Marcelo Novelino Simão
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Marcelo Novelino Simão has a total of 72 co-authors. Here are the top co-authors by number of shared publications:
- Marcello Henrique Nogueira-Barbosa
Department of Medical Imaging, Hematology and Clinical Oncology, Ribeirão Preto Medical School, University of São Paulo (USP), Ribeirão Preto, Brazil
10 shared publications - Mateus de Andrade Hernandes
Universidade de São Paulo, Brazil
3 shared publications - Felipe Bortoloni Pires Correa
Universidade de São Paulo, Brazil
2 shared publications - Gabriel Brito-Barbosa
Universidade de São Paulo, Brazil
2 shared publications - Leonor Garbin Savarese
Department of Medical Imaging, Hematology and Clinical Oncology, Preto Medical School, University of Sao Paulo, Ribeirão Preto, Brazil
2 shared publications - Paulo Moraes Agnollitto
Universidade de São Paulo, Brazil
2 shared publications
Latest Publications
- 3 June 2026
- Published by Springer Nature in Skeletal Radiology
- Vol. 55 (9) , 1-2
Comment on “Modic changes and their role in vertebrogenic back pain: a literature review”
- 3 June 2026
- Published by Springer Nature in Skeletal Radiology
- Vol. 55 (9) , 1-2
Comment on “Modic changes and their role in vertebrogenic back pain: a literature review”
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Coluna/Columna
- Vol. 24 (1) , e292286
FLUID-SENSITIVE SEQUENCES MODIFY THE MODIC CLASSIFICATION IN MRI
Objective: To evaluate whether the magnetic resonance imaging (MRI) acquisition with the Dixon fat suppression technique alters the detection of signal abnormalities in the subchondral bone of the vertebral endplates in the lumbar spine. Methods: retrospective study include patients who underwent lumbar spine MRI with acquisition of T1- and T2-weighted fast spin echo sequences (routine protocol) and the multipoint Dixon sequence with T2 weighting and fat suppression. Two radiologists qualitatively classified Modic-type changes (absent, Modic I, Modic II, and Modic III) independently and blindly. When the subchondral signal abnormality was identified, each radiologist measured the maximum depth in relation to the vertebral plateau. The radiologists’ assessments were used to analyze interobserver agreement and one of the radiologists carried out a second analysis of the exams, enabling intra-observer assessment. Results: The results showed a significant increase in the detection of the edema pattern (Modic I) in qualitative and quantitative analyzes when using the Dixon technique, in comparison to the routine sequences, with an increase in the prevalence and extent of involvement by the bone edema pattern. There was no significant difference in the detection of the adipose replacement pattern (Modic II) between the two techniques. There was moderate to substantial intra-observer correlation for the traditional protocol and substantial to high agreement for the analysis of the Dixon technique images. Conclusions: The Dixon technique showed superiority in the detection of Modic I in relation to the traditional protocol, and allowed the detection, on average, of greater depth of involvement of subchondral bone changes. There was good intra-observer and inter-observer reproducibility in identifying Modic abnormalities. Evidence level III, comparative retrospective study.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Coluna/Columna
- Vol. 24 (1) , e292286
Open AccessFLUID-SENSITIVE SEQUENCES MODIFY THE MODIC CLASSIFICATION IN MRI
Objective: To evaluate whether the magnetic resonance imaging (MRI) acquisition with the Dixon fat suppression technique alters the detection of signal abnormalities in the subchondral bone of the vertebral endplates in the lumbar spine. Methods: retrospective study include patients who underwent lumbar spine MRI with acquisition of T1- and T2-weighted fast spin echo sequences (routine protocol) and the multipoint Dixon sequence with T2 weighting and fat suppression. Two radiologists qualitatively classified Modic-type changes (absent, Modic I, Modic II, and Modic III) independently and blindly. When the subchondral signal abnormality was identified, each radiologist measured the maximum depth in relation to the vertebral plateau. The radiologists’ assessments were used to analyze interobserver agreement and one of the radiologists carried out a second analysis of the exams, enabling intra-observer assessment. Results: The results showed a significant increase in the detection of the edema pattern (Modic I) in qualitative and quantitative analyzes when using the Dixon technique, in comparison to the routine sequences, with an increase in the prevalence and extent of involvement by the bone edema pattern. There was no significant difference in the detection of the adipose replacement pattern (Modic II) between the two techniques. There was moderate to substantial intra-observer correlation for the traditional protocol and substantial to high agreement for the analysis of the Dixon technique images. Conclusions: The Dixon technique showed superiority in the detection of Modic I in relation to the traditional protocol, and allowed the detection, on average, of greater depth of involvement of subchondral bone changes. There was good intra-observer and inter-observer reproducibility in identifying Modic abnormalities. Evidence level III, comparative retrospective study.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 58
