John M. Aarts
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
John M. Aarts has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Joanne Jung Eun Choi
Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
14 shared publications - Vincent Bennani
Associate Professor, Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
8 shared publications - Andrew B. Cameron
School of Medicine and Dentistry, Griffith University, Gold Coast, QLD 4215, Australia
6 shared publications - Paul Anthony Brunton
Curtin University, Bentley, WA 6102, Australia
4 shared publications Joanne Jung Eun Choi
Associate Professor, Department of Oral Rehabilitation, Faculty of Dentistry, University of Otago, Dunedin, New Zealand
3 shared publications- Nicholas C. K. Heng
Sir John Walsh Research Institute, Faculty of Dentistry, University of Otago, Dunedin 9054, New Zealand
3 shared publications
Latest Publications
- Open Access
- 17 September 2026
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 136 (5) , e39-e46
Comparison of trueness of cobalt chromium implant-supported frameworks fabricated using additive and subtractive manufacturing: An in vitro study
- 17 September 2026
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 136 (5) , e39-e46
Open AccessComparison of trueness of cobalt chromium implant-supported frameworks fabricated using additive and subtractive manufacturing: An in vitro study
- Open Access
- 4 September 2026
- Published by Wiley in Journal of Prosthodontics
Clinical implications of misfit in multiunit implant‐supported fixed dental prostheses: A systematic review
Purpose: This systematic review aimed to evaluate the long‐term effects of misfit on the clinical outcomes of multiunit implant‐supported fixed dental prostheses (ISFDPs). Methods: An electronic literature search was conducted up to December 2025 across five databases: MEDLINE (via Ovid), Embase (via Ovid), Web of Science, the Cochrane Library, and Scopus. Eligible articles were selected based on predefined inclusion and exclusion criteria, and relevant data were extracted. The Newcastle‐Ottawa Scale was used to evaluate the methodological quality of the included studies. Results: After screening and applying the eligibility criteria, four articles were identified from the initial 2179 records. Two additional articles were identified through a manual search, bringing the total to six. Although quality assessment indicated that all six studies were at low risk of bias, the comparability domain was weak in most due to limited control of confounding factors. Clinical outcomes in the included studies were reported across four domains: implant cumulative survival rate, screw loosening or fracture, prosthesis‐related complications, and peri‐implant bone loss. Only one study reported a significantly higher incidence of screw complications in ISFDPs with greater misfit ( p = 0.005), whereas most studies did not find a consistent association between misfit and clinical outcomes. Conclusions: Evidence regarding the clinical implications of misfit in multiunit ISFDPs is limited, with few long‐term studies and insufficient control for confounding factors. Limited evidence suggests that greater misfit may be associated with screw complications, whereas no clear association was observed between misfit and peri‐implant bone loss.
- 4 September 2026
- Published by Wiley in Journal of Prosthodontics
Open AccessClinical implications of misfit in multiunit implant‐supported fixed dental prostheses: A systematic review
Purpose: This systematic review aimed to evaluate the long‐term effects of misfit on the clinical outcomes of multiunit implant‐supported fixed dental prostheses (ISFDPs). Methods: An electronic literature search was conducted up to December 2025 across five databases: MEDLINE (via Ovid), Embase (via Ovid), Web of Science, the Cochrane Library, and Scopus. Eligible articles were selected based on predefined inclusion and exclusion criteria, and relevant data were extracted. The Newcastle‐Ottawa Scale was used to evaluate the methodological quality of the included studies. Results: After screening and applying the eligibility criteria, four articles were identified from the initial 2179 records. Two additional articles were identified through a manual search, bringing the total to six. Although quality assessment indicated that all six studies were at low risk of bias, the comparability domain was weak in most due to limited control of confounding factors. Clinical outcomes in the included studies were reported across four domains: implant cumulative survival rate, screw loosening or fracture, prosthesis‐related complications, and peri‐implant bone loss. Only one study reported a significantly higher incidence of screw complications in ISFDPs with greater misfit ( p = 0.005), whereas most studies did not find a consistent association between misfit and clinical outcomes. Conclusions: Evidence regarding the clinical implications of misfit in multiunit ISFDPs is limited, with few long‐term studies and insufficient control for confounding factors. Limited evidence suggests that greater misfit may be associated with screw complications, whereas no clear association was observed between misfit and peri‐implant bone loss.
