Susan P. James
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Susan P. James has a total of 15 co-authors. Here are the top co-authors by number of shared publications:
Min Zhang
Department of Mechanical Engineering, Biomedical Engineering Program, Colorado State University, Fort Collins, Colorado 80523-1374, USA
3 shared publicationsG P Beauregard
Rocky Mountain Materials Research, Department of Mechanical Engineering, Colorado State University, Fort Collins, Colorado 80523, USA
2 shared publicationsGuy P. Beauregard
Department of Mechanical Engineering, Colorado State University, Fort Collins, Colorado 80523‐1374
2 shared publicationsDavid W. Grainger
Department of Chemistry, Colorado State University, Fort Collins, Colorado 80523‐1872
1 shared publicationE D Rentfrow
Rocky Mountain Materials Research, Department of Mechanical Engineering, Colorado State University, Fort Collins 80523, USA
1 shared publicationE Rentfrow
1 shared publication
Latest Publications
- 6 April 2006
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 78A (1) , 86-96
A novel ultra high molecular weight polyethylene–hyaluronan microcomposite for use in total joint replacements. I. Synthesis and physical/chemical characterization
A novel microcomposite between ultra high molecular weight polyethylene (UHMWPE) and hyaluronan (HA) was developed to create a hydrophilic and lubricious UHMWPE surface for total joint replacement and other biomedical load‐bearing applications. Preforms with interconnected micropores were used as the UHMWPE starting material to form a microcomposite with HA, rather than starting with fully dense, bulk UHMWPE. HA was silylated first to increase its hydrophobicity and compatibility with UHMWPE. The silylated groups were removed through hydrolysis prior to final compression molding. A uniform and enzymatic degradation resistant HA film layer was produced on the microcomposite surface, which quickly hydrated in water, forming a lubricious surface film that was fully wetted by water drops during contact angle measurements. Presence of HA film on the composite surface was also demonstrated through X‐ray photoelectron spectroscopy analysis and Toluidine Blue O dye assay. The mechanical and tribological properties evaluation of the novel microcomposites are presented in Part II. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res, 2006
- 6 April 2006
- Published by Wiley in Journal of Biomedical Materials Research Part A
- Vol. 78A (1) , 86-96
A novel ultra high molecular weight polyethylene–hyaluronan microcomposite for use in total joint replacements. I. Synthesis and physical/chemical characterization
A novel microcomposite between ultra high molecular weight polyethylene (UHMWPE) and hyaluronan (HA) was developed to create a hydrophilic and lubricious UHMWPE surface for total joint replacement and other biomedical load‐bearing applications. Preforms with interconnected micropores were used as the UHMWPE starting material to form a microcomposite with HA, rather than starting with fully dense, bulk UHMWPE. HA was silylated first to increase its hydrophobicity and compatibility with UHMWPE. The silylated groups were removed through hydrolysis prior to final compression molding. A uniform and enzymatic degradation resistant HA film layer was produced on the microcomposite surface, which quickly hydrated in water, forming a lubricious surface film that was fully wetted by water drops during contact angle measurements. Presence of HA film on the composite surface was also demonstrated through X‐ray photoelectron spectroscopy analysis and Toluidine Blue O dye assay. The mechanical and tribological properties evaluation of the novel microcomposites are presented in Part II. © 2006 Wiley Periodicals, Inc. J Biomed Mater Res, 2006
- 1 June 2005
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 16 (6) , 587-593
Synthesis and properties of melt-processable hyaluronan esters
- 1 June 2005
- Published by Springer Nature in Journal of Materials Science: Materials in Medicine
- Vol. 16 (6) , 587-593
Synthesis and properties of melt-processable hyaluronan esters
- 1 June 2005
- Published by Springer Nature in Journal of Materials Science
- Vol. 40 (11) , 2937-2943
Synthesis and properties of melt-processable hyaluronan esters
- 1 June 2005
- Published by Springer Nature in Journal of Materials Science
- Vol. 40 (11) , 2937-2943
Synthesis and properties of melt-processable hyaluronan esters
- 21 March 2001
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 79 (12) , 2264-2271
Silylation of poly-L-lysine hydrobromide to improve dissolution in apolar organic solvents
- 21 March 2001
- Published by Wiley in Journal of Applied Polymer Science
- Vol. 79 (12) , 2264-2271
Silylation of poly-L-lysine hydrobromide to improve dissolution in apolar organic solvents
- 1 January 2001
- Vol. 37, 7-12
The effect of IPN surface modification on the mechanical properties of UHMWPE.
