Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Samo B. Hocevar has a total of 98 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Integrated Kinetic and Thermochemical Analysis of Aqueous-Phase Naphthalene Nitration and Its Contribution to Brown Carbon

    by Kristijan Vidović, Ivana Drventić, Filip Cernatič, Alen Albreht, Davide Vione, Samo Hočevar

    Brown carbon (BrC) is a key light-absorbing component of atmospheric aerosols, yet its sources, particularly those driven by aqueous-phase chemistry, remain poorly constrained, leading to an underestimation of its contribution. Here, we demonstrate efficient nitration and hydroxylation of naphthalene under atmospheric aqueous-phase conditions in the presence of HONO and simulated sunlight, yielding two BrC-active products: 2-nitro-1-naphthol and 1-nitronaphthalene. Contrary to prevailing assumptions, 2-nitro-1-naphthol is the dominant product under atmospherically relevant conditions, whereas 1-nitronaphthalene forms only at elevated solute levels characteristic of aerosol liquid water. The OH-initiated nitration mechanism is elucidated by combining macroscopic kinetic modeling with DFT-based thermochemical calculations, revealing the catalytic role of HONO and the importance of aqueous-phase stabilization of key intermediates. By integrating degradation kinetics (kapp_OH), pathway-specific formation rates (kNOH and kNN), and time-resolved absorbance data, we derive BrC mass absorption coefficients (MACs) of 0.8–20.7 m2 g–1. These values exceed those reported for gas-phase naphthalene nitration, highlighting the importance of aqueous-phase aromatic chemistry for atmospheric radiative forcing.

  • Open Access

    Study of a Sensitive and Selective Electrochemical Biosensor for Glucose Based on Bi2Ru2O7 Pyrochlore Clusters Combined with MWCNTs

    by Jelena Isailović, Aleksandra Dapčević, Milan Žunić, Matjaž Finšgar, Kristijan Vidović, Nikola Tasić, Samo B. Hočevar

    The development of sensitive, selective, and reliable glucose biosensors remains a persistent challenge in clinical diagnostics. In this study, we exploited the advantageous (electro)catalytic properties of bismuth ruthenate (Bi2Ru2O7) pyrochlore clusters, known for their high surface activity and metallic-like conductivity, and the favorable physicochemical properties of multi-walled carbon nanotubes (MWCNTs) by combining them with glucose oxidase (GOD) in a sensitive and selective disposable glucose biosensor. The integration of Bi2Ru2O7 enabled an enhanced and more reproducible response of the biosensor along with fast and improved communication between the supporting electrode and the upper biosensing layer. The architecture of the biosensor involves the deposition of an MWCNT layer on a ferrocyanide-modified screen-printed carbon electrode (FCN-SPCE), followed by the application of a biorecognition layer including GOD and Bi2Ru2O7 clusters. The voltammetric biosensor showed excellent electroanalytical performance, capable of detecting low glucose concentrations with a detection limit of 40 µM along with a linear response across the examined concentration range of 1.0–20.0 mM. The biosensor exhibited good reproducibility with a relative standard deviation (RSD) of 1.2% and interference-free operation against several of the most common interfering compounds. The practical applicability of the biosensor was demonstrated by the determination of glucose in a real serum sample spiked with different concentrations of glucose.


  • Open Access

    Comparative Analysis of Synthesis Routes and Aluminum Doping Effects on Nickel-Manganese-Cobalt Type Cathode Material

    by Yu-Sheng Chen, Elena Tchernychova, Samo Hočevar, Robert Dominko, Władysław Wieczorek

    This study presents a comprehensive analysis of the synthesis techniques and the effects of aluminum doping on nickel-manganese-cobalt (NMC) 811 cathode materials. Our research focuses on the comparison of two different synthesis methods. Hydroxide co-precipitation is followed by solid-state calcination for polycrystalline (PC) cathodes and molten salt calcination for single-crystalline (SC) cathodes. In addition, the study systematically integrates aluminum dopants at different stages of these processes. This study aims to examine how various doping methods affect the structural characteristics, morphological features, and electrochemical performance of NMC cathodes.This investigation employs a thorough characterization approach, utilizing techniques such as X-ray diffraction (XRD), various microscopy methods, and galvanostatic cycling tests, our results illustrate the complexity of the synthesis parameters that influence the capacity retention and performance of the samples produced.


