Tim Boretius
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Tim Boretius has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Thomas Stieglitz
Laboratory for Biomedical Microtechnology, IMTEK, University of Freiburg
5 shared publications Christina Hassler
Laboratory for Biomedical Microtechnology, Department of Microsystems Engineering-IMTEK, University of Freiburg, Georges-Koehler-Allee 102, Freiburg, Germany
2 shared publications- Christian Boehler
Intelligent Machine‐Brain Interfacing Technology (IMBIT) University of Freiburg Freiburg Germany
1 shared publication Christian Koehler
Laboratory of MEMS Applications, Department of Microsystems Engineering-IMTEK, University of Freiburg, Freiburg, Germany
1 shared publicationHarald Hillebrecht
Laboratory for Solid State Chemistry, Department of Anorganic Chemistry, University of Freiburg, Freiburg, Germany
1 shared publication- Juan S. Ordonez
Laboratory for Biomedical Microtechnology, Dept. of Microsystems Engineering-IMTEK, Univ. of Freiburg, Germany
1 shared publication
Latest Publications
- 8 June 2012
- Published by Springer Nature in MRS Bulletin
- Vol. 37 (6) , 590-598
Thin films and microelectrode arrays for neuroprosthetics
- 8 June 2012
- Published by Springer Nature in MRS Bulletin
- Vol. 37 (6) , 590-598
Thin films and microelectrode arrays for neuroprosthetics
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2011 (1094687X) , 5404-5407
High-porous platinum electrodes for functional electrical stimulation
This paper reports on the preparation and characterization of highly porous platinum electrodes for functional electrical stimulation. Thin-film platinum electrodes were roughened by electrochemical deposition of platinum-copper alloys and subsequent removal of copper using cyclic voltammetry (CV). Prepared samples were characterized by electrochemical impedance spectroscopies (EIS), CVs and long-term pulse testing. The electrodes exhibited an increased porosity by a factor of ~238 when compared to sputtered platinum electrodes. EIS measurements showed a decreased impedance of about 85% and pulse tests suggested a stable coating over at least 250 million pulses.
- 1 August 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2011 (1094687X) , 5404-5407
High-porous platinum electrodes for functional electrical stimulation
This paper reports on the preparation and characterization of highly porous platinum electrodes for functional electrical stimulation. Thin-film platinum electrodes were roughened by electrochemical deposition of platinum-copper alloys and subsequent removal of copper using cyclic voltammetry (CV). Prepared samples were characterized by electrochemical impedance spectroscopies (EIS), CVs and long-term pulse testing. The electrodes exhibited an increased porosity by a factor of ~238 when compared to sputtered platinum electrodes. EIS measurements showed a decreased impedance of about 85% and pulse tests suggested a stable coating over at least 250 million pulses.
- 15 March 2011
- Published by Wiley in Artificial Organs
- Vol. 35 (3) , 245-248
On the Stability of Poly‐Ethylenedioxythiopene as Coating Material for Active Neural Implants
This article deals with the stability of poly‐ethylenedioxythiopene (PEDOT) coatings under high loads of current pulses. Test parameters were chosen to match many peripheral nervous system applications in regard of charge injection, pulse width, and repetition frequency. PEDOT coatings were characterized with electrochemical impedance spectroscopes and pulse tests. After 60–100 million pulses, impedance increased and a more capacitive behavior was observed. A mean‐time‐to‐failure of 127 million pulses could be calculated, suggesting a stable coating for at least this time frame with superior properties in regard of conventional platinum electrodes.
- 15 March 2011
- Published by Wiley in Artificial Organs
- Vol. 35 (3) , 245-248
On the Stability of Poly‐Ethylenedioxythiopene as Coating Material for Active Neural Implants
This article deals with the stability of poly‐ethylenedioxythiopene (PEDOT) coatings under high loads of current pulses. Test parameters were chosen to match many peripheral nervous system applications in regard of charge injection, pulse width, and repetition frequency. PEDOT coatings were characterized with electrochemical impedance spectroscopes and pulse tests. After 60–100 million pulses, impedance increased and a more capacitive behavior was observed. A mean‐time‐to‐failure of 127 million pulses could be calculated, suggesting a stable coating for at least this time frame with superior properties in regard of conventional platinum electrodes.
- Open Access
- 30 December 2010
- Published by Wiley in Journal of Polymer Science Part B: Polymer Physics
- Vol. 49 (3) , 255
Erratum: Polymers for neural implants
- 30 December 2010
- Published by Wiley in Journal of Polymer Science Part B: Polymer Physics
- Vol. 49 (3) , 255
Open AccessErratum: Polymers for neural implants
- Top Cited PapersOpen Access
- 23 November 2010
- Published by Wiley in Journal of Polymer Science Part B: Polymer Physics
- Vol. 49 (1) , 18-33
Polymers for neural implants
Neural implants are technical systems that restore sensory or motor functions after injury and modulate neural behavior in neuronal diseases. Neural interfaces or prostheses have lead to new therapeutic options and rehabilitation approaches in the last 40 years. The interface between the nervous tissue and the technical material is the place that determines success or failure of the neural implant. Recording of nerve signals and stimulation of nerve cells take place at this neuro‐technical interface. Polymers are the most common material class for substrate and insulation materials in combination with metals for interconnection wires and electrode sites. This work focuses on the neuro‐technical interface and summarizes its fundamental specifications first. The most common polymer materials are presented and described in detail. We conclude with an overview of the different applications and their specific designs with the accompanying manufacturing processes from precision mechanics, laser structuring and micromachining that are introduced in either the peripheral or central nervous system. © 2010 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys, 2010
- 23 November 2010
- Published by Wiley in Journal of Polymer Science Part B: Polymer Physics
- Vol. 49 (1) , 18-33
Top Cited PapersOpen AccessPolymers for neural implants
Neural implants are technical systems that restore sensory or motor functions after injury and modulate neural behavior in neuronal diseases. Neural interfaces or prostheses have lead to new therapeutic options and rehabilitation approaches in the last 40 years. The interface between the nervous tissue and the technical material is the place that determines success or failure of the neural implant. Recording of nerve signals and stimulation of nerve cells take place at this neuro‐technical interface. Polymers are the most common material class for substrate and insulation materials in combination with metals for interconnection wires and electrode sites. This work focuses on the neuro‐technical interface and summarizes its fundamental specifications first. The most common polymer materials are presented and described in detail. We conclude with an overview of the different applications and their specific designs with the accompanying manufacturing processes from precision mechanics, laser structuring and micromachining that are introduced in either the peripheral or central nervous system. © 2010 Wiley Periodicals, Inc. J Polym Sci Part B: Polym Phys, 2010