Renshi Sawada
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Renshi Sawada has a total of 25 co-authors. Here are the top co-authors by number of shared publications:
- Eiji Higurashi
Graduate School of Engineering, Tohoku University, Sendai, Japan
5 shared publications - Hirofumi Nogami
Department of Mechanical Engineering, Faculty of Engineering, Kyushu University, 744 Motooka, Nishi-ku, Fukuoka 819-0395, Japan
2 shared publications A. Shimizu
NTT Microsystem Integration Labs., Kanagawa, Japan
1 shared publication- Bin Sun
Institute of Biomedical and Health Engineering, Shenzhen Institute of Advanced Technology, Chinese Academy of Science, Shenzhen 518055, China
1 shared publication - Guifu Ding
National Key Laboratory of Advanced Micro and Nano Manufacture Technology, Shanghai Jiao Tong University, Shanghai, China
1 shared publication J. Yamaguchi
NTT Microsystem Integration Labs., Kanagawa, Japan
1 shared publication
Latest Publications
- Open Access
- 1 February 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (2) , 61
Fabrication of Electromagnetically-Driven Tilted Microcoil on Polyimide Capillary Surface for Potential Single-Fiber Endoscope Scanner Application
The design and fabrication of a Micro-electromechanical Systems (MEMS)-based tilted microcoil on a polyimide capillary are reported in this paper, proposed for an electromagnetically-driven single-fiber endoscope scanner application. The parameters of the tilted microcoil were optimized by simulation. It is proved that the largest driving force could be achieved when the tilt-angle, the pitch and the coil turns of the designed microcoil were 60°, 80 µm and 20, respectively. The modal simulation of the designed fiber scanner was carried out. The prototypes of the tilted microcoils were fabricated on the surface of polyimide capillary with 1 mm-diameter using our developed cylindrical projection lithography system. The dimensions of the two tilted microcoils were as follows: one was tilt-angle 45°, line width 10 ± 0.2 µm, coil pitch 78.5 ± 0.5 µm, and the other was tilt-angle 60°, line width 10 ± 0.2 µm, coil pitch 81.5 ± 0.5 µm. Finally, a direct mask-less electroplating process was employed to fabricate the copper microcoil with 15 µm thickness on the gold (Au) seed-layer, and the corresponding line width was expanded to 40 µm.
- 1 February 2018
- Published by MDPI AG in Micromachines
- Vol. 9 (2) , 61
Open AccessFabrication of Electromagnetically-Driven Tilted Microcoil on Polyimide Capillary Surface for Potential Single-Fiber Endoscope Scanner Application
The design and fabrication of a Micro-electromechanical Systems (MEMS)-based tilted microcoil on a polyimide capillary are reported in this paper, proposed for an electromagnetically-driven single-fiber endoscope scanner application. The parameters of the tilted microcoil were optimized by simulation. It is proved that the largest driving force could be achieved when the tilt-angle, the pitch and the coil turns of the designed microcoil were 60°, 80 µm and 20, respectively. The modal simulation of the designed fiber scanner was carried out. The prototypes of the tilted microcoils were fabricated on the surface of polyimide capillary with 1 mm-diameter using our developed cylindrical projection lithography system. The dimensions of the two tilted microcoils were as follows: one was tilt-angle 45°, line width 10 ± 0.2 µm, coil pitch 78.5 ± 0.5 µm, and the other was tilt-angle 60°, line width 10 ± 0.2 µm, coil pitch 81.5 ± 0.5 µm. Finally, a direct mask-less electroplating process was employed to fabricate the copper microcoil with 15 µm thickness on the gold (Au) seed-layer, and the corresponding line width was expanded to 40 µm.
