Vincent Bennani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Vincent Bennani has a total of 61 co-authors. Here are the top co-authors by number of shared publications:
- John M. Aarts
Senior Lecturer, Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
8 shared publications - Arthi Veerasamy
Senior Lecturer, Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
6 shared publications John M. Aarts
Senior Lecturer, Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
6 shared publications- Karl Lyons
Department of Oral Rehabilitation, Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin 9054, New Zealand
5 shared publications Nicholas Chandler
Department of Oral Rehabilitation, University of Otago Faculty of Dentistry, Dunedin, New Zealand
5 shared publications- Zijing He
PhD candidate, Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
5 shared publications
Latest Publications
- Open Access
- 17 September 2026
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 136 (5) , e39-e46
Comparison of trueness of cobalt chromium implant-supported frameworks fabricated using additive and subtractive manufacturing: An in vitro study
- 17 September 2026
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 136 (5) , e39-e46
Open AccessComparison of trueness of cobalt chromium implant-supported frameworks fabricated using additive and subtractive manufacturing: An in vitro study
- Open Access
- 4 September 2026
- Published by Wiley in Journal of Prosthodontics
Clinical implications of misfit in multiunit implant‐supported fixed dental prostheses: A systematic review
Purpose: This systematic review aimed to evaluate the long‐term effects of misfit on the clinical outcomes of multiunit implant‐supported fixed dental prostheses (ISFDPs). Methods: An electronic literature search was conducted up to December 2025 across five databases: MEDLINE (via Ovid), Embase (via Ovid), Web of Science, the Cochrane Library, and Scopus. Eligible articles were selected based on predefined inclusion and exclusion criteria, and relevant data were extracted. The Newcastle‐Ottawa Scale was used to evaluate the methodological quality of the included studies. Results: After screening and applying the eligibility criteria, four articles were identified from the initial 2179 records. Two additional articles were identified through a manual search, bringing the total to six. Although quality assessment indicated that all six studies were at low risk of bias, the comparability domain was weak in most due to limited control of confounding factors. Clinical outcomes in the included studies were reported across four domains: implant cumulative survival rate, screw loosening or fracture, prosthesis‐related complications, and peri‐implant bone loss. Only one study reported a significantly higher incidence of screw complications in ISFDPs with greater misfit ( p = 0.005), whereas most studies did not find a consistent association between misfit and clinical outcomes. Conclusions: Evidence regarding the clinical implications of misfit in multiunit ISFDPs is limited, with few long‐term studies and insufficient control for confounding factors. Limited evidence suggests that greater misfit may be associated with screw complications, whereas no clear association was observed between misfit and peri‐implant bone loss.
- 4 September 2026
- Published by Wiley in Journal of Prosthodontics
Open AccessClinical implications of misfit in multiunit implant‐supported fixed dental prostheses: A systematic review
Purpose: This systematic review aimed to evaluate the long‐term effects of misfit on the clinical outcomes of multiunit implant‐supported fixed dental prostheses (ISFDPs). Methods: An electronic literature search was conducted up to December 2025 across five databases: MEDLINE (via Ovid), Embase (via Ovid), Web of Science, the Cochrane Library, and Scopus. Eligible articles were selected based on predefined inclusion and exclusion criteria, and relevant data were extracted. The Newcastle‐Ottawa Scale was used to evaluate the methodological quality of the included studies. Results: After screening and applying the eligibility criteria, four articles were identified from the initial 2179 records. Two additional articles were identified through a manual search, bringing the total to six. Although quality assessment indicated that all six studies were at low risk of bias, the comparability domain was weak in most due to limited control of confounding factors. Clinical outcomes in the included studies were reported across four domains: implant cumulative survival rate, screw loosening or fracture, prosthesis‐related complications, and peri‐implant bone loss. Only one study reported a significantly higher incidence of screw complications in ISFDPs with greater misfit ( p = 0.005), whereas most studies did not find a consistent association between misfit and clinical outcomes. Conclusions: Evidence regarding the clinical implications of misfit in multiunit ISFDPs is limited, with few long‐term studies and insufficient control for confounding factors. Limited evidence suggests that greater misfit may be associated with screw complications, whereas no clear association was observed between misfit and peri‐implant bone loss.
