PLPhilip Langley

Philip Langley

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Philip Langley has a total of 21 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Spatial Pattern of P Waves in Paroxysmal Atrial Fibrillation Patients in Sinus Rhythm and Controls

    by Daniele Giacopelli, John P. Bourke, Alan Murray, Philip Langley

    Background: Measuring body surface potentials in the assessment of the electrical activity of the heart is the most commonly used noninvasive method for diagnosing cardiac arrhythmias. Paroxysmal atrial fibrillation (PAF) patients have disturbed cardiac electrophysiology but the detailed characteristics of atrial activation on the body surface are unknown. Methods: P waves from 60 sites on the body surface were analyzed from 10 PAF patients in sinus rhythm (PAF group) and 10 healthy controls (HC group). Evolution of atrial depolarization was described qualitatively by maps of P‐wave amplitudes. P‐wave dipole evolution was described quantitatively by measuring the changing location (body site) and amplitude of the dipole positive and negative pole peaks. Results: Both groups exhibited similar dipolar structure with an area of positive and an area of negative potentials. Over the depolarization cycle, there were significant changes in the location of the dipole with the positive pole rotating anteriorly right to left by two electrode sites (10 cm) (P = 0.001). There were significant differences between groups with the positive pole in PAF offset to the right of the chest by 0.43 (0.38) strips compared to HC (P < 0.007). Compared to controls, the PAF group positive poles reached peak amplitude sooner (49 [11] ms vs 65 [14] ms, P = 0.012) and negative poles reached peak amplitude later (74 [13] ms vs 62 [8] ms, P = 0.019). Conclusion: Atrial depolarization is characterized by a single dipole with time‐varying amplitude and orientation with significant differences in dipole trajectory between patients with PAF and HCs. (PACE 2012;00:1–8)


  • Accuracy of algorithms for detection of atrial fibrillation from short duration beat interval recordings

    by P. Langley, M. Dewhurst, L.Y. Di Marco, P. Adams, F. Dewhurst, J.C. Mwita, R. Walker, A. Murray

    Atrial fibrillation (AF) is characterised by highly variable beat intervals. The aims of the study were to assess the accuracy of AF detection algorithms from short analysis durations and to validate prospectively the accuracy on a large community-based cohort of elderly subjects. Three algorithms for AF detection were evaluated: coefficient of variation (CV), mean successive difference (Δ) and coefficient of sample entropy (COSEn), using two databases of beat interval recordings: 167 recordings of 300 s duration for a range of rhythms acquired in a hospital setting and 2130 recordings of 10s duration acquired in the community. Using the longer recordings receiver operating characteristic (ROC) analysis was used to identify optimal algorithm thresholds and to evaluate analysis durations ranging from 5s to 60s. An ROC area of 93% was obtained at recording duration of 60s but remained above 90% for durations as low as 5s. Prospective analysis on the 2130 recordings gave AF detector sensitivities from 90.5% (CV and Δ) to 95.2% (COSEn), specificities from 89.3% (Δ) to 93.4% (COSEn) and accuracy from 89.3% (Δ) to 93.4% (COSEn), not significantly different to those obtained on the initial database. AF detection algorithms are effective for short analysis durations, offering the prospect of a simple and rapid diagnostic test based on beat intervals alone.


  • Circadian variation of human ventricular fibrillation dominant frequency

    by Philip Langley, Guy A. MacGowan, Alan Murray


  • Principal Component Analysis as a Tool for Analyzing Beat-to-Beat Changes in ECG Features: Application to ECG-Derived Respiration

    by Philip Langley, Emma J. Bowers, Alan Murray

    An algorithm for analyzing changes in ECG morphology based on principal component analysis (PCA) is presented and applied to the derivation of surrogate respiratory signals from single-lead ECGs. The respiratory-induced variability of ECG features, P waves, QRS complexes, and T waves are described by the PCA. We assessed which ECG features and which principal components yielded the best surrogate for the respiratory signal. Twenty subjects performed controlled breathing for 180 s at 4, 6, 8, 10, 12, and 14 breaths per minute and normal breathing. ECG and breathing signals were recorded. Respiration was derived from the ECG by three algorithms: the PCA-based algorithm and two established algorithms, based on RR intervals and QRS amplitudes. ECG-derived respiration was compared to the recorded breathing signal by magnitude squared coherence and cross-correlation. The top ranking algorithm for both coherence and correlation was the PCA algorithm applied to QRS complexes. Coherence and correlation were significantly larger for this algorithm than the RR algorithm(p < 0.05 and p < 0.0001, respectively) but were not significantly different from the amplitude algorithm. PCA provides a novel algorithm for analysis of both respiratory and nonrespiratory related beat-to-beat changes in different ECG features.


