    Structure Analysis of the Fractionator Overhead Vapor Line of a Delayed Coker Unit

    by Chun-Lang Yeh, Yu-Hsi Chung

    In view of the great impact of the pipeline system in a delayed coker unit (DCU) on production and operation safety, we applied computational fluid dynamics (CFD) to investigate the flow in a fractionator overhead vapor line connected to an air cooler in a previous study. The causes of the pipeline damage and the strategies to alleviate the occurrence of the damage were discussed. It is found that if two 24″ pipes are connected and five 18″ pipes are also connected, the force uniformity can be improved, and the forces on the caps, reducers, and T-junctions can be reduced. In this paper, we further applied the finite element method to perform structure analysis to confirm the strength of the original and the improved pipeline system. It is found that the static stress is larger when the pipelines are connected. The first four modes of the pipeline vibration are primarily affected by the vibration of the 30″ main pipe, while the fifth and the sixth modes are primarily affected by the vibration of the smaller pipes. In the case of a magnitude 1 earthquake (parallel mode) and a magnitude 2 wind, the maximum harmonic response stresses (stresses obtained from harmonic response analysis) occur at the same locations. After the pipelines are connected, some positions of the maximum harmonic response stresses are shifted from the 30″ main pipe to the 24″ pipe. In terms of the wind effect, the pipelines connected or unconnected can both withstand moderate typhoons of magnitude 13 without fatigue damage. In terms of the seismic effect, the pipelines connected can withstand a strong earthquake of magnitude 5(+) without fatigue damage, while the pipelines unconnected can withstand a very strong earthquake of magnitude 6(−) without fatigue damage, which is better than the pipelines connected. Under the action of a magnitude 17 severe typhoon, the stresses for the pipelines connected or unconnected are both lower than the yield strength and the ultimate tensile strength (UTS). There is no danger of immediate damage in terms of the wind effect. The pipelines connected or unconnected can withstand magnitude 7 earthquakes up to accelerations of 1718 gal (17.18 m/s2) and 2236 gal (22.36 m/s2), respectively, without exceeding the UTS. The pipelines unconnected are slightly better than the pipelines connected in terms of earthquake resistance. The purpose of this series study is to explore the flow development and the structural strength of the DCU pipeline system to improve its operational safety.


  • Open Access

    A Parametric Study on the Performance of a Helical Type of Internally Finned Tube

    by Chun-Lang Yeh, Dong-Long Wu, Qi-Ying Cai, Shi-Yi Yang, Xuan-Jun Lin, Geng-Hong Liu

    We study the performance of a helical type of internally finned tube (HIFT), using computational fluid dynamics (CFD) to obtain optimal temperature uniformity and reduce the pressure drop. In comparison with a bare tube, the HIFT improved the temperature uniformity with a helix length of 10 d, which was enough to obtain satisfactory temperature uniformity. A smaller helix interval angle and a smaller helix pitch yielded a larger pressure drop. The temperature of the HIFT decreased with an increase in the helix pitch.


  • Open Access

    Parametric Study on Performance of Straight Type of Internally Finned Tube

    by Chun-Lang Yeh, Dong-Long Wu, Qi-Ying Cai, Yu-Xi Chung, Chang-Xin Liu, Zhi-Qian Wu

    The performance of a straight type of internally finned tube (SIFT) is studied using computational fluid dynamics (CFD). It is found that a longer fin yields a larger pressure drop that is nearly proportional to the fin length. When the fin length is larger than 30 d, the pressure drop is greater than that of a bare tube. The temperature uniformity decreases with the fin length of the SIFT. Furthermore, a smaller fin angle yields a larger pressure drop, while a larger fin angle yields better temperature uniformity. A larger contraction yields a larger pressure drop, too.

  • Open Access

    Reinforcement Design of the Support Frame of a Petrochemical Heater

    by Chun-Lang Yeh

    In this paper, we investigated the operating security of the support frame of a petrochemical heater under the action of a strong wind. When the fatigue limit was exceeded, the support frame was damaged. We monitored the heater before reinforcement and then applied the finite element method to analyze and compare nine different kinds of reinforcement methods for the support frame. From the results of the finite element analysis, fatigue failure of the support frame before reinforcement occurred at locations where the computed stresses from the finite element analysis were large, thus partially justifying the adequacies of the present analysis methods and results. Among the nine reinforcement methods, we suggest case 9 to reinforce a support frame so that its operating security under the action of a strong wind can be improved. At the end of this paper, several future studies are suggested, including verification of the reinforcement for the support frame and the establishment of the system for automatic stress monitoring and analysis.

  • Open Access

    Effect of Burner Operation on the Catalyst Tube Lifetime of a Steam Methane Reformer: A Numerical Study

    by Chun-Lang Yeh

    In this paper, the catalyst tube lifetime of a practical steam methane reformer is analyzed numerically. The effect of burner operating mode on the flow development, hydrogen yield, and catalyst tube lifetime is discussed, with the aim of improving the reformer performance. The results of this study reveal that using the periodic boundary conditions, the temperatures and hydrogen yields obtained are much lower than the experimental values and the pressures are much lower than those using the real model. This results in overestimating the catalyst tube lifetime and underestimating the reformer operation risk. The catalyst tubes in the downstream area have longer lifetimes, while those in the upstream area have shorter lifetimes. Turning the upstream burners off is more efficient to the catalyst tube lifetime, while turning off the central groups of burners is less efficient. The main drawback of turning off burners is the decrease of hydrogen yield.