  • Open Access

    Protein Stacking on the APTES-Functionalized Pyrochlore Bi2Ru2O7 Clusters for Ultrasensitive and Selective Immunosensing

    by Nikola Tasić, Nika Vranešič, Dino Metarapi, Kristina Mervič, Milan Žunić, Aleksandra Dapčević, Matjaž Finšgar, Samo B. Hočevar

    With their unique physicochemical properties, such as metallic-like conductivity, favorable (electro)catalytic properties, electrochemical stability, and ease of functionalization, pyrochlores have found applications in various fields such as solid oxide fuel cells, batteries, thick film resistors, and temperature sensors; however, there are no reports on their application in electrochemical immunosensing. In this study, we exploited the (electro)catalytic nature and stability of the pyrochlore Bi2Ru2O7 clusters silanized with (3-aminopropyl)triethoxysilane (APTES) to demonstrate their potential for the effective stacking of functional proteins. Characterization of the clusters by XPS disclosed a dual environment of Bi, also indicating the presence of Bi2O3 alongside APTES-Bi2Ru2O7 clusters and, importantly, the predominant involvement of pyrochlore moieties in subsequent protein stacking. After stacking protein A and antibodies, the immunosensor revealed a nearly interference-free operation, high sensitivity, a detection limit of 118 fM SARS-CoV-2 spike protein, and operation in a wide examined concentration range of 10-5-10-1 μg mL-1 with an r2 of 0.98. In combination with a short incubation time of 30 min, the pyrochlore-based immunosensor provides a solid platform for future point-of-need applications.


  • Open Access

    Study of V2CTx-MXene Based Immunosensor for Sensitive Label-Free Impedimetric Detection of SARS-CoV-2 Spike Protein

    by Nikola Tasić, Ivan Konjević, Alnilan Lobato, Dino Metarapi, Matjaž Finšgar, Filipa M. Oliveira, Zděnek Sofer, Rui Gusmão, Xueji Zhang, Samo B. Hočevar

    Rapid and reliable immunosensing is undoubtedly one of the priorities in the efficient management and combat against a pandemic, as society has experienced with the SARS-CoV-2 outbreak; simple and cost-effective sensing strategies are at the forefront of these efforts. In this regard, 2D-layered MXenes hold great potential for electrochemical biosensing due to their attractive physicochemical properties. Herein, we present a V2CTx MXene-based sensing layer as an integral part of a label-free immunosensor for sensitive and selective detection of the SARS-CoV-2 spike protein. The sensor was fabricated on a supporting screen-printed carbon electrode using Nafion as an immobilizing agent for MXene and glutaraldehyde, the latter enabling effective binding of protein A for further site-oriented immobilization of anti-SARS-CoV-2 antibodies. A thorough structural analysis of the sensor architecture was carried out, and several key parameters affecting the fabrication and analytical performance of the immunosensor were investigated and optimized. The immunosensor showed excellent electroanalytical performance in combination with an impedimetric approach and exhibited a low detection limit of only 45 fM SARS-CoV-2 spike protein. Its practical applicability was successfully demonstrated by measuring the spike protein in a spiked artificial nasopharyngeal fluid sample.


  • Open Access

    Do bromine and surface-active substances influence the coastal atmospheric particle growth?

    by Kristijan Vidović, Samo Hočevar, Irena Grgić, Dino Metarapi, Iva Dominović, Boris Mifka, Asta Gregorič, Balint Alfoldy, Irena Ciglenečki


  • Open Access

    Structural basis for the unique molecular properties of broad-range phospholipase C from Listeria monocytogenes

    by Nejc Petrišič, Maksimiljan Adamek, Andreja Kežar, Samo B. Hočevar, Ema Žagar, Gregor Anderluh, Marjetka Podobnik