  • Open Access

    Spatial and temporal organization of the dominant frequencies in the fibrillating heart: body surface potential mapping in a rare case of sustained human ventricular fibrillation

    by P. Langley, G.A. MacGowan, A. Murray

    The aim of this study was to assess the spatial and temporal variability of dominant fibrillation frequencies in a rare case of sustained human ventricular fibrillation (VF). Body surface potential mapping was performed in a patient with sustained VF and who was supported by a biventricular assist device. Dominant frequencies at 54 body sites were calculated from two recordings obtained 38 days apart. Variability of dominant frequencies between recordings and across body sites was quantified. Median dominant frequencies within recordings varied between 6.1 and 7.2 Hz in recording 1 and 5.6 and 6.6 Hz in recording 2, indicating a significant reduction in dominant frequencies between the recordings ( P < 0.0001). Dominant frequencies differed across body sites by a mean (range) of 1.7 (0.4–2.8) Hz. In this rare case of sustained VF, there was significant spatial and temporal variability of VF dominant frequencies. These findings should be considered in future ECG studies on VF where the spatial variability of dominant frequency might not otherwise have been considered.


    • 1 July 2007
      • p. 20-2

    Comparison of magnetocardiography and electrocardiography.

    by Fiona E Smith, Philip Langley, Peter Van Leeuwen, Birgit Hailer, Lutz Trahms, Uwe Steinhoff, John P Bourke, Alan Murray

    Automated techniques were developed for the measurement of cardiac repolarisation using magnetocardiography. This was achieved by collaboration with the Physikalisch-Technische Bundesanstalt (PTB), Berlin, Germany and the Grönemeyer Institute of Microtherapy, Bochum, Germany, to obtain recordings of magnetocardiograms (MCGs) in cardiac patients and healthy subjects. Manual and automated ventricular repolarisation measurements from MCGs were evaluated to determine the clinical relevance of these measurements compared with electrocardiograms (ECGs). Results showed that MCG and ECG T-wave shapes differed and that manual repolarisation measurement was significantly influenced by T-wave amplitude. Automatic measurements of repolarisation in both MCGs and ECGs differed between techniques. The effects of filtering on the waveforms showed that filtering in some MCG research systems could significantly influence the results, with 20 ms differences common. In addition, MCGs were better able to identify differences in the distribution of cardiac magnetic field strength during repolarisation and depolarisation between normal subjects and cardiac patients. Differences were also determined in ventricular repolarisation between MCGs and ECGs, which cannot be explained by channel/lead numbers or amplitude effects alone. The techniques developed are essential, because of the many extra MCG channels to analyse, and will encourage the use of MCG facilities.


  • Comparison of Automatic Repolarization Measurement Techniques in the Normal Magnetocardiogram

    by Fiona E. Smith, Philip Langley, Lutz Trahms, Uwe Steinhoff, John P. Bourke, Alan Murray

    Multichannel MCG noninvasively measures cardiac magnetic field strength from many sites at the body surface, potentially providing useful regional information about ventricular repolarization. Previous work on ECGs has shown that automatic techniques for repolarization measurement are better than manual measurement at discriminating patients with cardiac conditions from normal subjects. Although automatic repolarization measurement techniques have been quantified for ECGs, no comparative data exists for the MCG. In this study four different automatic repolarization (QT) interval techniques for detecting T wave end in the MCG were compared. The influence of MCG filtering on the automatic algorithms was also quantified. MCGs were obtained at 49 sites over the heart from 23 normal subjects. Automatic measurements of the repolarization (QT) interval were made following the addition of different high pass (0.25, 0.5, 1 Hz) and low pass (100, 60, 40, 30 Hz) filters. There were consistent differences between automatic techniques in the unfiltered data amounting to greatest mean difference of 52.3 ms. Low pass filtering significantly increased the automatic repolarization (QT) interval relative to unfiltered measurement by 6.5 (3.2) ms (mean SD) for 100 Hz, 6.0 (3.0) ms for 60 Hz, 8.1 (3.2) ms for 40 Hz, and 8.8 (3.1) ms for 30 Hz across all techniques. High pass filtering significantly decreased the value by −2.6 (6.0) ms for 0.25 Hz, −5.5 (5.3) ms for 0.5 Hz, and −17.1 (7.8) ms for 1 Hz. Automatic measurements of repolarization (QT) in the MCG differ between techniques and are influenced by filtering. These effects should be considered when comparing results. (PACE 2003; 26:2096–2102)


  • Quantification of T Wave Shape Changes Following Exercise

    by Philip Langley, Diego DI Bernardo, Alan Murray

    LANGLEY, P., et al.: Quantification of T Wave Shape Changes Following Exercise. T wave shape is increasingly used to provide insights into cardiac repolarization and, although shape is known to chan...