Nikola Tasić
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Nikola Tasić has a total of 146 co-authors. Here are the top co-authors by number of shared publications:
- Samo B. Hocevar
Department of Analytical Chemistry, National Institute of Chemistry, Hajdrihova 19, 1000 Ljubljana, Slovenia
6 shared publications - Zorica Brankovic
University of Belgrade - Institute for Multidisciplinary Research, National Institute of the Republic of Serbia, Kneza Višeslava 1, 11030 Belgrade, Serbia
6 shared publications Goran Branković
Institute for Multidisciplinary Research Department of Materials Science University of Belgrade Belgrade Serbia
5 shared publications- Matjaž Finšgar
Faculty of Chemistry and Chemical Engineering, University of Maribor, Smetanova ulica 17, 2000 Maribor, Slovenia
5 shared publications Samo B. Hočevar
Department of Analytical Chemistry National Institute of Chemistry Ljubljana Slovenia
5 shared publications- Thiago Regis Longo Cesar Paixao
Universidade de São Paulo
5 shared publications
Latest Publications
- Open Access
Electrocatalytically Amplified Immunosensing Enabled by Titanium Oxynitride‐Supported Ru Nanodots on Graphene Oxide Hybrid Architecture
Electrocatalytically amplified electrochemical immunosensing is a powerful strategy for sensitive and interference‐free detection of biomarkers. Herein, we report a high‐performance electrochemical immunosensor enabled by a hierarchical hybrid architecture comprising Ru nanodots anchored on titanium oxynitride nanoflakes dispersed on graphene oxide (Ru/TiON‐GO), linked via APTES to biorecognition building blocks. The engineered heterostructure exhibits advanced electrocatalytic activity, arising from synergistic electronic coupling between Ru nanodots and the highly conductive TiON‐GO support, effectively promoting interfacial electron transport between the electrocatalytic surface and the [Fe(CN) 6 ] 3−/4− redox probe. Leveraging this electrocatalytic platform, a prostate‐specific antigen (PSA) impedimetric immunosensor was constructed, achieving a limit of detection of 0.06 ng mL −1 (2.3 pM) and a wide linear response covering clinically relevant concentration range. The immunosensor demonstrates excellent selectivity in human serum, operating in interference‐free mode even in the presence of common coexisting biomolecules, highlighting suitability for medical diagnostics. Density functional theory calculations further elucidate the origin of the enhanced electrocatalytic performance, with charge density difference plots and density of states analysis revealing Ru‐driven electron redistribution and increased density of states near the Fermi level. This work establishes the Ru/TiON‐GO nanocomposite as a robust electrocatalytic platform for advanced immunosensing applications, paving the way toward next‐generation electrochemical diagnostic devices.
Open AccessElectrocatalytically Amplified Immunosensing Enabled by Titanium Oxynitride‐Supported Ru Nanodots on Graphene Oxide Hybrid Architecture
Electrocatalytically amplified electrochemical immunosensing is a powerful strategy for sensitive and interference‐free detection of biomarkers. Herein, we report a high‐performance electrochemical immunosensor enabled by a hierarchical hybrid architecture comprising Ru nanodots anchored on titanium oxynitride nanoflakes dispersed on graphene oxide (Ru/TiON‐GO), linked via APTES to biorecognition building blocks. The engineered heterostructure exhibits advanced electrocatalytic activity, arising from synergistic electronic coupling between Ru nanodots and the highly conductive TiON‐GO support, effectively promoting interfacial electron transport between the electrocatalytic surface and the [Fe(CN) 6 ] 3−/4− redox probe. Leveraging this electrocatalytic platform, a prostate‐specific antigen (PSA) impedimetric immunosensor was constructed, achieving a limit of detection of 0.06 ng mL −1 (2.3 pM) and a wide linear response covering clinically relevant concentration range. The immunosensor demonstrates excellent selectivity in human serum, operating in interference‐free mode even in the presence of common coexisting biomolecules, highlighting suitability for medical diagnostics. Density functional theory calculations further elucidate the origin of the enhanced electrocatalytic performance, with charge density difference plots and density of states analysis revealing Ru‐driven electron redistribution and increased density of states near the Fermi level. This work establishes the Ru/TiON‐GO nanocomposite as a robust electrocatalytic platform for advanced immunosensing applications, paving the way toward next‐generation electrochemical diagnostic devices.
