NTNikola Tasić

Nikola Tasić

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Nikola Tasić has a total of 146 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Electrocatalytically Amplified Immunosensing Enabled by Titanium Oxynitride‐Supported Ru Nanodots on Graphene Oxide Hybrid Architecture

    by Mitja Koderman, Milutin Smiljanić, Filip Cernatič, Marjan Bele, Francisco Ruiz‐Zepeda, Nejc Hodnik, Mitja Kolar, Samo B. Hočevar, Nikola Tasić

    Electrocatalytically amplified electrochemical immunosensing is a powerful strategy for sensitive and interference‐free detection of biomarkers. Herein, we report a high‐performance electrochemical immunosensor enabled by a hierarchical hybrid architecture comprising Ru nanodots anchored on titanium oxynitride nanoflakes dispersed on graphene oxide (Ru/TiON‐GO), linked via APTES to biorecognition building blocks. The engineered heterostructure exhibits advanced electrocatalytic activity, arising from synergistic electronic coupling between Ru nanodots and the highly conductive TiON‐GO support, effectively promoting interfacial electron transport between the electrocatalytic surface and the [Fe(CN) 6 ] 3−/4− redox probe. Leveraging this electrocatalytic platform, a prostate‐specific antigen (PSA) impedimetric immunosensor was constructed, achieving a limit of detection of 0.06 ng mL −1 (2.3 pM) and a wide linear response covering clinically relevant concentration range. The immunosensor demonstrates excellent selectivity in human serum, operating in interference‐free mode even in the presence of common coexisting biomolecules, highlighting suitability for medical diagnostics. Density functional theory calculations further elucidate the origin of the enhanced electrocatalytic performance, with charge density difference plots and density of states analysis revealing Ru‐driven electron redistribution and increased density of states near the Fermi level. This work establishes the Ru/TiON‐GO nanocomposite as a robust electrocatalytic platform for advanced immunosensing applications, paving the way toward next‐generation electrochemical diagnostic devices.

  • Open Access

    Recent advances in electrochemical genosensing

    by Alnilan Lobato, Mitja Koderman, Nika Vranešič, Samo B. Hočevar, Nikola Tasić


  • Open Access

    Study of a Sensitive and Selective Electrochemical Biosensor for Glucose Based on Bi2Ru2O7 Pyrochlore Clusters Combined with MWCNTs

    by Jelena Isailović, Aleksandra Dapčević, Milan Žunić, Matjaž Finšgar, Kristijan Vidović, Nikola Tasić, Samo B. Hočevar

    The development of sensitive, selective, and reliable glucose biosensors remains a persistent challenge in clinical diagnostics. In this study, we exploited the advantageous (electro)catalytic properties of bismuth ruthenate (Bi2Ru2O7) pyrochlore clusters, known for their high surface activity and metallic-like conductivity, and the favorable physicochemical properties of multi-walled carbon nanotubes (MWCNTs) by combining them with glucose oxidase (GOD) in a sensitive and selective disposable glucose biosensor. The integration of Bi2Ru2O7 enabled an enhanced and more reproducible response of the biosensor along with fast and improved communication between the supporting electrode and the upper biosensing layer. The architecture of the biosensor involves the deposition of an MWCNT layer on a ferrocyanide-modified screen-printed carbon electrode (FCN-SPCE), followed by the application of a biorecognition layer including GOD and Bi2Ru2O7 clusters. The voltammetric biosensor showed excellent electroanalytical performance, capable of detecting low glucose concentrations with a detection limit of 40 µM along with a linear response across the examined concentration range of 1.0–20.0 mM. The biosensor exhibited good reproducibility with a relative standard deviation (RSD) of 1.2% and interference-free operation against several of the most common interfering compounds. The practical applicability of the biosensor was demonstrated by the determination of glucose in a real serum sample spiked with different concentrations of glucose.


  • Open Access

    Protein Stacking on the APTES-Functionalized Pyrochlore Bi2Ru2O7 Clusters for Ultrasensitive and Selective Immunosensing

    by Nikola Tasić, Nika Vranešič, Dino Metarapi, Kristina Mervič, Milan Žunić, Aleksandra Dapčević, Matjaž Finšgar, Samo B. Hočevar

    With their unique physicochemical properties, such as metallic-like conductivity, favorable (electro)catalytic properties, electrochemical stability, and ease of functionalization, pyrochlores have found applications in various fields such as solid oxide fuel cells, batteries, thick film resistors, and temperature sensors; however, there are no reports on their application in electrochemical immunosensing. In this study, we exploited the (electro)catalytic nature and stability of the pyrochlore Bi2Ru2O7 clusters silanized with (3-aminopropyl)triethoxysilane (APTES) to demonstrate their potential for the effective stacking of functional proteins. Characterization of the clusters by XPS disclosed a dual environment of Bi, also indicating the presence of Bi2O3 alongside APTES-Bi2Ru2O7 clusters and, importantly, the predominant involvement of pyrochlore moieties in subsequent protein stacking. After stacking protein A and antibodies, the immunosensor revealed a nearly interference-free operation, high sensitivity, a detection limit of 118 fM SARS-CoV-2 spike protein, and operation in a wide examined concentration range of 10-5-10-1 μg mL-1 with an r2 of 0.98. In combination with a short incubation time of 30 min, the pyrochlore-based immunosensor provides a solid platform for future point-of-need applications.


