Mireille Garreau
Research Subjects
Mireille Garreau has a total of 82 co-authors. Here are the top co-authors by number of shared publications:
- Antoine Simon
LTSI, Universite de Rennes 1, Bât. 22, Campus de Beaulieu, Rennes, 35065, FRANCE
5 shared publications - Alfredo I. Hernandez
Univ Rennes, Inserm, LTSI - UMR 1099, Rennes, F-35000, France
2 shared publications - Angélica Atehortúa
Barcelona Institute for Global Health (ISGlobal), Barcelona, Spain
2 shared publications Christophe Leclercq
INSERM, Rennes, France
2 shared publications- Dominique Boulmier
Cardiologie, CHU de Rennes, F-35033 Rennes, Rennes, France
2 shared publications - Erwan Donal
University of Rennes, CHU Rennes, Inserm, LTSI – UMR 1099 , F-35000 Rennes
2 shared publications
Latest Publications
- Open Access
- 16 October 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (20) , 205011
Towards artificial intelligence based preoperative dosimetry for liver 90 Y selective internal radiation therapy
Objective. Selective internal radiation therapy delivers Y‐90 microspheres through the hepatic arterial system to achieve tumoricidal absorbed dose while limiting normal‐tissue irradiation. Current pre‐treatment dosimetry requires angiography and 99 mTc‐MAA imaging, resulting in an invasive and resource‐intensive workflow. This study evaluates the feasibility of estimating post‐therapy Y‐90 dose distribution directly from diagnostic multiphasic CT using an automated deep‐learning pipeline, without requiring angiography or surrogate‐particle imaging. Approach. In 152 treatments from the multicenter PROACTIF registry, arterial‐ and portal‐phase CT, together with clinically documented perfusion territories and injected activities, were processed through automated segmentation, rigid registration, differential CT generation, and a generative model synthesizing a PET‐like Y‐90 activity map. Absorbed‐dose maps were computed using the Local Dose Deposition method, and predictive accuracy was assessed using tumor dose–volume metrics and voxelwise spatial agreement. Main results. For the best‐performing configuration, the median tumor D70 error was 23 Gy, with substantial inter‐patient variability reflecting the challenges of CT‐only dose prediction. High‐dose coverage (V200) showed a similar pattern. In contrast, spatial agreement was consistently strong, with perfused‐volume gamma passing rates around 93% and tumor‐level rates around 85%, indicating that the macro‐scale distribution of microspheres can be approximated from diagnostic CT. The full pipeline was fully automated and produced predictive dosimetry in under 30 S. Significance. Pre‐angiography CT contains exploitable information about arterial enhancement and perfusion patterns that enables feasible CT‐only prediction of Y‐90 spatial distribution. While tumor‐level absorbed‐dose metrics remain variable, the strong spatial agreement suggests potential utility as an early planning tool to support patient selection or guide catheterization strategy prior to angiography.