- Open Access
Grasping Force Control for a Robotic Hand by Slip Detection Using Developed Micro Laser Doppler Velocimeter
The purpose of this paper is to show the feasibility of grasping force control by feeding back signals of the developed micro-laser Doppler velocimeter (μ-LDV) and by discriminating whether a grasped object is slipping or not. LDV is well known as a high response surface velocity sensor which can measure various surfaces—such as metal, paper, film, and so on—thus suggesting the potential application of LDV as a slip sensor for grasping various objects. However, the use of LDV as a slip sensor has not yet been reported because the size of LDVs is too large to be installed on a robotic fingertip. We have solved the size problem and enabled the performance of a feasibility test with a few-millimeter-scale LDV referred to as micro-LDV (μ-LDV) by modifying the design which was adopted from MEMS (microelectromechanical systems) fabrication process. In this paper, by applying our developed μ-LDV as a slip sensor, we have successfully demonstrated grasping force control with three target objects—aluminum block, wood block, and white acrylic block—considering that various objects made of these materials can be found in homes and factories, without grasping force feedback. We provide proofs that LDV is a new promising candidate slip sensor for grasping force control to execute target grasping.
Open AccessGrasping Force Control for a Robotic Hand by Slip Detection Using Developed Micro Laser Doppler Velocimeter
The purpose of this paper is to show the feasibility of grasping force control by feeding back signals of the developed micro-laser Doppler velocimeter (μ-LDV) and by discriminating whether a grasped object is slipping or not. LDV is well known as a high response surface velocity sensor which can measure various surfaces—such as metal, paper, film, and so on—thus suggesting the potential application of LDV as a slip sensor for grasping various objects. However, the use of LDV as a slip sensor has not yet been reported because the size of LDVs is too large to be installed on a robotic fingertip. We have solved the size problem and enabled the performance of a feasibility test with a few-millimeter-scale LDV referred to as micro-LDV (μ-LDV) by modifying the design which was adopted from MEMS (microelectromechanical systems) fabrication process. In this paper, by applying our developed μ-LDV as a slip sensor, we have successfully demonstrated grasping force control with three target objects—aluminum block, wood block, and white acrylic block—considering that various objects made of these materials can be found in homes and factories, without grasping force feedback. We provide proofs that LDV is a new promising candidate slip sensor for grasping force control to execute target grasping.
- Open Access
Detection of Site-Specific Blood Flow Variation in Humans during Running by a Wearable Laser Doppler Flowmeter
Wearable wireless physiological sensors are helpful for monitoring and maintaining human health. Blood flow contains abundant physiological information but it is hard to measure blood flow during exercise using conventional blood flowmeters because of their size, weight, and use of optic fibers. To resolve these disadvantages, we previously developed a micro integrated laser Doppler blood flowmeter using microelectromechanical systems technology. This micro blood flowmeter is wearable and capable of stable measurement signals even during movement. Therefore, we attempted to measure skin blood flow at the forehead, fingertip, and earlobe of seven young men while running as a pilot experiment to extend the utility of the micro blood flowmeter. We measured blood flow in each subject at velocities of 6, 8, and 10 km/h. We succeeded in obtaining stable measurements of blood flow, with few motion artifacts, using the micro blood flowmeter, and the pulse wave signal and motion artifacts were clearly separated by conducting frequency analysis. Furthermore, the results showed that the extent of the changes in blood flow depended on the intensity of exercise as well as previous work with an ergometer. Thus, we demonstrated the capability of this wearable blood flow sensor for measurement during exercise.
