DDDenis J. DiAngelo

Denis J. DiAngelo

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Denis J. DiAngelo has a total of 23 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    In Vitro Testing of Lumbar Disc Arthroplasty Devices

    by Denis J. Mohi DiAngelo, Kevin T. Foley, Brian P. Morrow, Peter Wong, Kelly Kiehm, Anthony Sin, Rudolf Bertagnoli, Celeste Abjornson, Brian P. Kelly


  • In vitro biomechanics of cervical disc arthroplasty with the ProDisc-C total disc implant

    by Denis J. DiAngelo, Kevin T. Foley, Brian R. Morrow, John S. Schwab, Jung Song, John W. German, Eve Blair

    An in vitro biomechanical study was conducted to compare the effects of disc arthroplasty and anterior cervical fusion on cervical spine biomechanics in a multilevel human cadaveric model. Three spine conditions were studied: harvested, single-level cervical disc arthroplasty, and single-level fusion. A programmable testing apparatus was used that replicated physiological flexion/extension, lateral bending, and axial rotation. Measurements included vertebral motion, applied load, and bending moments. Relative rotations at the superior, treated, and inferior motion segment units (MSUs) were normalized with respect to the overall rotation of those three MSUs and compared using a one-way analysis of variance with Student–Newman–Keuls test (p < 0.05). Simulated fusion decreased motion across the treated site relative to the harvested and disc arthroplasty conditions. The reduced motion at the treated site was compensated at the adjacent segments by an increase in motion. For all modes of testing, use of an artificial disc prosthesis did not alter the motion patterns at either the instrumented level or adjacent segments compared with the harvested condition, except in extension.


  • Biomechanical Testing of an Artificial Cervical Joint and an Anterior Cervical Plate

    by Denis J. DiAngelo, James T. Roberston, Newton H. Metcalf, Bobby J. McVay, R. Champ Davis

    An in vitro biomechanical study was conducted to determine the effects of fusion and nonfusion anterior cervical instrumentation on cervical spine biomechanics in a multilevel human cadaveric model. Three spine conditions were studied: harvested, single-level artificial cervical joint, and single-level graft with anterior cervical plate. A programmable testing apparatus was used that replicated physiologic flexion/extension and lateral bending. Measurements included vertebral motion, applied load, and bending moments. Relative rotations at the superior, implanted, and inferior motion segment units (MSUs) were normalized with respect to the overall rotation of those three MSUs and compared using a one-way analysis of variance (P < 0.05). Application of an anterior cervical plate decreased motion across the fusion site relative to the harvested and artificial joint spine conditions. The reduced motion was compensated for by an increase in motion at the adjacent segments. Use of an artificial cervical joint did not alter the motion patterns at either the instrumented level or the adjacent segments compared with the harvested condition for all modes of testing.


  • Bioabsorbable Anterior Lumbar Plate Fixation in Conjunction with Anterior Interbody Fusion Cages

    by Denis J DiAngelo, Scott Kitchel, Bobby J McVay, Jeffrey L Scifert, G Bryan Cornwall

    An in vitro biomechanical study was conducted to determine the effects of anterior stabilization on lumbar interbody cage fusion biomechanics in a multilevel human cadaveric lumbar model. Three spine conditions were compared: harvested, bilateral multilevel cages (CAGES), and CAGES with bioabsorbable anterior plates (CBAP), tested under flexion/extension, lateral bending, and axial rotation. Measurements included vertebral motion, applied load, and bending/rotational moments. Application of anterior fixation decreased local motion and increased stiffness of the instrumented levels. Clinically, this spinal stability may serve to promote fusion. Coupled with the bioabsorbability of the plating material, the bioabsorbable anterior lumbar plating system is considered biomechanically advantageous.


  • An Improved Testing Protocol for Evaluating Anterior Spinal Instrumentation Using Graft Loads in a Single-Level Cervical Discectomy or Corpectomy Model

    by Denis J. DiAngelo, Geza Osztheimer, Kevin T. Foley

    Anterior cervical instrumentation used in discectomy or corpectomy graft fusion should restore the mechanical integrity of the operated spine and decrease graft complications. For fusion to occur, the spinal instrumentation must load-share with the interbody graft. Recent design changes in anterior cervical plates (ACP) aim to allow motion across the fusion site and load share with the graft [1]. However, existing American Society for Testing and Materials (ASTM) standards (F1717-96) for static and fatigue testing of spinal implant constructs in a corpectomy model do not include an interbody graft in the test method [2]. The objective of this study was to develop a non-destructive testing protocol and apparatus to rank the static and low-endurance performance of ACP instrumentation in single-level discectomy and corpectomy graft-plate models.


  • Biomechanical Comparison of Single-Level Cervical Plate Fusion and Interbody Cage Fusion

    by Denis J. DiAngelo, Amanda L. Thomas, Kevin T. Foley

    Anterior cervical graft fusion alone or supplemented with an anterior cervical plate instrumentation may be used to treat the diseased cervical spine. An anterior cervical plate is intended to restore the mechanical integrity of the operated spine and decrease graft complications. An alternative method to single-level graft fusion is to use an interbody fusion device. The objective of this study was to compare the biomechanical stability of a single-level graft-plated cervical construct with an interbody cage device.