- 16 October 2026
- Published by IOP Publishing in Physics in Medicine & Biology
- Vol. 71 (20) , 205011
Open AccessTowards artificial intelligence based preoperative dosimetry for liver 90 Y selective internal radiation therapy
Objective. Selective internal radiation therapy delivers Y‐90 microspheres through the hepatic arterial system to achieve tumoricidal absorbed dose while limiting normal‐tissue irradiation. Current pre‐treatment dosimetry requires angiography and 99 mTc‐MAA imaging, resulting in an invasive and resource‐intensive workflow. This study evaluates the feasibility of estimating post‐therapy Y‐90 dose distribution directly from diagnostic multiphasic CT using an automated deep‐learning pipeline, without requiring angiography or surrogate‐particle imaging. Approach. In 152 treatments from the multicenter PROACTIF registry, arterial‐ and portal‐phase CT, together with clinically documented perfusion territories and injected activities, were processed through automated segmentation, rigid registration, differential CT generation, and a generative model synthesizing a PET‐like Y‐90 activity map. Absorbed‐dose maps were computed using the Local Dose Deposition method, and predictive accuracy was assessed using tumor dose–volume metrics and voxelwise spatial agreement. Main results. For the best‐performing configuration, the median tumor D70 error was 23 Gy, with substantial inter‐patient variability reflecting the challenges of CT‐only dose prediction. High‐dose coverage (V200) showed a similar pattern. In contrast, spatial agreement was consistently strong, with perfused‐volume gamma passing rates around 93% and tumor‐level rates around 85%, indicating that the macro‐scale distribution of microspheres can be approximated from diagnostic CT. The full pipeline was fully automated and produced predictive dosimetry in under 30 S. Significance. Pre‐angiography CT contains exploitable information about arterial enhancement and perfusion patterns that enables feasible CT‐only prediction of Y‐90 spatial distribution. While tumor‐level absorbed‐dose metrics remain variable, the strong spatial agreement suggests potential utility as an early planning tool to support patient selection or guide catheterization strategy prior to angiography.
- 13 October 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 242, 107841
Segmentation of cardiac infarction in delayed-enhancement MRI using probability map and transformers-based neural networks
- 13 October 2023
- Published by Elsevier in Computer Methods and Programs in Biomedicine
- Vol. 242, 107841
Segmentation of cardiac infarction in delayed-enhancement MRI using probability map and transformers-based neural networks
- Open Access
- 6 February 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (2) , 53
Desynchronization Strain Patterns and Contractility in Left Bundle Branch Block through Computer Model Simulation
Left bundle branch block (LBBB) is associated with specific septal-to-lateral wall activation patterns which are strongly influenced by the intrinsic left ventricular (LV) contractility and myocardial scar localization. The objective of this study was to propose a computational-model-based interpretation of the different patterns of LV contraction observed in the case of LBBB and preserved contractility or myocardial scarring. Two-dimensional transthoracic echocardiography was used to obtain LV volumes and deformation patterns in three patients with LBBB: (1) a patient with non-ischemic dilated cardiomyopathy, (2) a patient with antero-septal myocardial scar, and (3) a patient with lateral myocardial scar. Scar was confirmed by the distribution of late gadolinium enhancement with cardiac magnetic resonance imaging (cMRI). Model parameters were evaluated manually to reproduce patient-derived data such as strain curves obtained from echocardiographic apical views. The model was able to reproduce the specific strain patterns observed in patients. A typical septal flash with pre-ejection shortening, rebound stretch, and delayed lateral wall activation was observed in the case of non-ischemic cardiomyopathy. In the case of lateral scar, the contractility of the lateral wall was significantly impaired and septal flash was absent. In the case of septal scar, septal flash and rebound stretch were also present as previously described in the literature. Interestingly, the model was also able to simulate the specific contractile properties of the myocardium, providing an excellent localization of LV scar in ischemic patients. The model was able to simulate the electromechanical delay and specific contractility patterns observed in patients with LBBB of ischemic and non-ischemic etiology. With further improvement and validation, this technique might be a useful tool for the diagnosis and treatment planning of heart failure patients needing CRT.