- Open Access
- 20 August 2026
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 136 (4) , 1032-1048
Experimental approaches for evaluating the fracture resistance of removable complete dentures: A systematic review of in vitro studies
- 20 August 2026
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 136 (4) , 1032-1048
Open AccessExperimental approaches for evaluating the fracture resistance of removable complete dentures: A systematic review of in vitro studies
- Open Access
- 8 April 2026
- Published by Elsevier in Digital Dentistry Journal
- Vol. 4 (1)
Engineered micro-textures enhance adhesion in additively manufactured dental crowns
- 8 April 2026
- Published by Elsevier in Digital Dentistry Journal
- Vol. 4 (1)
Open AccessEngineered micro-textures enhance adhesion in additively manufactured dental crowns
- Open Access
- 25 December 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 165, 106315
Influence of different post-washing parameters on the properties of additively-manufactured dental devices - A systematic review
- 25 December 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 165, 106315
Open AccessInfluence of different post-washing parameters on the properties of additively-manufactured dental devices - A systematic review
- Open Access
- 16 September 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 162, 106110
Occlusal accuracy of digitally manufactured removable dentures: a systematic review of in vitro studies
- 16 September 2025
- Published by Elsevier in Journal of Dentistry
- Vol. 162, 106110
Open AccessOcclusal accuracy of digitally manufactured removable dentures: a systematic review of in vitro studies
- Open Access
- 11 September 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (1) , 64.e1-64.e10
Fit accuracy of 3D printed Co-Cr multiunit implant-supported fixed dental prostheses: A systematic review of in vitro studies
- 11 September 2025
- Published by Elsevier in The Journal of Prosthetic Dentistry
- Vol. 135 (1) , 64.e1-64.e10
Open AccessFit accuracy of 3D printed Co-Cr multiunit implant-supported fixed dental prostheses: A systematic review of in vitro studies
- Open Access
Bond Strength of Impression Materials to Conventional and Additively Manufactured Custom Tray Materials: A Systematic Review
Purpose: We aimed to systematically review the current literature on the bond strength between custom tray materials and impression materials, including the various parameters affecting the strength. Methods: Four electronic databases were used: Ovid, Web of Science, PubMed, and Scopus. Relevant studies were chosen based on their eligibility, determined through inclusion and exclusion criteria. This review followed the PRISMA strategy. A risk of bias assessment was produced to evaluate the validity of each study. Results: There were 173 initial relevant studies identified, and after the screening process, this was reduced to seven. Two additional studies were also included from hand searching, resulting in total nine studies to be included in the review. Four of the nine evaluated studies concerned additively manufactured (AM) materials, including acrylonitrile butadiene styrene (ABS), polyethylene terephthalate glycol polyester (PETG), high-impact polystyrene (HIPS), and polylactic acid (PLA). Five studies evaluated an auto-polymerizing resin and one a thermoplastic material. All studies used polyvinyl siloxane impression materials and an adhesive selection following manufacturers’ recommendations. Three studies used scanning electron microscopy (SEM) to analyze their specimens. All studies reported a low risk of bias. Conclusions: Surface roughening was shown to reduce the strength of the bonding interface, whereas combining chemical and mechanical retention was shown to increase the bond strength. Inconsistent results exist in determining if AMed (3D-printed) tray materials are comparable or perform better than the conventional tray materials, highlighting the need for further study. Clinical Significance: The bond strength of the custom tray to the dental impression material is critical as it affects the model produced and therefore the final prosthesis. It is therefore invaluable to use materials with high bond strength for the construction of custom trays.
Open AccessBond Strength of Impression Materials to Conventional and Additively Manufactured Custom Tray Materials: A Systematic Review
Purpose: We aimed to systematically review the current literature on the bond strength between custom tray materials and impression materials, including the various parameters affecting the strength. Methods: Four electronic databases were used: Ovid, Web of Science, PubMed, and Scopus. Relevant studies were chosen based on their eligibility, determined through inclusion and exclusion criteria. This review followed the PRISMA strategy. A risk of bias assessment was produced to evaluate the validity of each study. Results: There were 173 initial relevant studies identified, and after the screening process, this was reduced to seven. Two additional studies were also included from hand searching, resulting in total nine studies to be included in the review. Four of the nine evaluated studies concerned additively manufactured (AM) materials, including acrylonitrile butadiene styrene (ABS), polyethylene terephthalate glycol polyester (PETG), high-impact polystyrene (HIPS), and polylactic acid (PLA). Five studies evaluated an auto-polymerizing resin and one a thermoplastic material. All studies used polyvinyl siloxane impression materials and an adhesive selection following manufacturers’ recommendations. Three studies used scanning electron microscopy (SEM) to analyze their specimens. All studies reported a low risk of bias. Conclusions: Surface roughening was shown to reduce the strength of the bonding interface, whereas combining chemical and mechanical retention was shown to increase the bond strength. Inconsistent results exist in determining if AMed (3D-printed) tray materials are comparable or perform better than the conventional tray materials, highlighting the need for further study. Clinical Significance: The bond strength of the custom tray to the dental impression material is critical as it affects the model produced and therefore the final prosthesis. It is therefore invaluable to use materials with high bond strength for the construction of custom trays.