- Open Access
Recent advances in electrochemical genosensing
- Open Access
- 15 March 2025
- Published by MDPI AG in Chemosensors
- Vol. 13 (3) , 109
Study of a Sensitive and Selective Electrochemical Biosensor for Glucose Based on Bi2Ru2O7 Pyrochlore Clusters Combined with MWCNTs
The development of sensitive, selective, and reliable glucose biosensors remains a persistent challenge in clinical diagnostics. In this study, we exploited the advantageous (electro)catalytic properties of bismuth ruthenate (Bi2Ru2O7) pyrochlore clusters, known for their high surface activity and metallic-like conductivity, and the favorable physicochemical properties of multi-walled carbon nanotubes (MWCNTs) by combining them with glucose oxidase (GOD) in a sensitive and selective disposable glucose biosensor. The integration of Bi2Ru2O7 enabled an enhanced and more reproducible response of the biosensor along with fast and improved communication between the supporting electrode and the upper biosensing layer. The architecture of the biosensor involves the deposition of an MWCNT layer on a ferrocyanide-modified screen-printed carbon electrode (FCN-SPCE), followed by the application of a biorecognition layer including GOD and Bi2Ru2O7 clusters. The voltammetric biosensor showed excellent electroanalytical performance, capable of detecting low glucose concentrations with a detection limit of 40 µM along with a linear response across the examined concentration range of 1.0–20.0 mM. The biosensor exhibited good reproducibility with a relative standard deviation (RSD) of 1.2% and interference-free operation against several of the most common interfering compounds. The practical applicability of the biosensor was demonstrated by the determination of glucose in a real serum sample spiked with different concentrations of glucose.
- 15 March 2025
- Published by MDPI AG in Chemosensors
- Vol. 13 (3) , 109
Open AccessStudy of a Sensitive and Selective Electrochemical Biosensor for Glucose Based on Bi2Ru2O7 Pyrochlore Clusters Combined with MWCNTs
The development of sensitive, selective, and reliable glucose biosensors remains a persistent challenge in clinical diagnostics. In this study, we exploited the advantageous (electro)catalytic properties of bismuth ruthenate (Bi2Ru2O7) pyrochlore clusters, known for their high surface activity and metallic-like conductivity, and the favorable physicochemical properties of multi-walled carbon nanotubes (MWCNTs) by combining them with glucose oxidase (GOD) in a sensitive and selective disposable glucose biosensor. The integration of Bi2Ru2O7 enabled an enhanced and more reproducible response of the biosensor along with fast and improved communication between the supporting electrode and the upper biosensing layer. The architecture of the biosensor involves the deposition of an MWCNT layer on a ferrocyanide-modified screen-printed carbon electrode (FCN-SPCE), followed by the application of a biorecognition layer including GOD and Bi2Ru2O7 clusters. The voltammetric biosensor showed excellent electroanalytical performance, capable of detecting low glucose concentrations with a detection limit of 40 µM along with a linear response across the examined concentration range of 1.0–20.0 mM. The biosensor exhibited good reproducibility with a relative standard deviation (RSD) of 1.2% and interference-free operation against several of the most common interfering compounds. The practical applicability of the biosensor was demonstrated by the determination of glucose in a real serum sample spiked with different concentrations of glucose.
- Open Access
- 6 February 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (7) , 10792-10801
Protein Stacking on the APTES-Functionalized Pyrochlore Bi2Ru2O7 Clusters for Ultrasensitive and Selective Immunosensing
With their unique physicochemical properties, such as metallic-like conductivity, favorable (electro)catalytic properties, electrochemical stability, and ease of functionalization, pyrochlores have found applications in various fields such as solid oxide fuel cells, batteries, thick film resistors, and temperature sensors; however, there are no reports on their application in electrochemical immunosensing. In this study, we exploited the (electro)catalytic nature and stability of the pyrochlore Bi2Ru2O7 clusters silanized with (3-aminopropyl)triethoxysilane (APTES) to demonstrate their potential for the effective stacking of functional proteins. Characterization of the clusters by XPS disclosed a dual environment of Bi, also indicating the presence of Bi2O3 alongside APTES-Bi2Ru2O7 clusters and, importantly, the predominant involvement of pyrochlore moieties in subsequent protein stacking. After stacking protein A and antibodies, the immunosensor revealed a nearly interference-free operation, high sensitivity, a detection limit of 118 fM SARS-CoV-2 spike protein, and operation in a wide examined concentration range of 10-5-10-1 μg mL-1 with an r2 of 0.98. In combination with a short incubation time of 30 min, the pyrochlore-based immunosensor provides a solid platform for future point-of-need applications.