- 6 February 2022
- Published by MDPI AG in Journal of Cardiovascular Development and Disease
- Vol. 9 (2) , 53
Open AccessDesynchronization Strain Patterns and Contractility in Left Bundle Branch Block through Computer Model Simulation
Left bundle branch block (LBBB) is associated with specific septal-to-lateral wall activation patterns which are strongly influenced by the intrinsic left ventricular (LV) contractility and myocardial scar localization. The objective of this study was to propose a computational-model-based interpretation of the different patterns of LV contraction observed in the case of LBBB and preserved contractility or myocardial scarring. Two-dimensional transthoracic echocardiography was used to obtain LV volumes and deformation patterns in three patients with LBBB: (1) a patient with non-ischemic dilated cardiomyopathy, (2) a patient with antero-septal myocardial scar, and (3) a patient with lateral myocardial scar. Scar was confirmed by the distribution of late gadolinium enhancement with cardiac magnetic resonance imaging (cMRI). Model parameters were evaluated manually to reproduce patient-derived data such as strain curves obtained from echocardiographic apical views. The model was able to reproduce the specific strain patterns observed in patients. A typical septal flash with pre-ejection shortening, rebound stretch, and delayed lateral wall activation was observed in the case of non-ischemic cardiomyopathy. In the case of lateral scar, the contractility of the lateral wall was significantly impaired and septal flash was absent. In the case of septal scar, septal flash and rebound stretch were also present as previously described in the literature. Interestingly, the model was also able to simulate the specific contractile properties of the myocardium, providing an excellent localization of LV scar in ischemic patients. The model was able to simulate the electromechanical delay and specific contractility patterns observed in patients with LBBB of ischemic and non-ischemic etiology. With further improvement and validation, this technique might be a useful tool for the diagnosis and treatment planning of heart failure patients needing CRT.
- 3 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (9) , 3541-3553
Left Ventricle Quantification Challenge: A Comprehensive Comparison and Evaluation of Segmentation and Regression for Mid-Ventricular Short-Axis Cardiac MR Data
Automatic quantification of the left ventricle (LV) from cardiac magnetic resonance (CMR) images plays an important role in making the diagnosis procedure efficient, reliable, and alleviating the laborious reading work for physicians. Considerable efforts have been devoted to LV quantification using different strategies that include segmentation-based (SG) methods and the recent direct regression (DR) methods. Although both SG and DR methods have obtained great success for the task, a systematic platform to benchmark them remains absent because of differences in label information during model learning. In this paper, we conducted an unbiased evaluation and comparison of cardiac LV quantification methods that were submitted to the Left Ventricle Quantification (LVQuan) challenge, which was held in conjunction with the Statistical Atlases and Computational Modeling of the Heart (STACOM) workshop at the MICCAI 2018. The challenge was targeted at the quantification of 1) areas of LV cavity and myocardium, 2) dimensions of the LV cavity, 3) regional wall thicknesses (RWT), and 4) the cardiac phase, from mid-ventricle short-axis CMR images. First, we constructed a public quantification dataset Cardiac-DIG with ground truth labels for both the myocardium mask and these quantification targets across the entire cardiac cycle. Then, the key techniques employed by each submission were described. Next, quantitative validation of these submissions were conducted with the constructed dataset. The evaluation results revealed that both SG and DR methods can offer good LV quantification performance, even though DR methods do not require densely labeled masks for supervision. Among the 12 submissions, the DR method LDAMT offered the best performance, with a mean estimation error of 301 mm 2 for the two areas, 2.15 mm for the cavity dimensions, 2.03 mm for RWTs, and a 9.5% error rate for the cardiac phase classification. Three of the SG methods also delivered comparable performances. Finally, we discussed the advantages and disadvantages of SG and DR methods, as well as the unsolved problems in automatic cardiac quantification for clinical practice applications.