This paper investigates the effect of IPN surface treatment on the mechanical properties of ultra high molecular weight polyethylene (UHMWPE). Traditional UHMWPE was modified by introducing poly-L-lysine (PLL) into their surface and forming a semi-interpenetrating network (IPN). Tensile, creep and fatigue tests were performed on these IPN and the control specimens. The tensile and creep results show that the IPN modification did plasticize the UHMWPE in that it decreased modulus and strength, increased ductility, and degraded creep resistance. However, these property changes are not so large as to be unacceptable. In the fatigue tests, there were no failures of control nor IPN samples up to 10 million cycles.
- 1 January 2001
- Vol. 37, 7-12
The effect of IPN surface modification on the mechanical properties of UHMWPE.
This paper investigates the effect of IPN surface treatment on the mechanical properties of ultra high molecular weight polyethylene (UHMWPE). Traditional UHMWPE was modified by introducing poly-L-lysine (PLL) into their surface and forming a semi-interpenetrating network (IPN). Tensile, creep and fatigue tests were performed on these IPN and the control specimens. The tensile and creep results show that the IPN modification did plasticize the UHMWPE in that it decreased modulus and strength, increased ductility, and degraded creep resistance. However, these property changes are not so large as to be unacceptable. In the fatigue tests, there were no failures of control nor IPN samples up to 10 million cycles.
- 1 January 1999
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 48 (3) , 374-384
Clinical wear of 63 ultrahigh molecular weight polyethylene acetabular components: Effect of starting resin and forming method
This study compares the clinical wear rates and implant characteristics of 63 surgically retrieved acetabular components. All components were made by the same manufacturer, implanted by the same surgeon, in articulation against the same type of femoral component, and revised for the same reason; 19 were made from directly compression molded, calcium stearate free, ultrahigh molecular weight polyethylene (UHMWPE) and 44 were made from machined, ram extruded, calcium stearate containing UHMWPE. There were significant differences in wear, duration, and wear rate between the molded (type I) and machined (type II and III) components. Most importantly, the wear rates of type I (molded) components were significantly (p < 0.0001) lower than the wear rates of type II, type III, and type II and III components as a group (all machined). The machined components had wear rates 2.3 times greater than the molded components. The wear rates between the two different groups of machined components (type II and III) were not significantly different. The scanning electron microscope observations did not reveal any major differences in wear mechanisms between the three types of components, although the machined components did show more evidence of brittleness. The molded components were better consolidated (or had less fusion defects) than the ram extruded components. © 1999 John Wiley & Sons, Inc. J Biomed Mater Res (Appl Biomater) 48: 374–384, 1999
- 1 January 1999
- Published by Wiley in Journal of Biomedical Materials Research
- Vol. 48 (3) , 374-384
Clinical wear of 63 ultrahigh molecular weight polyethylene acetabular components: Effect of starting resin and forming method
This study compares the clinical wear rates and implant characteristics of 63 surgically retrieved acetabular components. All components were made by the same manufacturer, implanted by the same surgeon, in articulation against the same type of femoral component, and revised for the same reason; 19 were made from directly compression molded, calcium stearate free, ultrahigh molecular weight polyethylene (UHMWPE) and 44 were made from machined, ram extruded, calcium stearate containing UHMWPE. There were significant differences in wear, duration, and wear rate between the molded (type I) and machined (type II and III) components. Most importantly, the wear rates of type I (molded) components were significantly (p < 0.0001) lower than the wear rates of type II, type III, and type II and III components as a group (all machined). The machined components had wear rates 2.3 times greater than the molded components. The wear rates between the two different groups of machined components (type II and III) were not significantly different. The scanning electron microscope observations did not reveal any major differences in wear mechanisms between the three types of components, although the machined components did show more evidence of brittleness. The molded components were better consolidated (or had less fusion defects) than the ram extruded components. © 1999 John Wiley & Sons, Inc. J Biomed Mater Res (Appl Biomater) 48: 374–384, 1999
- 1 January 1999
- Vol. 35, 415-9
Synthesis and characterization of a novel UHMWPE interpenetrating polymer network.
A novel, biomimetic, interpenetrating polymer network (IPN) between poly-L-lysine (PLL) and ultra high molecular weight polyethylene (UHMWPE) has been synthesized in an attempt to decrease wear in joint prostheses. A biomaterial with a gradient IPN of cationic PLL and UHMWPE has been synthesized, in the surface of bulk UHMWPE, to recruit the poly-anion, hyaluronic acid, from the synovial fluid. It is hypothesized that the hyaluronic acid molecules and their associated hydration layer will improve lubrication between the articulating surfaces, thus lowering both friction and wear. The synthesis involves four steps. Silylation of the PLL-HBr to PLL-SiMe3 utilizing bis(trimethylsiyl)acetamide (BSA). Swelling of the UHMWPE in a solution of PLL-SiMe3/xylenes at 60 degrees C with ultrasonics. Crosslinking of the PLL-SiMe3 within the UHMWPE with 1,8-diisocyanatooctane (a.k.a. OMDI). Finally, de-swelling and drying of the IPN under vacuum at 50 C. Visual observations show an adhered film on the IPN surface. Reflective FTIR spectra contain the characteristic peaks associated with UHMWPE. Two additional peaks, at 3410 and 1690 cm-1, are associated with PLL. SEM shows a morphology dominated by PLL spheres with diameters ranging from < 1 micron up to 3 micron. This shows that the PLL-SiMe3 has been crosslinked by the OMDI and was not rinsed away by either xylenes or sonicated water rinses. High contact angle of the PLL in contact with the UHMWPE demonstrate that the PLL has been de-silylated and returned to its hydrophilic nature. The spheres attached to the surface of the UHMWPE indicate that PLL has infiltrated the UHMWPE physical network and is entangled there. XPS confirms the presence of nitrogen by a 3-5 atomic percent signal in the outer 100 A of the IPN surface.