- Open Access
- 28 March 2025
- Published by MDPI AG in Journal of Manufacturing and Materials Processing
- Vol. 9 (4) , 113
Mechanical Properties and Accuracy of Additively Manufactured Silicone Soft Tissue Materials
The objective of this study was to measure and compare the mechanical properties of conventional and three additively manufactured soft tissue silicone materials, while evaluating the precision of additively manufactured (AMed) materials through different printing angles. Three additively manufactured soft tissue silicone materials were used, in addition to one conventional self-curing injectable silicone material as a control. AMed materials were divided into three groups with three build angles. Mechanical testing was conducted for tensile and compressive strength by a universal testing machine and Shore A hardness by a durometer. Accuracy analysis of additively manufactured materials (n = 20/group) was performed following superimposition and root mean square (RMS) calculation. Statistical differences between the groups were assessed with a one-way analysis of variance (ANOVA) and Tukey’s post hoc test at a significance level of p < 0.05. Scanning Electron Microscopy (SEM) analysis was performed for fracture surface analyses. The tensile strength of all additively manufactured silicone soft tissue materials was significantly lower (p < 0.0001) than that of the control material. All additively manufactured soft tissue material groups had significantly higher compressive strengths (p < 0.0001) and Shore A hardness values. Accuracy analysis showed no significant difference between the groups when compared at the same printing angle (0°, 45°, and 90°); however, within each material group, printing at 45° had higher RMS values than specimens printed at an angle of 0° and 90°. The conventional soft tissue material (control) had a significantly higher tensile strength than all the AMed soft tissue materials, whereas the opposite trend was found for flexural strength and shore hardness. When selecting an AMed material for soft tissue casts used during implant restoration fabrication, it is recommended to print the soft tissues at either 0° or 90°.
- 28 March 2025
- Published by MDPI AG in Journal of Manufacturing and Materials Processing
- Vol. 9 (4) , 113
Open AccessMechanical Properties and Accuracy of Additively Manufactured Silicone Soft Tissue Materials
The objective of this study was to measure and compare the mechanical properties of conventional and three additively manufactured soft tissue silicone materials, while evaluating the precision of additively manufactured (AMed) materials through different printing angles. Three additively manufactured soft tissue silicone materials were used, in addition to one conventional self-curing injectable silicone material as a control. AMed materials were divided into three groups with three build angles. Mechanical testing was conducted for tensile and compressive strength by a universal testing machine and Shore A hardness by a durometer. Accuracy analysis of additively manufactured materials (n = 20/group) was performed following superimposition and root mean square (RMS) calculation. Statistical differences between the groups were assessed with a one-way analysis of variance (ANOVA) and Tukey’s post hoc test at a significance level of p < 0.05. Scanning Electron Microscopy (SEM) analysis was performed for fracture surface analyses. The tensile strength of all additively manufactured silicone soft tissue materials was significantly lower (p < 0.0001) than that of the control material. All additively manufactured soft tissue material groups had significantly higher compressive strengths (p < 0.0001) and Shore A hardness values. Accuracy analysis showed no significant difference between the groups when compared at the same printing angle (0°, 45°, and 90°); however, within each material group, printing at 45° had higher RMS values than specimens printed at an angle of 0° and 90°. The conventional soft tissue material (control) had a significantly higher tensile strength than all the AMed soft tissue materials, whereas the opposite trend was found for flexural strength and shore hardness. When selecting an AMed material for soft tissue casts used during implant restoration fabrication, it is recommended to print the soft tissues at either 0° or 90°.
- Open Access
- 1 March 2024
- Published by Elsevier in Journal of Dentistry
- Vol. 144, 104908
Factors influencing the bond strength of additively manufactured crown materials in dentistry: A systematic review of in vitro studies
- 1 March 2024
- Published by Elsevier in Journal of Dentistry
- Vol. 144, 104908
Open AccessFactors influencing the bond strength of additively manufactured crown materials in dentistry: A systematic review of in vitro studies