- 3 September 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 25 (9) , 3541-3553
Left Ventricle Quantification Challenge: A Comprehensive Comparison and Evaluation of Segmentation and Regression for Mid-Ventricular Short-Axis Cardiac MR Data
Automatic quantification of the left ventricle (LV) from cardiac magnetic resonance (CMR) images plays an important role in making the diagnosis procedure efficient, reliable, and alleviating the laborious reading work for physicians. Considerable efforts have been devoted to LV quantification using different strategies that include segmentation-based (SG) methods and the recent direct regression (DR) methods. Although both SG and DR methods have obtained great success for the task, a systematic platform to benchmark them remains absent because of differences in label information during model learning. In this paper, we conducted an unbiased evaluation and comparison of cardiac LV quantification methods that were submitted to the Left Ventricle Quantification (LVQuan) challenge, which was held in conjunction with the Statistical Atlases and Computational Modeling of the Heart (STACOM) workshop at the MICCAI 2018. The challenge was targeted at the quantification of 1) areas of LV cavity and myocardium, 2) dimensions of the LV cavity, 3) regional wall thicknesses (RWT), and 4) the cardiac phase, from mid-ventricle short-axis CMR images. First, we constructed a public quantification dataset Cardiac-DIG with ground truth labels for both the myocardium mask and these quantification targets across the entire cardiac cycle. Then, the key techniques employed by each submission were described. Next, quantitative validation of these submissions were conducted with the constructed dataset. The evaluation results revealed that both SG and DR methods can offer good LV quantification performance, even though DR methods do not require densely labeled masks for supervision. Among the 12 submissions, the DR method LDAMT offered the best performance, with a mean estimation error of 301 mm 2 for the two areas, 2.15 mm for the cavity dimensions, 2.03 mm for RWTs, and a 9.5% error rate for the cardiac phase classification. Three of the SG methods also delivered comparable performances. Finally, we discussed the advantages and disadvantages of SG and DR methods, as well as the unsolved problems in automatic cardiac quantification for clinical practice applications.
- Open Access
- 3 September 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (9) , e0238463
Similarity measures and attribute selection for case-based reasoning in transcatheter aortic valve implantation
In a clinical decision support system, the purpose of case-based reasoning is to help clinicians make convenient decisions for diagnoses or interventional gestures. Past experience, which is represented by a case-base of previous patients, is exploited to solve similar current problems using four steps—retrieve, reuse, revise, and retain. The proposed case-based reasoning has been focused on transcatheter aortic valve implantation to respond to clinical issues pertaining vascular access and prosthesis choices. The computation of a relevant similarity measure is an essential processing step employed to obtain a set of retrieved cases from a case-base. A hierarchical similarity measure that is based on a clinical decision tree is proposed to better integrate the clinical knowledge, especially in terms of case representation, case selection and attributes weighting. A case-base of 138 patients is used to evaluate the case-based reasoning performance, and retrieve- and reuse-based criteria have been considered. The sensitivity for the vascular access and the prosthesis choice is found to 0.88 and 0.94, respectively, with the use of the hierarchical similarity measure as opposed to 0.53 and 0.79 for the standard similarity measure. Ninety percent of the suggested solutions are correctly classified for the proposed metric when four cases are retrieved. Using a dedicated similarity measure, with relevant and weighted attributes selected through a clinical decision tree, the set of retrieved cases, and consequently, the decision suggested by the case-based reasoning are substantially improved over state-of-the-art similarity measures.
- 3 September 2020
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 15 (9) , e0238463
Open AccessSimilarity measures and attribute selection for case-based reasoning in transcatheter aortic valve implantation
In a clinical decision support system, the purpose of case-based reasoning is to help clinicians make convenient decisions for diagnoses or interventional gestures. Past experience, which is represented by a case-base of previous patients, is exploited to solve similar current problems using four steps—retrieve, reuse, revise, and retain. The proposed case-based reasoning has been focused on transcatheter aortic valve implantation to respond to clinical issues pertaining vascular access and prosthesis choices. The computation of a relevant similarity measure is an essential processing step employed to obtain a set of retrieved cases from a case-base. A hierarchical similarity measure that is based on a clinical decision tree is proposed to better integrate the clinical knowledge, especially in terms of case representation, case selection and attributes weighting. A case-base of 138 patients is used to evaluate the case-based reasoning performance, and retrieve- and reuse-based criteria have been considered. The sensitivity for the vascular access and the prosthesis choice is found to 0.88 and 0.94, respectively, with the use of the hierarchical similarity measure as opposed to 0.53 and 0.79 for the standard similarity measure. Ninety percent of the suggested solutions are correctly classified for the proposed metric when four cases are retrieved. Using a dedicated similarity measure, with relevant and weighted attributes selected through a clinical decision tree, the set of retrieved cases, and consequently, the decision suggested by the case-based reasoning are substantially improved over state-of-the-art similarity measures.