Melhorando a caracterização osteoarticular na ressonância magnética: o papel das sequências que simulam o contraste tecidual da tomografia computadorizada
Aumentar o contraste tecidual nas imagens obtidas com a ressonância magnética para avaliação óssea tem sido o objetivo de vários estudos recentes e diversas técnicas têm sido propostas para este fim, incluindo sequências com tempo de eco ultracurto, tempo de eco zero, além de sequências com eco de gradiente, em variadas formas de aquisição. Neste artigo trazemos o uso da sequência FRACTURE (acrônimo do inglês para fast field echo resembling a CT using restricted echo spacing), que passamos a utilizar rotineiramente no nosso serviço. Esta técnica se baseia na aquisição de sequência gradiente eco com diferentes tempos de eco e pós-processamento específico. As sequências gradiente eco são amplamente disponíveis nos equipamentos de ressonância magnética, o que representa uma vantagem para esta sequência. Contudo, por ser mais suscetível a artefatos metálicos, é limitada em pacientes com implantes e dispositivos metálicos. O objetivo deste artigo é ilustrar o uso da sequência FRACTURE em diferentes contextos, incluindo, entre outros, infecção osteoarticular, artropatia inflamatória, tumores ósseos, fraturas e doenças de deposição de cristais.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 58
Open AccessMelhorando a caracterização osteoarticular na ressonância magnética: o papel das sequências que simulam o contraste tecidual da tomografia computadorizada
Aumentar o contraste tecidual nas imagens obtidas com a ressonância magnética para avaliação óssea tem sido o objetivo de vários estudos recentes e diversas técnicas têm sido propostas para este fim, incluindo sequências com tempo de eco ultracurto, tempo de eco zero, além de sequências com eco de gradiente, em variadas formas de aquisição. Neste artigo trazemos o uso da sequência FRACTURE (acrônimo do inglês para fast field echo resembling a CT using restricted echo spacing), que passamos a utilizar rotineiramente no nosso serviço. Esta técnica se baseia na aquisição de sequência gradiente eco com diferentes tempos de eco e pós-processamento específico. As sequências gradiente eco são amplamente disponíveis nos equipamentos de ressonância magnética, o que representa uma vantagem para esta sequência. Contudo, por ser mais suscetível a artefatos metálicos, é limitada em pacientes com implantes e dispositivos metálicos. O objetivo deste artigo é ilustrar o uso da sequência FRACTURE em diferentes contextos, incluindo, entre outros, infecção osteoarticular, artropatia inflamatória, tumores ósseos, fraturas e doenças de deposição de cristais.
- Open Access
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 58
Improving osteoarticular characterization in magnetic resonance imaging: the role of simulated computed tomography sequences
Increasing tissue contrast for bone assessment on magnetic resonance imaging has been the aim of several recent studies, and various techniques have been proposed for that purpose, including ultrashort echo time sequences, zero echo time sequences, and gradient echo sequences in various acquisition forms. In this article, we discuss the fast field echo resembling a computed tomography using restricted echo-spacing (FRACTURE) sequence, which we have started to use routinely in our practice. The FRACTURE sequences are based on the acquisition of gradient echo sequences with different echo times and specific postprocessing. Gradient echo sequences are widely available on magnetic resonance imaging scanners, which is an advantage for the use of a FRACTURE sequence. However, being more susceptible to metal artifacts, a FRACTURE sequence is of limited utility in patients with metallic implants or medical devices. The aim of this article is to illustrate the use of FRACTURE sequences in various contexts, including osteoarticular infection, inflammatory arthropathy, bone tumors, fractures, and crystal deposition diseases.
- 1 January 2025
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 58
Open AccessImproving osteoarticular characterization in magnetic resonance imaging: the role of simulated computed tomography sequences
Increasing tissue contrast for bone assessment on magnetic resonance imaging has been the aim of several recent studies, and various techniques have been proposed for that purpose, including ultrashort echo time sequences, zero echo time sequences, and gradient echo sequences in various acquisition forms. In this article, we discuss the fast field echo resembling a computed tomography using restricted echo-spacing (FRACTURE) sequence, which we have started to use routinely in our practice. The FRACTURE sequences are based on the acquisition of gradient echo sequences with different echo times and specific postprocessing. Gradient echo sequences are widely available on magnetic resonance imaging scanners, which is an advantage for the use of a FRACTURE sequence. However, being more susceptible to metal artifacts, a FRACTURE sequence is of limited utility in patients with metallic implants or medical devices. The aim of this article is to illustrate the use of FRACTURE sequences in various contexts, including osteoarticular infection, inflammatory arthropathy, bone tumors, fractures, and crystal deposition diseases.