  • Open Access

    New electrochemical approach for assessing surface tension and its role in atmospheric particle growth

    by Kristijan Vidović, Samo B. Hočevar, Kumar Sarang, Ivan Konjević, Nikola Tasić, Irena Ciglenečki


  • Open Access

    Study of V2CTx-MXene Based Immunosensor for Sensitive Label-Free Impedimetric Detection of SARS-CoV-2 Spike Protein

    by Nikola Tasić, Ivan Konjević, Alnilan Lobato, Dino Metarapi, Matjaž Finšgar, Filipa M. Oliveira, Zděnek Sofer, Rui Gusmão, Xueji Zhang, Samo B. Hočevar

    Rapid and reliable immunosensing is undoubtedly one of the priorities in the efficient management and combat against a pandemic, as society has experienced with the SARS-CoV-2 outbreak; simple and cost-effective sensing strategies are at the forefront of these efforts. In this regard, 2D-layered MXenes hold great potential for electrochemical biosensing due to their attractive physicochemical properties. Herein, we present a V2CTx MXene-based sensing layer as an integral part of a label-free immunosensor for sensitive and selective detection of the SARS-CoV-2 spike protein. The sensor was fabricated on a supporting screen-printed carbon electrode using Nafion as an immobilizing agent for MXene and glutaraldehyde, the latter enabling effective binding of protein A for further site-oriented immobilization of anti-SARS-CoV-2 antibodies. A thorough structural analysis of the sensor architecture was carried out, and several key parameters affecting the fabrication and analytical performance of the immunosensor were investigated and optimized. The immunosensor showed excellent electroanalytical performance in combination with an impedimetric approach and exhibited a low detection limit of only 45 fM SARS-CoV-2 spike protein. Its practical applicability was successfully demonstrated by measuring the spike protein in a spiked artificial nasopharyngeal fluid sample.


  • Open Access

    Correction to “Study of Chitosan-Stabilized Ti3C2Tx MXene for Ultrasensitive and Interference-Free Detection of Gaseous H2O2”

    by Jelena Isailović, Ana Oberlintner, Uroš Novak, Matjaž Finšgar, Filipa M. Oliveira, Jan Paštika, Zdeněk Sofer, Nikola Tasić, Rui Gusmão, Samo B. Hočevar


  • Open Access

    Development of a simple gelatin-based sensing platform for the sensitive label-free impedimetric detection of SARS-CoV-2

    by Alnilan Lobato, Maja Šubic, Tea Romih, Lea Žibret, Dino Metarapi, Mojca Benčina, Roman Jerala, Kristijan Vidović, Samo B. Hočevar, Nikola Tasić


  • Open Access

    Study of Chitosan-Stabilized Ti3C2Tx MXene for Ultrasensitive and Interference-Free Detection of Gaseous H2O2

    by Jelena Isailović, Ana Oberlintner, Uroš Novak, Matjaž Finšgar, Filipa M. Oliveira, Jan Paštika, Zdeněk Sofer, Nikola Tasić, Rui Gusmão, Samo B. Hočevar

    The development of sensitive, selective, and reliable gaseous hydrogen peroxide (H2O2) sensors operating at room temperature still represents a remaining challenge. In this work, we have investigated and combined the advantageous properties of a two-dimensional Ti3C2Tx MXene material that exhibits a large specific surface area and high surface activity, with favorable conducting and stabilizing properties of chitosan. The MXene-chitosan membrane was deposited on the ferrocyanide-modified screen-printed working carbon electrode, followed by applying poly(acrylic acid) as an electrolyte and accumulation medium for gaseous H2O2. The sensor showed highly sensitive and selective electroanalytical performance for detecting trace concentrations of gaseous H2O2 with a very low detection limit of 4 μg m-3 (4 ppbv), linear response in the studied concentration range of 0.5-30.0 mg m-3, and good reproducibility with an RSD of 1.3%. The applicability of the sensor was demonstrated by point-of-interest detection of gaseous H2O2 during the real hair bleaching process with a 9 and 12% H2O2 solution.