- 11 November 2019
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 15 (2) , 277-285
Fusion of 3D real-time echocardiography and cine MRI using a saliency analysis
This paper presents a novel 3D multimodal registration strategy to fuse 3D real-time echocardiography images with cardiac cine MRI images. This alignment is performed in a saliency space, which is designed to maximize similarity between the two imaging modalities. This fusion improves the quality of the available information.
- 11 November 2019
- Published by Springer Nature in International Journal of Computer Assisted Radiology and Surgery
- Vol. 15 (2) , 277-285
Fusion of 3D real-time echocardiography and cine MRI using a saliency analysis
This paper presents a novel 3D multimodal registration strategy to fuse 3D real-time echocardiography images with cardiac cine MRI images. This alignment is performed in a saliency space, which is designed to maximize similarity between the two imaging modalities. This fusion improves the quality of the available information.
- 14 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 33 (6) , 1363-1372
Multimodal Registration and Data Fusion for Cardiac Resynchronization Therapy Optimization
Cardiac resynchronization therapy (CRT) has been shown to improve cardiovascular function in specific patients suffering from heart failure. This procedure still needs to be optimized to overcome the high rate of implanted patients that do not respond to this therapy. We propose in this work a better characterization of the electro-mechanical (EM) coupling of each region of the left ventricle (LV) that could be useful to precise the best implantation site. A new descriptor is proposed with the extraction of local electro-mechanical delays. Their measurement is based on the fusion of anatomical, functional and electrical data acquired using computed tomography (CT), speckle tracking echocardiography (STE), and electro-anatomical mappings (EAM). We propose a workflow to place multimodal data in the same geometrical referential system and to extract local electro-mechanical descriptors. It implies the fusion of electrical and mechanical data on a 3D+ t anatomical model of the LV. It mainly consists in four steps: 1) the modeling of the endocardium using a dynamic surface estimated from CT images; 2) the semi-interactive registration of EAM data and CT images; 3) the automatic registration of STE data on the dynamic model, using a metric based on Fourier descriptors and dynamic time warping; 4) the temporal alignment between EAM and STE and the estimation of local electro-mechanical delays. The proposed process has been applied to real data corresponding to five patients undergoing CRT. Results show that local electro-mechanical delays provide meaningful information on the local characterization of the LV and may be useful for the optimal pacing site selection in CRT.
- 14 March 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Medical Imaging
- Vol. 33 (6) , 1363-1372
Multimodal Registration and Data Fusion for Cardiac Resynchronization Therapy Optimization
Cardiac resynchronization therapy (CRT) has been shown to improve cardiovascular function in specific patients suffering from heart failure. This procedure still needs to be optimized to overcome the high rate of implanted patients that do not respond to this therapy. We propose in this work a better characterization of the electro-mechanical (EM) coupling of each region of the left ventricle (LV) that could be useful to precise the best implantation site. A new descriptor is proposed with the extraction of local electro-mechanical delays. Their measurement is based on the fusion of anatomical, functional and electrical data acquired using computed tomography (CT), speckle tracking echocardiography (STE), and electro-anatomical mappings (EAM). We propose a workflow to place multimodal data in the same geometrical referential system and to extract local electro-mechanical descriptors. It implies the fusion of electrical and mechanical data on a 3D+ t anatomical model of the LV. It mainly consists in four steps: 1) the modeling of the endocardium using a dynamic surface estimated from CT images; 2) the semi-interactive registration of EAM data and CT images; 3) the automatic registration of STE data on the dynamic model, using a metric based on Fourier descriptors and dynamic time warping; 4) the temporal alignment between EAM and STE and the estimation of local electro-mechanical delays. The proposed process has been applied to real data corresponding to five patients undergoing CRT. Results show that local electro-mechanical delays provide meaningful information on the local characterization of the LV and may be useful for the optimal pacing site selection in CRT.
