    In Vitro Testing of Lumbar Disc Arthroplasty Devices

    by Denis J. Mohi DiAngelo, Kevin T. Foley, Brian P. Morrow, Peter Wong, Kelly Kiehm, Anthony Sin, Rudolf Bertagnoli, Celeste Abjornson, Brian P. Kelly


  • Biomechanical Comparison of a Novel C1 Posterior Locking Plate With the Harms Technique in A C1–C2 Fixation Model

    by Brian P. Kelly, John A. Glaser, Denis J. DiAngelo

    A biomechanical testing protocol was used to study atlantoaxial fixation techniques in a human cadaveric model. To compare the in vitro biomechanics of locking plate fixation of the posterior arch of C1 to C2 laminar screw fixation, with that of conventional C1 lateral mass to C2 pars screw fixation. Current methods of atlantoaxial fixation pose a risk to neurologic and vascular structures. A novel posterior locking plate for C1 was designed, that when rigidly linked to C2 translaminar screws may offer alternative C1-C2 fixation with greatly decreased surgical risk. No comparative in vitro biomechanical testing has been previously done to evaluate the feasibility of this method. Cadaveric and CT assessments of the thickness of the C1 ring were performed. Seven spines (C0-C4) were evaluated in flexion-extension, left-right bending, and left-right axial rotation in a cadaveric C1-C2 fixation model. Three conditions were evaluated: (1) intact spine, and after odontoidectomy, (2) C1 plate to C2 laminar screw fixation, (3) C1 lateral mass to C2 pars screw fixation. Flexibility and motion data were compared using a 1-way RM analysis of variance and Student-Newman-Kuels tests. Anatomic data indicated that 6 mm of screw purchase was viable for C1 plate fixation. Both the Harms and C1-plated conditions significantly reduced global flexibility in flexion-extension and left-right axial rotation. Motion at the C1-C2 level was significantly reduced for all loading modes for both instrumented conditions with the exception of the C1 plate in right bending. No significant differences occurred between the 2 fixation methods. A novel C1 posterior locking plate was designed and tested in a C1-C2 fixation model. The C1 locking plate technique functioned in an equivalent manner to the existing Harms technique. The C1 plate may be a viable alternative that is technically less demanding with decreased surgical risk.


  • Biomechanical Testing of a Novel Four-Rod Technique For Lumbo-Pelvic Reconstruction

    by Brian P. Kelly, Francis H. Shen, John S. Schwab, Vincent Arlet, Denis J. DiAngelo

    A biomechanical testing protocol was used to study different lumbo-pelvic fixation techniques in a human cadaveric lumbar spine model. To compare the in vitro biomechanics of a novel four-rod lumbo-pelvic reconstruction technique with and with out cross-links, to that of a conventional cross-linked two-rod technique. Numerous lumbo-pelvic reconstruction methods based on the Galveston two-rod technique have been proposed for cases involving total sacrectomy. Recently a technique that proposes novel use of 4 supporting longitudinal rods across the lumbo-pelvic junction has been reported. No comparative in vitro biomechanical testing has been previously done to evaluate these different reconstruction methods. Five spines were evaluated in flexion, extension, left-right lateral bending and left-right axial rotation in a human total sacrectomy model. The model was comprised of cadaveric lumbar spines (L1-L5) with custom fabricated polyethylene blocks used to simulate pelvic fixation. Three conditions were evaluated: Linked Four-Rod, Linked Two-Rod, and Four-Rod (no cross-links). Flexibility and motion data were compared using a one-way repeated measures analysis of variance and SNK tests. The Linked Four-Rod and Four-Rod conditions significantly decreased flexibility and reduced L5-Pelvic motion over the Linked Two-Rod construct in flexion and extension. The Linked Four-Rod condition significantly decreased flexibility in left-right axial rotation compared with the Four-Rod and Linked Two-Rod conditions. No significant differences occurred in relative lateral movement between left and right pelvic polyethylene blocks. The four-rod technique improved fixation stability over the conventional linked two-rod technique in flexion and extension, and when cross-linked, in left-right axial rotation. The four-rod technique also significantly reduced L5-Pelvic junction movement in flexionand extension, which may have implications for bony fusion. The use of cross-links is recommended.