- Open Access
- 1 January 2026
- Published by Wiley in International Journal of Dentistry
- Vol. 2026 (1) , 8282494
Survival and Complication Rates of Tooth‐Supported Veneered Zirconia Fixed Partial Dentures: A Systematic Review and Metaanalysis
Statement of Problem: The long‐term survival and complication rates of tooth‐supported veneered zirconia fixed partial dentures (FPDs) remain unclear due to heterogeneous and fragmented clinical evidence. Therefore, a systematic review and metaanalysis were conducted to synthesize the available clinical data. Purpose: The purpose of this systematic review and metaanalysis was to evaluate the survival rates and the incidence of technical and biological complications associated with tooth‐supported veneered zirconia FPDs. Materials and Methods: Electronic searches were conducted in MEDLINE/Embase, PubMed, Scopus, Web of Science, and Google Scholar databases up to August 2026 according to preferred reporting Items for systematic reviews and metaanalyses (PRISMA) guidelines. Clinical studies evaluating tooth‐supported veneered zirconia FPDs with a minimum follow‐up of 5 years were included. Randomized clinical trials and prospective or retrospective observational studies reporting survival or complication outcomes were considered. Risk of bias was assessed using the ROBINS‐I tool for cohort studies and the Joanna Briggs Institute (JBI) case series checklist for single‐arm studies. Metaanalysis was performed using R software (ggplot and meta package) with a random‐effects model. Results: The database search identified 2220 records. After removal of 1815 duplicates, 405 records were screened by title and A total of 180 full‐text articles were assessed for eligibility, and 17 studies met the inclusion criteria and were included in the quantitative synthesis. The pooled survival rate for veneered zirconia was 92% (95% CI: 90%–94%) at 5 years, 86% (95% CI: 81%–89%) at 7 years, and 83% (95% CI: 71%–91%) at 10 years. Veneered zirconia prostheses demonstrated higher technical complications, particularly veneering porcelain chipping. Conclusion: Tooth‐supported veneered zirconia fixed dental prostheses demonstrated acceptable survival rates over 5–13 years, with most studies reporting survival above 85%. The most frequent complications were chipping of the veneering porcelain. Clinical Implication: Understanding the survival and complication patterns of tooth‐supported veneered zirconia FPDs provides valuable insights for clinicians in selecting suitable restorative materials and prosthesis designs.
- 1 January 2026
- Published by Wiley in International Journal of Dentistry
- Vol. 2026 (1) , 8282494
Open AccessSurvival and Complication Rates of Tooth‐Supported Veneered Zirconia Fixed Partial Dentures: A Systematic Review and Metaanalysis
Statement of Problem: The long‐term survival and complication rates of tooth‐supported veneered zirconia fixed partial dentures (FPDs) remain unclear due to heterogeneous and fragmented clinical evidence. Therefore, a systematic review and metaanalysis were conducted to synthesize the available clinical data. Purpose: The purpose of this systematic review and metaanalysis was to evaluate the survival rates and the incidence of technical and biological complications associated with tooth‐supported veneered zirconia FPDs. Materials and Methods: Electronic searches were conducted in MEDLINE/Embase, PubMed, Scopus, Web of Science, and Google Scholar databases up to August 2026 according to preferred reporting Items for systematic reviews and metaanalyses (PRISMA) guidelines. Clinical studies evaluating tooth‐supported veneered zirconia FPDs with a minimum follow‐up of 5 years were included. Randomized clinical trials and prospective or retrospective observational studies reporting survival or complication outcomes were considered. Risk of bias was assessed using the ROBINS‐I tool for cohort studies and the Joanna Briggs Institute (JBI) case series checklist for single‐arm studies. Metaanalysis was performed using R software (ggplot and meta package) with a random‐effects model. Results: The database search identified 2220 records. After removal of 1815 duplicates, 405 records were screened by title and A total of 180 full‐text articles were assessed for eligibility, and 17 studies met the inclusion criteria and were included in the quantitative synthesis. The pooled survival rate for veneered zirconia was 92% (95% CI: 90%–94%) at 5 years, 86% (95% CI: 81%–89%) at 7 years, and 83% (95% CI: 71%–91%) at 10 years. Veneered zirconia prostheses demonstrated higher technical complications, particularly veneering porcelain chipping. Conclusion: Tooth‐supported veneered zirconia fixed dental prostheses demonstrated acceptable survival rates over 5–13 years, with most studies reporting survival above 85%. The most frequent complications were chipping of the veneering porcelain. Clinical Implication: Understanding the survival and complication patterns of tooth‐supported veneered zirconia FPDs provides valuable insights for clinicians in selecting suitable restorative materials and prosthesis designs.