- Open Access
- 1 October 2021
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 54 (5) , 303-310
Magnetic resonance imaging evaluation of common peroneal nerve injury in acute and subacute posterolateral corner lesion: a retrospective study
Objective: To evaluate qualitative and quantitative magnetic resonance imaging (MRI) criteria for injury of the common peroneal nerve (CPN) in patients with acute or subacute injuries in the posterolateral corner (PLC) of the knee, as well as to evaluate the reproducibility of MRI evaluation of CPN alterations. Materials and Methods: This was a retrospective study of 38 consecutive patients submitted to MRI and diagnosed with acute or subacute injury to the PLC of the knee (patient group) and 38 patients with normal MRI results (control group). Two musculoskeletal radiologists (designated radiologist A and radiologist B, respectively) evaluated the images. Nerve injury was classified as neurapraxia, axonotmesis, or neurotmesis. Signal strength was measured at the CPN, the tibial nerve (TN), and a superficial vein (SV). The CPN/TN and CPN/SV signal ratios were calculated. The status of each PLC structure, including the popliteal tendon, arcuate ligament, lateral collateral ligament, and biceps tendon, was classified as normal, partially torn, or completely torn, as was that of the cruciate ligaments. For the semiquantitative analysis of interobserver agreement, the kappa statistic was calculated, whereas a receiver operating characteristic (ROC) curve was used for the quantitative analysis. Results: In the patient group, radiologist A found CPN abnormalities in 15 cases (39.4%)-neurapraxia in eight and axonotmesis in seven-whereas radiologist B found CPN abnormalities in 14 (36.8%)-neurapraxia in nine and axonotmesis in five. The kappa statistic showed excellent interobserver agreement. In the control group, the CPN/TN signal ratio ranged from 0.63 to 1.1 and the CPN/SV signal ratio ranged from 0.16 to 0.41, compared with 1.30-4.02 and 0.27-1.08, respectively, in the patient group. The ROC curve analysis demonstrated that the CPN/TN signal ratio at a cutoff value of 1.39 had high (93.3%) specificity for the identification of nerve damage, compared with 81.3% for the CPN/SV signal ratio at a cutoff value of 0.41. Conclusion: CPN alterations are common in patients with PLC injury detected on MRI, and the level of interobserver agreement for such alterations was excellent. Calculating the CPN/TN and CPN/SV signal ratios may increase diagnostic confidence. We recommend systematic analysis of the CPN in cases of PLC injury.
- 1 October 2021
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 54 (5) , 303-310
Open AccessMagnetic resonance imaging evaluation of common peroneal nerve injury in acute and subacute posterolateral corner lesion: a retrospective study
Objective: To evaluate qualitative and quantitative magnetic resonance imaging (MRI) criteria for injury of the common peroneal nerve (CPN) in patients with acute or subacute injuries in the posterolateral corner (PLC) of the knee, as well as to evaluate the reproducibility of MRI evaluation of CPN alterations. Materials and Methods: This was a retrospective study of 38 consecutive patients submitted to MRI and diagnosed with acute or subacute injury to the PLC of the knee (patient group) and 38 patients with normal MRI results (control group). Two musculoskeletal radiologists (designated radiologist A and radiologist B, respectively) evaluated the images. Nerve injury was classified as neurapraxia, axonotmesis, or neurotmesis. Signal strength was measured at the CPN, the tibial nerve (TN), and a superficial vein (SV). The CPN/TN and CPN/SV signal ratios were calculated. The status of each PLC structure, including the popliteal tendon, arcuate ligament, lateral collateral ligament, and biceps tendon, was classified as normal, partially torn, or completely torn, as was that of the cruciate ligaments. For the semiquantitative analysis of interobserver agreement, the kappa statistic was calculated, whereas a receiver operating characteristic (ROC) curve was used for the quantitative analysis. Results: In the patient group, radiologist A found CPN abnormalities in 15 cases (39.4%)-neurapraxia in eight and axonotmesis in seven-whereas radiologist B found CPN abnormalities in 14 (36.8%)-neurapraxia in nine and axonotmesis in five. The kappa statistic showed excellent interobserver agreement. In the control group, the CPN/TN signal ratio ranged from 0.63 to 1.1 and the CPN/SV signal ratio ranged from 0.16 to 0.41, compared with 1.30-4.02 and 0.27-1.08, respectively, in the patient group. The ROC curve analysis demonstrated that the CPN/TN signal ratio at a cutoff value of 1.39 had high (93.3%) specificity for the identification of nerve damage, compared with 81.3% for the CPN/SV signal ratio at a cutoff value of 0.41. Conclusion: CPN alterations are common in patients with PLC injury detected on MRI, and the level of interobserver agreement for such alterations was excellent. Calculating the CPN/TN and CPN/SV signal ratios may increase diagnostic confidence. We recommend systematic analysis of the CPN in cases of PLC injury.
