MHMateus de Andrade Hernandes

Mateus de Andrade Hernandes

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Mateus de Andrade Hernandes has a total of 15 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Beyond Chordoma: A Comprehensive Review of Sacral Lesions

    by Leonor Garbin Savarese, Nicolas Papalexis, Mateus de Andrade Hernandes, Giancarlo Facchini, Marco Miceli, Marcello Henrique Nogueira-Barbosa

    The sacrum is a common site for a wide range of pathological processes, including benign and malignant tumors as well as non-neoplastic conditions. Accurate diagnosis of sacral lesions remains challenging due to overlapping imaging features and the anatomical complexity of the region. This review provides a comprehensive overview of sacral lesions, with emphasis on imaging characteristics, diagnostic challenges, and clinical implications. Key imaging findings are highlighted to help narrow the differential diagnosis. While certain imaging patterns may suggest specific etiologies, image-guided biopsy is often necessary for definitive diagnosis. Familiarity with the spectrum of sacral pathologies is essential for radiologists to effectively contribute to diagnosis, patient management, and multidisciplinary care.

  • Open Access

    Melhorando a caracterização osteoarticular na ressonância magnética: o papel das sequências que simulam o contraste tecidual da tomografia computadorizada

    by Gabriel Brito-Barbosa, Felipe Bortoloni Pires Correa, Leonor Garbin Savarese, Mateus Andrade Hernandes, Paulo Moraes Agnollitto, Marcelo Novelino Simão, Marcello Henrique Nogueira-Barbosa

    Aumentar o contraste tecidual nas imagens obtidas com a ressonância magnética para avaliação óssea tem sido o objetivo de vários estudos recentes e diversas técnicas têm sido propostas para este fim, incluindo sequências com tempo de eco ultracurto, tempo de eco zero, além de sequências com eco de gradiente, em variadas formas de aquisição. Neste artigo trazemos o uso da sequência FRACTURE (acrônimo do inglês para fast field echo resembling a CT using restricted echo spacing), que passamos a utilizar rotineiramente no nosso serviço. Esta técnica se baseia na aquisição de sequência gradiente eco com diferentes tempos de eco e pós-processamento específico. As sequências gradiente eco são amplamente disponíveis nos equipamentos de ressonância magnética, o que representa uma vantagem para esta sequência. Contudo, por ser mais suscetível a artefatos metálicos, é limitada em pacientes com implantes e dispositivos metálicos. O objetivo deste artigo é ilustrar o uso da sequência FRACTURE em diferentes contextos, incluindo, entre outros, infecção osteoarticular, artropatia inflamatória, tumores ósseos, fraturas e doenças de deposição de cristais.

  • Open Access

    Improving osteoarticular characterization in magnetic resonance imaging: the role of simulated computed tomography sequences

    by Gabriel Brito-Barbosa, Felipe Bortoloni Pires Correa, Leonor Garbin Savarese, Mateus Andrade Hernandes, Paulo Moraes Agnollitto, Marcelo Novelino Simão, Marcello Henrique Nogueira-Barbosa

    Increasing tissue contrast for bone assessment on magnetic resonance imaging has been the aim of several recent studies, and various techniques have been proposed for that purpose, including ultrashort echo time sequences, zero echo time sequences, and gradient echo sequences in various acquisition forms. In this article, we discuss the fast field echo resembling a computed tomography using restricted echo-spacing (FRACTURE) sequence, which we have started to use routinely in our practice. The FRACTURE sequences are based on the acquisition of gradient echo sequences with different echo times and specific postprocessing. Gradient echo sequences are widely available on magnetic resonance imaging scanners, which is an advantage for the use of a FRACTURE sequence. However, being more susceptible to metal artifacts, a FRACTURE sequence is of limited utility in patients with metallic implants or medical devices. The aim of this article is to illustrate the use of FRACTURE sequences in various contexts, including osteoarticular infection, inflammatory arthropathy, bone tumors, fractures, and crystal deposition diseases.