- 6 February 2025
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 17 (7) , 10792-10801
Open AccessProtein Stacking on the APTES-Functionalized Pyrochlore Bi2Ru2O7 Clusters for Ultrasensitive and Selective Immunosensing
With their unique physicochemical properties, such as metallic-like conductivity, favorable (electro)catalytic properties, electrochemical stability, and ease of functionalization, pyrochlores have found applications in various fields such as solid oxide fuel cells, batteries, thick film resistors, and temperature sensors; however, there are no reports on their application in electrochemical immunosensing. In this study, we exploited the (electro)catalytic nature and stability of the pyrochlore Bi2Ru2O7 clusters silanized with (3-aminopropyl)triethoxysilane (APTES) to demonstrate their potential for the effective stacking of functional proteins. Characterization of the clusters by XPS disclosed a dual environment of Bi, also indicating the presence of Bi2O3 alongside APTES-Bi2Ru2O7 clusters and, importantly, the predominant involvement of pyrochlore moieties in subsequent protein stacking. After stacking protein A and antibodies, the immunosensor revealed a nearly interference-free operation, high sensitivity, a detection limit of 118 fM SARS-CoV-2 spike protein, and operation in a wide examined concentration range of 10-5-10-1 μg mL-1 with an r2 of 0.98. In combination with a short incubation time of 30 min, the pyrochlore-based immunosensor provides a solid platform for future point-of-need applications.
- Open Access
- 4 January 2025
- Published by Elsevier in Electrochimica Acta
- Vol. 514
New electrochemical approach for assessing surface tension and its role in atmospheric particle growth
- 4 January 2025
- Published by Elsevier in Electrochimica Acta
- Vol. 514
Open AccessNew electrochemical approach for assessing surface tension and its role in atmospheric particle growth
- Open Access
- 30 May 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (23) , 30196-30208
Study of V2CTx-MXene Based Immunosensor for Sensitive Label-Free Impedimetric Detection of SARS-CoV-2 Spike Protein
Rapid and reliable immunosensing is undoubtedly one of the priorities in the efficient management and combat against a pandemic, as society has experienced with the SARS-CoV-2 outbreak; simple and cost-effective sensing strategies are at the forefront of these efforts. In this regard, 2D-layered MXenes hold great potential for electrochemical biosensing due to their attractive physicochemical properties. Herein, we present a V2CTx MXene-based sensing layer as an integral part of a label-free immunosensor for sensitive and selective detection of the SARS-CoV-2 spike protein. The sensor was fabricated on a supporting screen-printed carbon electrode using Nafion as an immobilizing agent for MXene and glutaraldehyde, the latter enabling effective binding of protein A for further site-oriented immobilization of anti-SARS-CoV-2 antibodies. A thorough structural analysis of the sensor architecture was carried out, and several key parameters affecting the fabrication and analytical performance of the immunosensor were investigated and optimized. The immunosensor showed excellent electroanalytical performance in combination with an impedimetric approach and exhibited a low detection limit of only 45 fM SARS-CoV-2 spike protein. Its practical applicability was successfully demonstrated by measuring the spike protein in a spiked artificial nasopharyngeal fluid sample.
- 30 May 2024
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 16 (23) , 30196-30208
Open AccessStudy of V2CTx-MXene Based Immunosensor for Sensitive Label-Free Impedimetric Detection of SARS-CoV-2 Spike Protein
Rapid and reliable immunosensing is undoubtedly one of the priorities in the efficient management and combat against a pandemic, as society has experienced with the SARS-CoV-2 outbreak; simple and cost-effective sensing strategies are at the forefront of these efforts. In this regard, 2D-layered MXenes hold great potential for electrochemical biosensing due to their attractive physicochemical properties. Herein, we present a V2CTx MXene-based sensing layer as an integral part of a label-free immunosensor for sensitive and selective detection of the SARS-CoV-2 spike protein. The sensor was fabricated on a supporting screen-printed carbon electrode using Nafion as an immobilizing agent for MXene and glutaraldehyde, the latter enabling effective binding of protein A for further site-oriented immobilization of anti-SARS-CoV-2 antibodies. A thorough structural analysis of the sensor architecture was carried out, and several key parameters affecting the fabrication and analytical performance of the immunosensor were investigated and optimized. The immunosensor showed excellent electroanalytical performance in combination with an impedimetric approach and exhibited a low detection limit of only 45 fM SARS-CoV-2 spike protein. Its practical applicability was successfully demonstrated by measuring the spike protein in a spiked artificial nasopharyngeal fluid sample.