- Open Access
- 1 January 2026
- Published by Wiley in International Journal of Dentistry
- Vol. 2026 (1) , 4948410
Key Factors Influencing the Adoption of CAD/CAM in the Fabrication of Indirect Dental Restorations
Introduction: Over recent decades, CAD/CAM (computer assisted design/computer assisted manufacture) has become increasingly prevalent in dentistry. These systems offer alternatives to various stages of the conventional workflow for indirect restorations. While CAD/CAM has been explored in previous studies, their use in New Zealand (NZ) remains under‐researched. This study aimed to assess the prevalence of CAD/CAM usage and identify factors influencing their adoption among dentists and dental technicians. Methods: Questionnaires adapted from previous research were distributed to 1703 registered dentists and 198 dental technicians via the DCNZ registry. Responses were analysed descriptively, with chi‐square and Fisher’s exact tests used to examine associations. Results: A total of 332 dentists responded (19% response rate) and 40 dental technicians responded. CAD/CAM was used by 59% of dentists and 87% of technicians for indirect restorations. Intraoral scanning and chairside systems were the most common applications, used by 93% and 66% of CAD/CAM users, respectively. Key barriers included cost and lack of training; primary facilitators were increased efficiency and staying current with technology. Gender, practice typeand volume of restorations were significantly associated with adoption among dentists. Conclusion: This study’s findings highlight the growing prominence of CAD/CAM in dentistry, with dental technicians adopting them more rapidly than dentists. To close this gap, enhancements in dental education and targeted training programmes are crucial for supporting and accelerating the integration of digital workflows into clinical practice.
- 1 January 2026
- Published by Wiley in International Journal of Dentistry
- Vol. 2026 (1) , 4948410
Open AccessKey Factors Influencing the Adoption of CAD/CAM in the Fabrication of Indirect Dental Restorations
Introduction: Over recent decades, CAD/CAM (computer assisted design/computer assisted manufacture) has become increasingly prevalent in dentistry. These systems offer alternatives to various stages of the conventional workflow for indirect restorations. While CAD/CAM has been explored in previous studies, their use in New Zealand (NZ) remains under‐researched. This study aimed to assess the prevalence of CAD/CAM usage and identify factors influencing their adoption among dentists and dental technicians. Methods: Questionnaires adapted from previous research were distributed to 1703 registered dentists and 198 dental technicians via the DCNZ registry. Responses were analysed descriptively, with chi‐square and Fisher’s exact tests used to examine associations. Results: A total of 332 dentists responded (19% response rate) and 40 dental technicians responded. CAD/CAM was used by 59% of dentists and 87% of technicians for indirect restorations. Intraoral scanning and chairside systems were the most common applications, used by 93% and 66% of CAD/CAM users, respectively. Key barriers included cost and lack of training; primary facilitators were increased efficiency and staying current with technology. Gender, practice typeand volume of restorations were significantly associated with adoption among dentists. Conclusion: This study’s findings highlight the growing prominence of CAD/CAM in dentistry, with dental technicians adopting them more rapidly than dentists. To close this gap, enhancements in dental education and targeted training programmes are crucial for supporting and accelerating the integration of digital workflows into clinical practice.