Open AccessDetection of Site-Specific Blood Flow Variation in Humans during Running by a Wearable Laser Doppler Flowmeter
Wearable wireless physiological sensors are helpful for monitoring and maintaining human health. Blood flow contains abundant physiological information but it is hard to measure blood flow during exercise using conventional blood flowmeters because of their size, weight, and use of optic fibers. To resolve these disadvantages, we previously developed a micro integrated laser Doppler blood flowmeter using microelectromechanical systems technology. This micro blood flowmeter is wearable and capable of stable measurement signals even during movement. Therefore, we attempted to measure skin blood flow at the forehead, fingertip, and earlobe of seven young men while running as a pilot experiment to extend the utility of the micro blood flowmeter. We measured blood flow in each subject at velocities of 6, 8, and 10 km/h. We succeeded in obtaining stable measurements of blood flow, with few motion artifacts, using the micro blood flowmeter, and the pulse wave signal and motion artifacts were clearly separated by conducting frequency analysis. Furthermore, the results showed that the extent of the changes in blood flow depended on the intensity of exercise as well as previous work with an ergometer. Thus, we demonstrated the capability of this wearable blood flow sensor for measurement during exercise.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1955-1958
Development and Use of a Micro Optical Blood Flow Sensor Based on Systemin Package (SIP) Technology that Fuses Optical MEMS and Integrated Circuit to Detect Avian Influenza
Based on system-in-package (SiP) technologies that fuse a micromachined optical Doppler blood-flow sensor chip and integrated electronic circuit (IC) chips, very small wireless blood-flow sensors to be attached to birds have been fabricated. Because micromachined blood-flow sensors (MEMS sensors) are very compact and stable, and in addition the SiP design does not jeopardize the form factor and characteristics of the MEMS sensors, they are effective for wireless monitoring of blood flow when attached to the breast of the chicken. Blood flow is an important factor, in addition to body temperature and behavior, for monitoring seriously infected chickens.
- 1 January 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 1955-1958
Development and Use of a Micro Optical Blood Flow Sensor Based on Systemin Package (SIP) Technology that Fuses Optical MEMS and Integrated Circuit to Detect Avian Influenza
Based on system-in-package (SiP) technologies that fuse a micromachined optical Doppler blood-flow sensor chip and integrated electronic circuit (IC) chips, very small wireless blood-flow sensors to be attached to birds have been fabricated. Because micromachined blood-flow sensors (MEMS sensors) are very compact and stable, and in addition the SiP design does not jeopardize the form factor and characteristics of the MEMS sensors, they are effective for wireless monitoring of blood flow when attached to the breast of the chicken. Blood flow is an important factor, in addition to body temperature and behavior, for monitoring seriously infected chickens.
- 26 June 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Free-space optical cross connect switch based on a 3D MEMS mirror array
The design and characteristics of a 3D MEMS mirror array and a compact optical fiber array as well as the free-space optical cross connect (OXC) switch module comprising them are presented.
- 26 June 2003
- Published by Institute of Electrical and Electronics Engineers (IEEE)
Free-space optical cross connect switch based on a 3D MEMS mirror array
The design and characteristics of a 3D MEMS mirror array and a compact optical fiber array as well as the free-space optical cross connect (OXC) switch module comprising them are presented.
- 8 June 1998
- Published by AIP Publishing in Applied Physics Letters
- Vol. 72 (23) , 2951-2953
Optically induced rotation of a trapped micro-object about an axis perpendicular to the laser beam axis
A strongly focused Nd:YAG laser beam has been used experimentally to achieve optical trapping and simultaneous rotation of a micro-object about an axis perpendicular to the trapping laser beam axis. The micro-object (12 μm in diameter), which has shape anisotropy in its interior, can be produced by oxygen reactive ion etching of a fluorinated polyimide film (refractive index n=1.53). This optically induced rotation of the micro-object in ethanol (n=1.36) is accomplished by utilizing the net radiation pressure force arising from the momentum change of light scattered at the micro-object’s inner walls.
- 8 June 1998
- Published by AIP Publishing in Applied Physics Letters
- Vol. 72 (23) , 2951-2953
Optically induced rotation of a trapped micro-object about an axis perpendicular to the laser beam axis
A strongly focused Nd:YAG laser beam has been used experimentally to achieve optical trapping and simultaneous rotation of a micro-object about an axis perpendicular to the trapping laser beam axis. The micro-object (12 μm in diameter), which has shape anisotropy in its interior, can be produced by oxygen reactive ion etching of a fluorinated polyimide film (refractive index n=1.53). This optically induced rotation of the micro-object in ethanol (n=1.36) is accomplished by utilizing the net radiation pressure force arising from the momentum change of light scattered at the micro-object’s inner walls.