- Open Access
- 3 August 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (32) , 39025
Correction to “Study of Chitosan-Stabilized Ti3C2Tx MXene for Ultrasensitive and Interference-Free Detection of Gaseous H2O2”
- 3 August 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (32) , 39025
Open AccessCorrection to “Study of Chitosan-Stabilized Ti3C2Tx MXene for Ultrasensitive and Interference-Free Detection of Gaseous H2O2”
- Open Access
- 3 July 2023
- Published by Elsevier in Electrochimica Acta
- Vol. 463
Development of a simple gelatin-based sensing platform for the sensitive label-free impedimetric detection of SARS-CoV-2
- 3 July 2023
- Published by Elsevier in Electrochimica Acta
- Vol. 463
Open AccessDevelopment of a simple gelatin-based sensing platform for the sensitive label-free impedimetric detection of SARS-CoV-2
- Open Access
- 23 June 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (26) , 31643-31651
Study of Chitosan-Stabilized Ti3C2Tx MXene for Ultrasensitive and Interference-Free Detection of Gaseous H2O2
The development of sensitive, selective, and reliable gaseous hydrogen peroxide (H2O2) sensors operating at room temperature still represents a remaining challenge. In this work, we have investigated and combined the advantageous properties of a two-dimensional Ti3C2Tx MXene material that exhibits a large specific surface area and high surface activity, with favorable conducting and stabilizing properties of chitosan. The MXene-chitosan membrane was deposited on the ferrocyanide-modified screen-printed working carbon electrode, followed by applying poly(acrylic acid) as an electrolyte and accumulation medium for gaseous H2O2. The sensor showed highly sensitive and selective electroanalytical performance for detecting trace concentrations of gaseous H2O2 with a very low detection limit of 4 μg m-3 (4 ppbv), linear response in the studied concentration range of 0.5-30.0 mg m-3, and good reproducibility with an RSD of 1.3%. The applicability of the sensor was demonstrated by point-of-interest detection of gaseous H2O2 during the real hair bleaching process with a 9 and 12% H2O2 solution.
- 23 June 2023
- Published by American Chemical Society (ACS) in ACS Applied Materials & Interfaces
- Vol. 15 (26) , 31643-31651
Open AccessStudy of Chitosan-Stabilized Ti3C2Tx MXene for Ultrasensitive and Interference-Free Detection of Gaseous H2O2
The development of sensitive, selective, and reliable gaseous hydrogen peroxide (H2O2) sensors operating at room temperature still represents a remaining challenge. In this work, we have investigated and combined the advantageous properties of a two-dimensional Ti3C2Tx MXene material that exhibits a large specific surface area and high surface activity, with favorable conducting and stabilizing properties of chitosan. The MXene-chitosan membrane was deposited on the ferrocyanide-modified screen-printed working carbon electrode, followed by applying poly(acrylic acid) as an electrolyte and accumulation medium for gaseous H2O2. The sensor showed highly sensitive and selective electroanalytical performance for detecting trace concentrations of gaseous H2O2 with a very low detection limit of 4 μg m-3 (4 ppbv), linear response in the studied concentration range of 0.5-30.0 mg m-3, and good reproducibility with an RSD of 1.3%. The applicability of the sensor was demonstrated by point-of-interest detection of gaseous H2O2 during the real hair bleaching process with a 9 and 12% H2O2 solution.
- Open Access
- 26 April 2023
- Published by Elsevier in Electrochimica Acta
- Vol. 457
Study of different types of copper electrodes for anodic stripping voltammetric detection of trace metal ions
- 26 April 2023
- Published by Elsevier in Electrochimica Acta
- Vol. 457
Open AccessStudy of different types of copper electrodes for anodic stripping voltammetric detection of trace metal ions