- Open Access
- 1 June 2021
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 54 (3) , 148-154
Evaluation of variations of the glenoid attachment of the inferior glenohumeral ligament by magnetic resonance arthrography
Objective: To evaluate the anatomical variations of the attachment of the inferior glenohumeral ligament (IGHL) to the anterior glenoid rim. Materials and Methods: This was a retrospective review of 93 magnetic resonance arthrography examinations of the shoulder. Two radiologists, who were blinded to the patient data and were working independently, read the examinations. Interobserver and intraobserver agreement were evaluated. The pattern of IGHL glenoid attachment and its position on the anterior glenoid rim were recorded. Results: In 50 examinations (53.8%), the glenoid attachment was classified as type I (originating from the labrum), whereas it was classified as type II (originating from the glenoid neck) in 43 (46.2%). The IGHL emerged at the 4 o’clock position in 58 cases (62.4%), at the 3 o’clock position in 14 (15.0%), and at the 5 o’clock position in 21 (22.6%). The rates of interobserver and intraobserver agreement were excellent. Conclusion: Although type I IGHL glenoid attachment is more common, we found a high prevalence of the type II variation. The IGHL emerged between the 3 o’clock and 5 o’clock positions, most commonly at the 4 o’clock position.
- 1 June 2021
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 54 (3) , 148-154
Open AccessEvaluation of variations of the glenoid attachment of the inferior glenohumeral ligament by magnetic resonance arthrography
Objective: To evaluate the anatomical variations of the attachment of the inferior glenohumeral ligament (IGHL) to the anterior glenoid rim. Materials and Methods: This was a retrospective review of 93 magnetic resonance arthrography examinations of the shoulder. Two radiologists, who were blinded to the patient data and were working independently, read the examinations. Interobserver and intraobserver agreement were evaluated. The pattern of IGHL glenoid attachment and its position on the anterior glenoid rim were recorded. Results: In 50 examinations (53.8%), the glenoid attachment was classified as type I (originating from the labrum), whereas it was classified as type II (originating from the glenoid neck) in 43 (46.2%). The IGHL emerged at the 4 o’clock position in 58 cases (62.4%), at the 3 o’clock position in 14 (15.0%), and at the 5 o’clock position in 21 (22.6%). The rates of interobserver and intraobserver agreement were excellent. Conclusion: Although type I IGHL glenoid attachment is more common, we found a high prevalence of the type II variation. The IGHL emerged between the 3 o’clock and 5 o’clock positions, most commonly at the 4 o’clock position.
- Open Access
- 1 February 2021
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 54 (1)
Patellar chondropathy: a brief overview of its history and prevalence
Chondromalacia is a term of Greek origin, formed from a combination of the words khóndros (cartilage) and malakos (softened). It is widely used in the medical field in general and in a large number of scientific articles as a synonym for chondral lesion. However, it can be considered more of a figure of speech of the metonymy type, in which a thing or concept is referred to by the name of something closely associated with that thing or concept. In this case, it represents a whole spectrum of chondral changes, given that chondral lesions encompass much more than softening. As demonstrated by Outerbridge(1), softening is only the initial stage of the chondral injury process. Therefore, terms such as chondropathy and chondral lesion better represent the spectrum of chondral involvement, as mentioned in the article by Krieger et al.(2), published in the previous issue of Radiologia Brasileira.
- 1 February 2021
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 54 (1)
Open AccessPatellar chondropathy: a brief overview of its history and prevalence
Chondromalacia is a term of Greek origin, formed from a combination of the words khóndros (cartilage) and malakos (softened). It is widely used in the medical field in general and in a large number of scientific articles as a synonym for chondral lesion. However, it can be considered more of a figure of speech of the metonymy type, in which a thing or concept is referred to by the name of something closely associated with that thing or concept. In this case, it represents a whole spectrum of chondral changes, given that chondral lesions encompass much more than softening. As demonstrated by Outerbridge(1), softening is only the initial stage of the chondral injury process. Therefore, terms such as chondropathy and chondral lesion better represent the spectrum of chondral involvement, as mentioned in the article by Krieger et al.(2), published in the previous issue of Radiologia Brasileira.
