber-reinforced polymer (GFRP). Three specimens were tested: one specimen was unstrengthened and used as the benchmark; the other two specimens were GFRP-wrapped with different confining reinforcement ratios. Each specimen was designed according to dated codes (i.e., prior to 1970) accounting only for gravity loads. In particular, steel longitudinal bars cross section and steel tie-spacing were de...
- 1 August 2011
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 15 (4) , 545-556
Analysis of RC Hollow Columns Strengthened with GFRP
Reinforced concrete (RC) hollow piers in bridges withstand high moment and shear demands ensured with reduced mass and lower stress on foundations compared with solid piers. Failure of hollow columns is typically affected by premature buckling of reinforcing bars and concrete cover spalling. At present, no guidelines are available for the design of their upgrade, and few research investigations can be found on hollow columns strengthened by using fiber-reinforced polymer (FRP) materials. This paper discusses an experimental program carried out on purely compressed RC hollow columns externally wrapped with glass-fiber-reinforced polymer (GFRP). Three specimens were tested: one specimen was unstrengthened and used as the benchmark; the other two specimens were GFRP-wrapped with different confining reinforcement ratios. Each specimen was designed according to dated codes (i.e., prior to 1970) accounting only for gravity loads. In particular, steel longitudinal bars cross section and steel tie-spacing were de...
- 1 February 2011
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 15 (1) , 112-123
Structural Evaluation of Full-Scale FRP-Confined Reinforced Concrete Columns
The external confinement of RC columns by means of externally bonded fiber-reinforced polymer (FRP) laminates is a well established technique for strengthening and retrofitting purposes. This paper presents a pilot research that includes laboratory testing of full-scale square and rectangular RC columns externally confined with glass and basalt-glass FRP laminates and subjected to pure axial load. Specimens that are representative of full-scale building columns were designed according to a dated American Concrete Institute (ACI) 318 code (i.e., prior to 1970) for gravity loads only. The study was conducted to investigate how the external confinement affects peak axial strength and deformation of a prismatic RC column. The results showed that the FRP confinement increases concrete axial strength, but it is more effective in enhancing concrete strain capacity. The discussion of the results includes a comparison with the values obtained using existing constitutive models.
- 1 February 2011
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 15 (1) , 112-123
Structural Evaluation of Full-Scale FRP-Confined Reinforced Concrete Columns
The external confinement of RC columns by means of externally bonded fiber-reinforced polymer (FRP) laminates is a well established technique for strengthening and retrofitting purposes. This paper presents a pilot research that includes laboratory testing of full-scale square and rectangular RC columns externally confined with glass and basalt-glass FRP laminates and subjected to pure axial load. Specimens that are representative of full-scale building columns were designed according to a dated American Concrete Institute (ACI) 318 code (i.e., prior to 1970) for gravity loads only. The study was conducted to investigate how the external confinement affects peak axial strength and deformation of a prismatic RC column. The results showed that the FRP confinement increases concrete axial strength, but it is more effective in enhancing concrete strain capacity. The discussion of the results includes a comparison with the values obtained using existing constitutive models.
- 1 December 2010
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 136 (12) , 1483-1496
Comparative Analysis on the Seismic Behavior of Combined RC-Masonry Buildings
Since the early 20th century combined RC-masonry buildings have become more common in European, Mediterranean, and Southern America countries. Despite the diffusion of this combined building typology, the international guidelines have not followed building transformation evolutions and, in particular, for combined RC-masonry buildings, nowadays, international guidelines are not exhaustive to deal with specific issues of this building typology. Although there is a well-established background focused on the nonlinear analysis of masonry structures and RC frames, the knowledge of numerical and experimental criteria for the study of interaction effects in combined RC-masonry buildings is limited. In this paper, nonlinear static analyses (pushover analyses) on three-dimensional combined RC-masonry buildings have been performed to obtain capacity curves of single-resistant systems and of the whole building. The results confirm the code guidelines for the design of new combined RC-masonry buildings and provide interesting insights about the seismic behavior of combined RC-masonry buildings obtained from the rehabilitation of original masonry structures.
- 1 December 2010
- Published by American Society of Civil Engineers (ASCE) in Journal of Structural Engineering
- Vol. 136 (12) , 1483-1496
Comparative Analysis on the Seismic Behavior of Combined RC-Masonry Buildings
Since the early 20th century combined RC-masonry buildings have become more common in European, Mediterranean, and Southern America countries. Despite the diffusion of this combined building typology, the international guidelines have not followed building transformation evolutions and, in particular, for combined RC-masonry buildings, nowadays, international guidelines are not exhaustive to deal with specific issues of this building typology. Although there is a well-established background focused on the nonlinear analysis of masonry structures and RC frames, the knowledge of numerical and experimental criteria for the study of interaction effects in combined RC-masonry buildings is limited. In this paper, nonlinear static analyses (pushover analyses) on three-dimensional combined RC-masonry buildings have been performed to obtain capacity curves of single-resistant systems and of the whole building. The results confirm the code guidelines for the design of new combined RC-masonry buildings and provide interesting insights about the seismic behavior of combined RC-masonry buildings obtained from the rehabilitation of original masonry structures.
- 1 December 2008
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 12 (6) , 643-649
Assessment of Design Formulas for In-Plane FRP Strengthening of Masonry Walls
Masonry structures have demonstrated their seismic vulnerability during recent world seismic events. This paper investigates in-plane seismic performance of unreinforced masonry (URM) walls before and after they are retrofit using fiber-reinforced polymer (FRP) materials. An assessment of available design formulas for evaluating both the in-plane performance of URM walls and the contribution of FRP strengthening systems was performed. Walls with two configurations of the FRP reinforcement have been analyzed: one based on FRP strips installed parallel to the mortar joints, the other characterized by FRP strips arranged along the diagonals of the wall. Based on shear–compression tests carried out on FRP-strengthened masonry walls available in the literature, a comparison between theoretical and experimental data is performed. A discussion about the FRP strains at failure of the walls is provided and values of effective FRP strains to be used for design purposes are proposed.
- 1 December 2008
- Published by American Society of Civil Engineers (ASCE) in Journal of Composites for Construction
- Vol. 12 (6) , 643-649
Assessment of Design Formulas for In-Plane FRP Strengthening of Masonry Walls
Masonry structures have demonstrated their seismic vulnerability during recent world seismic events. This paper investigates in-plane seismic performance of unreinforced masonry (URM) walls before and after they are retrofit using fiber-reinforced polymer (FRP) materials. An assessment of available design formulas for evaluating both the in-plane performance of URM walls and the contribution of FRP strengthening systems was performed. Walls with two configurations of the FRP reinforcement have been analyzed: one based on FRP strips installed parallel to the mortar joints, the other characterized by FRP strips arranged along the diagonals of the wall. Based on shear–compression tests carried out on FRP-strengthened masonry walls available in the literature, a comparison between theoretical and experimental data is performed. A discussion about the FRP strains at failure of the walls is provided and values of effective FRP strains to be used for design purposes are proposed.