  • Open Access

    Evaluation of variations of the glenoid attachment of the inferior glenohumeral ligament by magnetic resonance arthrography

    by Marcelo Novelino Simão, Maximilian Jokiti Kobayashi, Matheus de Andrade Hernandes, Marcello Henrique Nogueira-Barbosa

    Objective: To evaluate the anatomical variations of the attachment of the inferior glenohumeral ligament (IGHL) to the anterior glenoid rim. Materials and Methods: This was a retrospective review of 93 magnetic resonance arthrography examinations of the shoulder. Two radiologists, who were blinded to the patient data and were working independently, read the examinations. Interobserver and intraobserver agreement were evaluated. The pattern of IGHL glenoid attachment and its position on the anterior glenoid rim were recorded. Results: In 50 examinations (53.8%), the glenoid attachment was classified as type I (originating from the labrum), whereas it was classified as type II (originating from the glenoid neck) in 43 (46.2%). The IGHL emerged at the 4 o’clock position in 58 cases (62.4%), at the 3 o’clock position in 14 (15.0%), and at the 5 o’clock position in 21 (22.6%). The rates of interobserver and intraobserver agreement were excellent. Conclusion: Although type I IGHL glenoid attachment is more common, we found a high prevalence of the type II variation. The IGHL emerged between the 3 o’clock and 5 o’clock positions, most commonly at the 4 o’clock position.


  • Open Access

    Manual versus semiautomatic segmentation of soft-tissue sarcomas on magnetic resonance imaging: evaluation of similarity and comparison of segmentation times

    by Fernando Carrasco Ferreira Dionisio, Larissa Santos Oliveira, Mateus de Andrade Hernandes, Edgard Eduard Engel, Paulo Mazzoncini de Azevedo-Marques, Marcello Henrique Nogueira-Barbosa

    Objective: To evaluate the degree of similarity between manual and semiautomatic segmentation of soft-tissue sarcomas on magnetic resonance imaging (MRI). Materials and Methods: This was a retrospective study of 15 MRI examinations of patients with histopathologically confirmed soft-tissue sarcomas acquired before therapeutic intervention. Manual and semiautomatic segmentations were performed by three radiologists, working independently, using the software 3D Slicer. The Dice similarity coefficient (DSC) and the Hausdorff distance were calculated in order to evaluate the similarity between manual and semiautomatic segmentation. To compare the two modalities in terms of the tumor volumes obtained, we also calculated descriptive statistics and intraclass correlation coefficients (ICCs). Results: In the comparison between manual and semiautomatic segmentation, the DSC values ranged from 0.871 to 0.973. The comparison of the volumes segmented by the two modalities resulted in ICCs between 0.9927 and 0.9990. The DSC values ranged from 0.849 to 0.979 for intraobserver variability and from 0.741 to 0.972 for interobserver variability. There was no significant difference between the semiautomatic and manual modalities in terms of the segmentation times (p > 0.05). Conclusion: There appears to be a high degree of similarity between manual and semiautomatic segmentation, with no significant difference between the two modalities in terms of the time required for segmentation.


  • Open Access

    Manual and semiautomatic segmentation of bone sarcomas on MRI have high similarity

    by F.C.F. Dionísio, L.S. Oliveira, M.A. Hernandes, E.E. Engel, R.M. Rangayyan, P.M. Azevedo-Marques, M.H. Nogueira-Barbosa

    The aims of this study were to evaluate the intra- and interobserver reproducibility of manual segmentation of bone sarcomas in magnetic resonance imaging (MRI) studies and to compare manual and semiautomatic segmentation methods. This retrospective study included twelve osteosarcoma and eight Ewing sarcoma MRI studies performed prior to any therapeutic intervention. All cases were histopathologically confirmed. Three radiologists used 3D-Slicer software to perform manual segmentation of bone sarcomas in a blinded and independent manner. One radiologist segmented manually and also performed semiautomatic segmentation with the GrowCut tool. Segmentation exercises were timed for comparison. The dice similarity coefficient (DSC) and Hausdorff distance (HD) were used to evaluate similarity between the segmentation results and further statistical analyses were performed to compare DSC, HD, and volumetric results. Manual segmentation was reproducible with intraobserver DSC varying from 0.83 to 0.97 and HD from 3.37 to 28.73 mm. Interobserver DSC of manual segmentation showed variation from 0.73 to 0.97 and HD from 3.93 to 33.40 mm. Semiautomatic segmentation compared to manual segmentation resulted in DSCs of 0.71-0.96 and HDs of 5.38-31.54 mm. Semiautomatic segmentation required significantly less time compared to manual segmentation (P value ≤0.05). Among all situations compared, tumor volumetry did not show significant statistical differences (P value >0.05). We found excellent intra- and interobserver agreement for manual segmentation of osteosarcoma and Ewing sarcoma. There was high similarity between manual and semiautomatic segmentation, with a significant reduction of segmentation time using the semiautomatic method.