TUTorsten Ueberrueck

Torsten Ueberrueck

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Torsten Ueberrueck has a total of 20 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Endovaskuläre Aneurysmaausschaltung nach aortofemoraler Homograftimplantation

    by T. Überrück, J. Zanow, F. Rauchfuß, U. Settmacher

    Fallbeispiel: Es wird über die endovaskuläre Behandlung von 2 Patienten berichtet, denen zuvor eine aortobifemorale Prothese aufgrund einer Spätinfektion explantiert wurde. Die Rekonstruktion erfolgte aortofemoral links durch einen Homograft und rechts durch einen Venenbypass bzw. eine langstreckige Desobliteration der Beckenarterie. Nach 4 bzw. 10 Monaten stellte sich in der Angio-CT ein Aneurysma spurium der Homografts im aortalen Anastomosenbereich dar. Zur Ausschaltung beider Aneurysmen wurde ein uniiliakales Stentgraft-System in Kombination mit einem femoro-femoralen Bypass zur Revaskularisierung des kontralateralen Beines verwendet. Beide Operationen verliefen zunächst erfolgreich, jedoch entwickelte ein Patient eine Infektion des Stentgrafts mit notwendiger Explantation und Rekonstruktion durch einen erneuten Homograftbypass. Schlussfolgerungen: Beide aneurysmatischen Komplikationen nach aortofemoraler Homograftimplantation ließen sich endovaskulär behandeln. Spätkomplikationen nach Homograftimplantationen und endovaskulärer Aneurysmaausschaltung können nur durch eine engmaschige Verlaufskontrolle rechtzeitig entdeckt werden. Case Report: We report on two rare endovascular procedures concerning aneurysmatic complications of arterial homografts. In both cases infected aortobifemoral grafts were explanted und replaced by cryopreserved aortofemoral homografts on the left side. The revascularisations on the right side were performed with the deep femoral vein in one case, and by desobliteration of the iliac artery in the other case. After 4 and 10 months, respectively, we found aneurysmatic enlargements of the aortic anastomoses. In both cases we excluded a false aortic aneurysm by uniiliac stentgrafts in combination with a femoro-femoral cross-over bypass for the contralateral leg. Both operations were carried out successfully. However, one patient developed an infection of the stent graft. We explanted the stent graft und performed an aortobifemoral bypass procedure with arterial cryopreserved homograft once again. Conclusions: Both aneurysmatic complications after aortofemoral homograft implantation could be treated successfully by an endovascular approach. Possible late complications caused by the implantation of homografts or by endovascular procedures can be only detected in due time by a follow-up at short intervals.

    • 1 April 2007
      • Vol. 48  (2) , 181-6

    Risk factors and management of arterial emboli of the upper and lower extremities.

    by T Ueberrueck, F Marusch, H Schmidt, I Gastinger

    Analysis of risk factors for the outcome of arterial embolism of the extremities (EE). Between 1999 and 2003, all patients (n=200) with an EE diagnosed in various departments of the hospital were recruited and analysed retrospectively (single center study). Exclusion criteria were isolated digital emboli, iatrogenic emboli and arterial thromboses. For statistical analysis was used the multivariate nominal regression. There were 138 (69%) leg, and 62 (31%) arm, emboli. Preoperative angiography was performed in 88 patients; a total of 119 (59.5%) cases of incomplete ischemia (leg n=69, arm n=50) were seen. The most common cause of the embolism (73%) was atrial fibrillation (AF). One hundred and seventhyt four patients (87%) were treated by primary surgery. The major amputation rate (lower limb) was 4.3%. Additional arterial emboli were seen in 14 (7%). The mortality rate was 13% (upper extremity embolism 4.8%; lower extremity embolism 16.7%; P=0.021). After discharge, 32.2% of the patients received oral anticoagulation, and 37.9% antiplatelet therapy. The statistical analysis identified postoperative cerebral/visceral thromboembolism as independent risk factor for mortality. The main risk factor for EE is AF. Hospital mortality is determined by comorbidity and cerebral or visceral embolism. For this reason, effective oral anticoagulation is required, but is possible in only one-third of the patients after discharge.

  • Vascular graft infections: In vitro and in vivo investigations of a new vascular graft with long‐term protection

    by Torsten Ueberrueck, Roland Zippel, Joerg Tautenhahn, Ingo Gastinger, Hans Lippert, Thorsten Wahlers