- 1 January 1999
- Vol. 35, 415-9
Synthesis and characterization of a novel UHMWPE interpenetrating polymer network.
A novel, biomimetic, interpenetrating polymer network (IPN) between poly-L-lysine (PLL) and ultra high molecular weight polyethylene (UHMWPE) has been synthesized in an attempt to decrease wear in joint prostheses. A biomaterial with a gradient IPN of cationic PLL and UHMWPE has been synthesized, in the surface of bulk UHMWPE, to recruit the poly-anion, hyaluronic acid, from the synovial fluid. It is hypothesized that the hyaluronic acid molecules and their associated hydration layer will improve lubrication between the articulating surfaces, thus lowering both friction and wear. The synthesis involves four steps. Silylation of the PLL-HBr to PLL-SiMe3 utilizing bis(trimethylsiyl)acetamide (BSA). Swelling of the UHMWPE in a solution of PLL-SiMe3/xylenes at 60 degrees C with ultrasonics. Crosslinking of the PLL-SiMe3 within the UHMWPE with 1,8-diisocyanatooctane (a.k.a. OMDI). Finally, de-swelling and drying of the IPN under vacuum at 50 C. Visual observations show an adhered film on the IPN surface. Reflective FTIR spectra contain the characteristic peaks associated with UHMWPE. Two additional peaks, at 3410 and 1690 cm-1, are associated with PLL. SEM shows a morphology dominated by PLL spheres with diameters ranging from < 1 micron up to 3 micron. This shows that the PLL-SiMe3 has been crosslinked by the OMDI and was not rinsed away by either xylenes or sonicated water rinses. High contact angle of the PLL in contact with the UHMWPE demonstrate that the PLL has been de-silylated and returned to its hydrophilic nature. The spheres attached to the surface of the UHMWPE indicate that PLL has infiltrated the UHMWPE physical network and is entangled there. XPS confirms the presence of nitrogen by a 3-5 atomic percent signal in the outer 100 A of the IPN surface.
- 1 January 1996
- Vol. 32, 135-41
Comparison of the in vivo wear rates of 43 surgically retrieved direct compression molded and ram extruded ultra high molecular weight polyethylene acetabular components.
The objective of this study was to investigate retrieved ultra high molecular weight polyethylene (UHMWPE) liners from Total HIp Arthroplasty (THA) revisions. The amount of in vivo wear on compression molded v. ram extruded and machined acetabular liners was the focus of comparison between 43 surgically retrieved samples. The principal experimental methods were scanning electron microscope (SEM) observations and a fluid displacement method to quantify volumetric wear. SEM observations revealed similar wear mechanisms between the compression molded and ram extruded and machined UHMWPE retrieved liners. More third body wear corresponded with more volumetric in vivo wear. This study found that the ram extruded and machined UHMWPE liners had a significantly larger average wear rate than the compression molded UHMWPE liners. In order to determine whether the observed difference in wear rates can be attributed to the different types of UHMWPE processing, a more controlled experiment would have to be performed.
- 1 January 1996
- Vol. 32, 135-41
Comparison of the in vivo wear rates of 43 surgically retrieved direct compression molded and ram extruded ultra high molecular weight polyethylene acetabular components.
The objective of this study was to investigate retrieved ultra high molecular weight polyethylene (UHMWPE) liners from Total HIp Arthroplasty (THA) revisions. The amount of in vivo wear on compression molded v. ram extruded and machined acetabular liners was the focus of comparison between 43 surgically retrieved samples. The principal experimental methods were scanning electron microscope (SEM) observations and a fluid displacement method to quantify volumetric wear. SEM observations revealed similar wear mechanisms between the compression molded and ram extruded and machined UHMWPE retrieved liners. More third body wear corresponded with more volumetric in vivo wear. This study found that the ram extruded and machined UHMWPE liners had a significantly larger average wear rate than the compression molded UHMWPE liners. In order to determine whether the observed difference in wear rates can be attributed to the different types of UHMWPE processing, a more controlled experiment would have to be performed.