  • Open Access

    Numerical Investigation of the Effects of Steam Mole Fraction and the Inlet Velocity of Reforming Reactants on an Industrial-Scale Steam Methane Reformer

    by Chun-Lang Yeh

    Steam methane reforming (SMR) is the most common commercial method of industrial hydrogen production. Control of the catalyst tube temperature is a fundamental demand of the reformer design because the tube temperature must be maintained within a range that the catalysts have high activity and the tube has minor damage. In this paper, the transport and chemical reaction in an industrial-scale steam methane reformer are simulated using computational fluid dynamics (CFD). Two factors influencing the reformer temperature, hydrogen yield and stress distribution are discussed: (1) the mole fraction of steam (YH2O) and (2) the inlet velocity of the reforming reactants. The purpose of this paper is to get a better understanding of the flow and thermal development in a reformer and thus, to make it possible to improve the performance and lifetime of a steam reformer. It is found that the lowest temperature at the reforming tube surface occurs when YH2O is 0.5. Hydrogen yield has the highest value when YH2O is 0.5. The wall shear stress at the reforming tube surface is higher at a higher YH2O. The surface temperature of a reforming tube increases with the inlet velocity of the reforming reactants. Finally, the wall shear stress at the reforming tube surface increases with the inlet velocity of the reforming reactants.


  • Open Access

    Numerical study of the burner parameters on the thermal field in a sulfur recovery unit thermal reactor

    by Chun-Lang Yeh

    A sulfur recovery unit (SRU) thermal reactor is the most important equipment in a sulfur plant and is negatively affected by high temperature operations. In this paper, the effect of burner parameters, including the clearance of the acid gas tip and the inlet air swirler angle, on the thermal field in a SRU thermal reactor are investigated numerically, with the aim to reduce the high temperature inside the thermal reactor and to ensure an acceptable sulfur recovery. The simulation results show that the burner with a smaller clearance of the acid gas tip produces a lower temperature, a lower exit SO2 mole fraction and higher exit S2 and H2S mole fractions. Among the clearancs of the acid gas tip investigated, the horizontal clearance of 152.4mm and vertical clearance of 240mm yield the lowest temperature, exit SO2 mole fraction and highest exit S2, H2S mole fractions. The burner with a smaller inlet air swirler angle produces a higher temperature, a higher exit SO2 mole fraction and lower exit S2 and H2S mole fractions. Among the swirler angles investigated, 60° yields the lowest temperature, exit SO2 mole fraction and highest exit S2 , H2S mole fractions.


  • Open Access

    NOx Pollution Analysis for a Sulfur Recovery Unit Thermal Reactor

    by Chun-Lang Yeh

    A sulfur recovery unit (SRU) thermal reactor is the most important equipment in a sulfur plant. It is negatively affected by high temperature operations. In this paper, NOx emissions from the SRU thermal reactors are simulated. Both the prototype thermal reactor and its modifications, including changing fuel mass fraction, changing inlet air quantity, changing inlet oxygen mole fraction, and changing burner geometry, are analyzed to investigate their influences on NOx emissions. In respect of the fuel mass fraction, the simulation results show that the highest NO emission occurs at a zone 1 fuel mass fraction of 0.375, around which the reactor maximum temperature and the zone 1 average temperature reach maximum values. Concerning the inlet air quantity, the highest NO emission occurs when the inlet air quantity is 2.4 times the designed inlet air quantity. This is very close to the inlet air quantity at which the maximum average temperature occurs. Regarding the inlet oxygen mole fraction, the NO emission increases as the inlet oxygen mole fraction increases. With regard to the burner geometry, the NO emission increases as the clearance of the burner acid gas tip increases. In addition, the NO emission increases as the swirling strength increases.

  • THE EFFECTS OF INLET AIR QUANTITY AND INLET OXYGEN MOLE FRACTION ON THE COMBUSTION AND FLUID FLOW IN A SULFUR RECOVERY UNIT THERMAL REACTOR

    by Chun-Lang Yeh

    Owing to the high temperature inside a sulfur recovery unit (SRU) thermal reactor, detailed experimental measurements are difficult. In the author’s previous studies, several methods have been assessed to resolve the abnormality of the SRU thermal reactor under high temperature operation. This paper presents a new easier and more economical method. The effects of inlet air quantity and inlet O2 mole fraction on the combustion and fluid flow in a SRU thermal reactor are investigated numerically. The flow field temperature, S2 recovery, H2S mole fraction, and SO2 emissions are analyzed. This paper provides a guideline for adjusting the inlet air quantity and the inlet O2 mole fraction to reduce the high temperature inside a thermal reactor and to ensure an acceptable sulfur recovery.