- 6 February 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 17 (2) , 336-345
Coronary Vein Extraction in MSCT Volumes Using Minimum Cost Path and Geometrical Moments
This work deals with the extraction of patient-specific coronary venous anatomy in preoperative multislice computed tomography (MSCT) volumes. A hybrid approach has been specifically designed for low-contrast vascular structure detection. It makes use of a minimum cost path technique with a Fast-Marching front propagation to extract the vessel centerline. A second procedure was applied to refine the position of the path and estimate the local radius along the vessel. This was achieved with an iterative multiscale algorithm based on geometrical moments. Parameter tuning was performed using a dedicated numerical phantom, and then the algorithm was applied to extract the coronary venous system. Results are provided on three MSCT volume sequences acquired for patients selected for a cardiac resynchronization therapy procedure. A visibility study was carried out by a medical expert who labeled venous segments on a set of 18 volumes. A comparison with two other Fast-Marching techniques and a geometrical moment based tracking method is also reported.
- 6 February 2013
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Journal of Biomedical and Health Informatics
- Vol. 17 (2) , 336-345
Coronary Vein Extraction in MSCT Volumes Using Minimum Cost Path and Geometrical Moments
This work deals with the extraction of patient-specific coronary venous anatomy in preoperative multislice computed tomography (MSCT) volumes. A hybrid approach has been specifically designed for low-contrast vascular structure detection. It makes use of a minimum cost path technique with a Fast-Marching front propagation to extract the vessel centerline. A second procedure was applied to refine the position of the path and estimate the local radius along the vessel. This was achieved with an iterative multiscale algorithm based on geometrical moments. Parameter tuning was performed using a dedicated numerical phantom, and then the algorithm was applied to extract the coronary venous system. Results are provided on three MSCT volume sequences acquired for patients selected for a cardiac resynchronization therapy procedure. A visibility study was carried out by a medical expert who labeled venous segments on a set of 18 volumes. A comparison with two other Fast-Marching techniques and a geometrical moment based tracking method is also reported.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2011 (1094687X) , 8094-8097
Similarity enhancement for automatic segmentation of cardiac structures in computed tomography volumes
The aim of this research is proposing a 3-D similarity enhancement technique useful for improving the segmentation of cardiac structures in Multi-Slice Computerized Tomography (MSCT) volumes. The similarity enhancement is obtained by subtracting the intensity of the current voxel and the gray levels of their adjacent voxels in two volumes resulting after preprocessing. Such volumes are: a. - a volume obtained after applying a Gaussian distribution and a morphological top-hat filter to the input and b. - a smoothed volume generated by processing the input with an average filter. Then, the similarity volume is used as input to a region growing algorithm. This algorithm is applied to extract the shape of cardiac structures, such as left and right ventricles, in MSCT volumes. Qualitative and quantitative results show the good performance of the proposed approach for discrimination of cardiac cavities.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2011 (1094687X) , 8094-8097
Similarity enhancement for automatic segmentation of cardiac structures in computed tomography volumes
The aim of this research is proposing a 3-D similarity enhancement technique useful for improving the segmentation of cardiac structures in Multi-Slice Computerized Tomography (MSCT) volumes. The similarity enhancement is obtained by subtracting the intensity of the current voxel and the gray levels of their adjacent voxels in two volumes resulting after preprocessing. Such volumes are: a. - a volume obtained after applying a Gaussian distribution and a morphological top-hat filter to the input and b. - a smoothed volume generated by processing the input with an average filter. Then, the similarity volume is used as input to a region growing algorithm. This algorithm is applied to extract the shape of cardiac structures, such as left and right ventricles, in MSCT volumes. Qualitative and quantitative results show the good performance of the proposed approach for discrimination of cardiac cavities.