    Listeriosis is one of the most serious foodborne diseases caused by the intracellular bacterium Listeria monocytogenes. Its two major virulence factors, broad-range phospholipase C (LmPC-PLC) and the pore-forming toxin listeriolysin O (LLO), enable the bacterium to spread in the host by destroying cell membranes. Here, we determine the crystal structure of LmPC-PLC and complement it with the functional analysis of this enzyme. This reveals that LmPC-PLC has evolved several structural features to regulate its activity, including the invariant position of the N-terminal tryptophan (W1), the structurally plastic active site, Zn2+-dependent activity, and the tendency to form oligomers with impaired enzymatic activity. We demonstrate that the enzymatic activity of LmPC-PLC can be specifically inhibited by its propeptide added in trans. Furthermore, we show that the phospholipase activity of LmPC-PLC facilitates the pore-forming activity of LLO and affects the morphology of LLO oligomerization on lipid membranes, revealing the multifaceted synergy of the two virulence factors.


  • Open Access

    Correction to “Study of Chitosan-Stabilized Ti3C2Tx MXene for Ultrasensitive and Interference-Free Detection of Gaseous H2O2”

    by Jelena Isailović, Ana Oberlintner, Uroš Novak, Matjaž Finšgar, Filipa M. Oliveira, Jan Paštika, Zdeněk Sofer, Nikola Tasić, Rui Gusmão, Samo B. Hočevar


  • Open Access

    Study of Chitosan-Stabilized Ti3C2Tx MXene for Ultrasensitive and Interference-Free Detection of Gaseous H2O2

    by Jelena Isailović, Ana Oberlintner, Uroš Novak, Matjaž Finšgar, Filipa M. Oliveira, Jan Paštika, Zdeněk Sofer, Nikola Tasić, Rui Gusmão, Samo B. Hočevar

    The development of sensitive, selective, and reliable gaseous hydrogen peroxide (H2O2) sensors operating at room temperature still represents a remaining challenge. In this work, we have investigated and combined the advantageous properties of a two-dimensional Ti3C2Tx MXene material that exhibits a large specific surface area and high surface activity, with favorable conducting and stabilizing properties of chitosan. The MXene-chitosan membrane was deposited on the ferrocyanide-modified screen-printed working carbon electrode, followed by applying poly(acrylic acid) as an electrolyte and accumulation medium for gaseous H2O2. The sensor showed highly sensitive and selective electroanalytical performance for detecting trace concentrations of gaseous H2O2 with a very low detection limit of 4 μg m-3 (4 ppbv), linear response in the studied concentration range of 0.5-30.0 mg m-3, and good reproducibility with an RSD of 1.3%. The applicability of the sensor was demonstrated by point-of-interest detection of gaseous H2O2 during the real hair bleaching process with a 9 and 12% H2O2 solution.


  • Open Access

    RBD-Modified Polyaniline-Based Label-Free Immunosensor for Sensitive Impedimetric Detection of Anti-SARS-CoV-2 Antibodies

    by Tea Romih, Nikola Tasić, Lea Bibič, Ajda Beltram, Ika Fazarinc, Mojca Benčina, Roman Jerala, Samo B. Hočevar

    The emergence of the SARS-CoV-2 virus and the associated pandemic has affected the entire human population. Human susceptibility to the virus has highlighted a tremendous need for affordable diagnostic systems to manage the pandemic and monitor the effectiveness of vaccination. We have developed a simple and label-free electrochemical immunosensor for the detection of human anti-SARS-CoV-2 IgG antibodies, which consists of a supporting screen-printed carbon electrode (SPCE) modified with an electrodeposited polyaniline film and glutaraldehyde, allowing effective immobilization of the SARS-CoV-2 spike glycoprotein receptor-binding domain (RBD) as a biorecognition element. The impedimetric immunosensor showed a linear response over a wide concentration range of 0.01–10 μg mL−1, that is, 67 pM–6.7 nM, with a low detection limit of 25.9 pM. A dual working electrode configuration with a built-in negative control unit was demonstrated for practical field applications. The immunosensor was successfully used in a real serum sample from an infected patient and showed good reproducibility and fair agreement with ELISA. An optional amplification step with secondary goat anti-human IgG antibodies was demonstrated, resulting in an extended linear range and a detection limit as low as 0.93 pM.