- Open Access
- 29 November 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (4) , 753.e1-753.e11
Precision of measurement methods for assessing the fit of screw-retained implant-supported fixed partial dentures: A systematic review of in vitro studies
- 29 November 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (4) , 753.e1-753.e11
Open AccessPrecision of measurement methods for assessing the fit of screw-retained implant-supported fixed partial dentures: A systematic review of in vitro studies
- Open Access
- 11 September 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (1) , 64.e1-64.e10
Fit accuracy of 3D printed Co-Cr multiunit implant-supported fixed dental prostheses: A systematic review of in vitro studies
- 11 September 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (1) , 64.e1-64.e10
Open AccessFit accuracy of 3D printed Co-Cr multiunit implant-supported fixed dental prostheses: A systematic review of in vitro studies
- Open Access
- 17 May 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 134 (3) , 616-627
Influence of tooth preparation design on margin discrepancy and internal gap in digitally fabricated fixed complete coverage zirconia prostheses: A systematic review of in vitro studies
- 17 May 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 134 (3) , 616-627
Open AccessInfluence of tooth preparation design on margin discrepancy and internal gap in digitally fabricated fixed complete coverage zirconia prostheses: A systematic review of in vitro studies
- Open Access
- 1 January 2025
- Published by Wiley in International Journal of Dentistry
- Vol. 2025 (1)
Effect of a Modified Preparation Design on the Marginal and Internal Fit of 3D‐Printed Onlays: A Feasibility Study
Objective: Bonded onlay preparations provide minimal guidance during cementation, which may compromise seating accuracy and increase marginal and internal discrepancies, potentially affecting restoration longevity. This study aims to assess whether a modified preparation (MP) design improves onlay positioning during cementation to enhance marginal and internal fit. Materials and Methods: The conventional preparation (CP) design was prepared on a typodont tooth, scanned, and replicated ( n = 20). A cross‐shaped groove was added to the prepared typodont tooth to create the MP design, then scanned and replicated ( n = 20). For both groups, a restoration was designed using computer‐aided design (CAD) and computer‐aided manufacturing (CAM). Each onlay was three‐dimensionally (3D) printed, assessed for fit, and then bonded onto the replicas. Ten specimens from each group were sectioned horizontally and 10 vertically. Absolute marginal discrepancy (AMD) and internal cement thickness (ICT) were measured on the horizontally and vertically sectioned specimens under a stereomicroscope. Data were analyzed using the Mann–Whitney U test ( α = 0.05). Results: The MP showed a statistically significant lower mean AMD than the CP at the palatal ( p = 0.035) and buccal ( p = 0.006) sites. However, there was no statistically significant difference at the mesial site ( p = 0.193). The CP had a statistically significant lower ICT than the MP in the vertical section ( p = 0.009), but the difference in the horizontal section was not statistically significant ( p = 0.121). Conclusions: The MP improved AMD compared to the CP at buccal and palatal sites, but increased ICT in the vertical section. Clinical Significance: The MP design showed that a minor modification to the conventional bonded onlay preparation design improved AMD but increased ICT. These findings guide clinicians in selecting optimal designs to improve restoration adaptation and longevity.
- 1 January 2025
- Published by Wiley in International Journal of Dentistry
- Vol. 2025 (1)
Open AccessEffect of a Modified Preparation Design on the Marginal and Internal Fit of 3D‐Printed Onlays: A Feasibility Study
Objective: Bonded onlay preparations provide minimal guidance during cementation, which may compromise seating accuracy and increase marginal and internal discrepancies, potentially affecting restoration longevity. This study aims to assess whether a modified preparation (MP) design improves onlay positioning during cementation to enhance marginal and internal fit. Materials and Methods: The conventional preparation (CP) design was prepared on a typodont tooth, scanned, and replicated ( n = 20). A cross‐shaped groove was added to the prepared typodont tooth to create the MP design, then scanned and replicated ( n = 20). For both groups, a restoration was designed using computer‐aided design (CAD) and computer‐aided manufacturing (CAM). Each onlay was three‐dimensionally (3D) printed, assessed for fit, and then bonded onto the replicas. Ten specimens from each group were sectioned horizontally and 10 vertically. Absolute marginal discrepancy (AMD) and internal cement thickness (ICT) were measured on the horizontally and vertically sectioned specimens under a stereomicroscope. Data were analyzed using the Mann–Whitney U test ( α = 0.05). Results: The MP showed a statistically significant lower mean AMD than the CP at the palatal ( p = 0.035) and buccal ( p = 0.006) sites. However, there was no statistically significant difference at the mesial site ( p = 0.193). The CP had a statistically significant lower ICT than the MP in the vertical section ( p = 0.009), but the difference in the horizontal section was not statistically significant ( p = 0.121). Conclusions: The MP improved AMD compared to the CP at buccal and palatal sites, but increased ICT in the vertical section. Clinical Significance: The MP design showed that a minor modification to the conventional bonded onlay preparation design improved AMD but increased ICT. These findings guide clinicians in selecting optimal designs to improve restoration adaptation and longevity.
- Open Access
- 1 December 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 131 (2) , 252.e1-252.e8
Effect of a modified laminate veneer preparation design on absolute margin discrepancy and marginal overhang
- 1 December 2023
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 131 (2) , 252.e1-252.e8
Open AccessEffect of a modified laminate veneer preparation design on absolute margin discrepancy and marginal overhang