    We investigated a polyester vascular prosthesis (PET) coated with elemental silver (SC). Measurement of silver release over a period of 52 weeks by means of inductively coupled plasma atomic emission spectrometry of PET with (PET‐G) and without (PET‐N) gelatine impregnation revealed a silver release on the first day of 1.2 ± 0.2μg (PET‐N) and 1.2 ± 0.1 μg (PET‐G) (calculated for 1 g of prosthesis); from the 90th day onward, it was between 0.22 ± 0.14μg (PET‐N) and 0.18 ± 0.12 μg (PET‐G) per day. The prostheses were incubated with Staphylococcus aureus (S.a.), Staphylococcus epidermidis (S.e.), or Escherichia coli (E.c.) to investigate in vitro antibacterial efficacy. After 6 h of incubation, no colony‐forming units were to be seen for any of the bacterial suspensions for PET with SC (p < 0.001). To investigate in vivo antibacterial efficacy, PET‐G rings with and without SC contaminated with S.a., S.e., or E.c. were implanted in 18 albino rabbits and examined 7 days after agar culture for 48 h. The silver coating was associated with a significant reduction in bacterial growth (S.a., p = 0.001; S.e., p < 0.005; E.c., p < 0.001). The silver‐coated prosthesis, with and without gelatine impregnation, had a significantly antibacterial effect with continuous release of silver. © 2005 Wiley Periodicals, Inc. J Biomed Mater Res Part B: Appl Biomater, 2005


  • The Significance of Meckel’s Diverticulum in Appendicitis — A Retrospective Analysis of 233 Cases

    by Torsten Ueberrueck, Lutz Meyer, Andreas Koch, Michael Hinkel, Rainer Kube, Ingo Gastinger

    Conflicting reports are found in the literature concerning whether to remove an incidentally discovered Meckel’s diverticulum (MD). Between 1.1.1974 and 31.12.2000, at a single center, the perioperative data associated with appendectomy (AE) were recorded consecutively and analyzed retrospectively. All patients in whom an MD was discovered during an AE were included in the study. The clinical presentation, postoperative course, and follow‐up in all MDs left in place were analyzed. During the course of 7927 AE, 233 MD (2.9%) were detected. Of these 80.7% (n = 188) were removed and 19.3% (n = 45) were left untouched. In 9% (n = 21) of all detected diverticula pathological changes were found. Ectopic tissue was seen in 12.2% (n = 23) of the MDs removed. The postoperative complication rates did not differ significantly between patients in whom the MD was removed (9.5%; n = l8) and those in whom it was not (17.7%; n = 8); in the latter group the appendicitis was of the more acute type (gangrenous or perforated) (24.4% vs. 4.3%). In 18 patients (40.0%) with non‐removed MDs, a follow‐up period of 14.1 ± 5.8 years was achieved. Complications associated with a non‐removed MD were not observed. If during the course of an AE a MD is detected, the present data, as well as those in the literature, suggest that an individualized approach should be taken. Meckel’s diverticulum with obvious pathology should always be removed. In cases of gangrenous or perforated appendicitis, an incidentally discovered MD should be left in place, whereas in an only mildly inflamed appendix it should be removed.


  • Healing Characteristics of a New Silver-Coated, Gelatine Impregnated Vascular Prosthesis in the Porcine Model

    by T. Ueberrueck, L. Meyer, R. Zippel, G. Nestler, T. Wahlers, I. Gastinger

    Objectives: To investigate the intraluminal and extraluminal healing behaviour of a new metallic silver coated, gelatine impregnated vascular graft. Design: Comparative animal experimental investigation with randomisation of the animals to control and experimental groups. Material and Methods: 24 pigs were assigned to two control and two experimental groups. The prostheses were interposed in the pigs' infrarenal aorta. For the evaluation, macroscopic, histological and immunohistochemical criteria were applied. Results: The macroscopic evaluation after explantation of the prosthesis revealed similar healing characteristics in the control and experimental groups. The microscopic determination of neo-intimal thickness showed no significant differences between the groups; nor did the immunohistochemical investigations show any significant difference between the control group and the silver-coated prosthesis group. Conclusions: No disadvantage of the silver coating in terms of healing and graft patency was found. A possible advantage in terms of the antibacterial effect of the silver coating must be investigated in the clinical setting. Hintergrund: Untersuchung der intra- und extraluminalen Einheilung einer neuen metallisch Silber-beschichteten, Gelatine-imprägnierten Gefäßprothese. Design: Vergleichende tierexperimentelle Untersuchung mit Randomisierung in Kontroll- und Versuchsgruppen. Material und Methode: 24 Schweine wurden in 2 Kontroll- und 2 Versuchsgruppen randomisiert. Die Gefäßprothesen wurden in die infrarenale Aorta interponiert. Zur Auswertung wurden makroskopische, histologische und immunhistochemische Kriterien verwendet. Ergebnisse: Die makroskopische Beurteilung stellte nach Prothesenexplantation ein vergleichbares Einheilungsverhalten von Kontroll- und Versuchsgruppen dar. Die mikroskopische Neointimadickenbestimmung zeigte keine signifikanten Unterschiede zwischen den Gruppen. In den immunhistochemischen Untersuchungen waren ebenfalls keine signifikanten Unterschiede zwischen der Kontrollgruppe und den silberbeschichteten Gefäßprothesen nachweisbar. Schlussfolgerungen: Ein Nachteil durch die Silberbeschichtung in Bezug auf Einheilung und Offenheit konnte nicht nachgewiesen werden. Ein möglicher Vorteil durch die antibakterielle Wirkung der Silberbeschichtung muss in der klinischen Anwendung untersucht werden.