- 1 March 2018
- Published by Elsevier in Journal Of Neuroradiology
- Vol. 45 (2) , 147-151
Assessment of the cervical spine denticulate ligament using MRI volumetric sequence: Comparison between 1.5 Tesla and 3.0 Tesla
- 1 March 2018
- Published by Elsevier in Journal Of Neuroradiology
- Vol. 45 (2) , 147-151
Assessment of the cervical spine denticulate ligament using MRI volumetric sequence: Comparison between 1.5 Tesla and 3.0 Tesla
- Open Access
- 1 August 2016
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 49 (4) , 220-224
Magnetic resonance imaging evaluation of meniscoid superior labrum: normal variant or superior labral tear
Objective: The objective of this study was to determine the incidence of a "meniscoid" superior labrum. Materials and Methods: This was a retrospective analysis of 582 magnetic resonance imaging examinations of shoulders. Of those 582 examinations, 110 were excluded, for a variety of reasons, and the final analysis therefore included 472 cases. Consensus readings were performed by three musculoskeletal radiologists using specific criteria to diagnose meniscoid labra. Results: A meniscoid superior labrum was identified in 48 (10.2%) of the 472 cases evaluated. Arthroscopic proof was available in 21 cases (43.8%). In 10 (47.6%) of those 21 cases, the operative report did not include the mention a superior labral tear, thus suggesting the presence of a meniscoid labrum. In only one of those cases were there specific comments about a mobile superior labrum (i.e., meniscoid labrum). In the remaining 11 (52.4%), surgical correlation demonstrated superior labral tears. Conclusion: A meniscoid superior labrum is not an infrequent finding. Depending upon assumptions and the requirement of surgical proof, the prevalence of a meniscoid superior labrum in this study was between 2.1% (surgically proven) and 4.8% (projected). However, superior labral tears are just as common and are often confused with meniscoid labra.
- 1 August 2016
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 49 (4) , 220-224
Open AccessMagnetic resonance imaging evaluation of meniscoid superior labrum: normal variant or superior labral tear
Objective: The objective of this study was to determine the incidence of a "meniscoid" superior labrum. Materials and Methods: This was a retrospective analysis of 582 magnetic resonance imaging examinations of shoulders. Of those 582 examinations, 110 were excluded, for a variety of reasons, and the final analysis therefore included 472 cases. Consensus readings were performed by three musculoskeletal radiologists using specific criteria to diagnose meniscoid labra. Results: A meniscoid superior labrum was identified in 48 (10.2%) of the 472 cases evaluated. Arthroscopic proof was available in 21 cases (43.8%). In 10 (47.6%) of those 21 cases, the operative report did not include the mention a superior labral tear, thus suggesting the presence of a meniscoid labrum. In only one of those cases were there specific comments about a mobile superior labrum (i.e., meniscoid labrum). In the remaining 11 (52.4%), surgical correlation demonstrated superior labral tears. Conclusion: A meniscoid superior labrum is not an infrequent finding. Depending upon assumptions and the requirement of surgical proof, the prevalence of a meniscoid superior labrum in this study was between 2.1% (surgically proven) and 4.8% (projected). However, superior labral tears are just as common and are often confused with meniscoid labra.
- Open Access
- 1 April 2014
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 47 (2)
Carpal boss: a sonographic view
Dorsal wrist mass may originate from soft tissues and in such cases the differential diagnoses include ganglion cyst, soft tissue calcifications, tendon sheath giant cell tumor, lipoma and neuroma, amongst other possible small tumors. However, the mass may result from bone changes including small tumors such as osteochondromas, osteomas, degenerative changes with marginal osteophytes and presence of an accessory ossicle such as the os styloideum(1,2).
- 1 April 2014
- Published by FapUNIFESP (SciELO) in Radiologia Brasileira
- Vol. 47 (2)
Open AccessCarpal boss: a sonographic view
Dorsal wrist mass may originate from soft tissues and in such cases the differential diagnoses include ganglion cyst, soft tissue calcifications, tendon sheath giant cell tumor, lipoma and neuroma, amongst other possible small tumors. However, the mass may result from bone changes including small tumors such as osteochondromas, osteomas, degenerative changes with marginal osteophytes and presence of an accessory ossicle such as the os styloideum(1,2).