HQHarry M. Quiney

Harry M. Quiney

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Harry M. Quiney has a total of 163 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Signal-to-noise and spatial resolution in in-line imaging. 3. Optimization using a simple model

    by Timur E. Gureyev, David M. Paganin, Harry M. Quiney

    The problem of optimization of propagation-based phase-contrast imaging setups is considered in the case of projection X-ray imaging and three-dimensional tomography with phase retrieval. For two-dimensional imaging, a simple model for a homogeneous edge feature embedded in a bulk sample is used to obtain analytical expressions for the image intensity. This model allows for explicit optimization of the geometrical parameters of the imaging setup and the choice of X-ray energy that maximizes the image contrast or the contrast-to-noise ratio. We also consider the question of optimization of the biomedical X-ray imaging quality characteristic which balances the contrast-to-noise against the spatial resolution and the radiation dose. In the three-dimensional case corresponding to propagation-based phase-contrast tomography with phase retrieval according to Paganin's method, the optimization of the imaging setup is studied with respect to the source size, the detector resolution, the geometrical magnification and the X-ray energy. The optimization is performed explicitly only for monochromatic X-ray beams. However, it is shown that the optimizations with respect to magnification and the X-ray energy can be performed independently of each other, and, in particular, the optimal magnification remains the same for all X-ray energies within the validity range of the used approximations.


  • Open Access

    Signal-to-noise and spatial resolution in in-line imaging. 2. Phase-contrast tomography

    by Timur E. Gureyev, David M. Paganin, Konstantin M. Pavlov, Anton Maksimenko, Harry M. Quiney

    In the first part of this paper, quantitative aspects of propagation-based phase-contrast imaging (PBI) were investigated using theoretical and numerical approaches, as well as experimental two-dimensional PBI images collected with plane monochromatic X-rays at a synchrotron beamline. In this second part, signal-to-noise ratio, spatial resolution and contrast are studied in connection with the radiation dose in three-dimensional PBI images of breast tissue samples obtained using propagation-based phase-contrast computed tomography (PB-CT) with energy-integrating and photon-counting detectors. The analysis is based on the theory of PBI and PB-CT using the homogeneous Transport of Intensity equation (Paganin's method). A biomedical X-ray imaging quality characteristic, suitable for quantitative assessment of X-ray images of biological samples, is introduced and applied. The key factors leading to high values of the biomedical X-ray imaging quality in PBI and to relatively low values of the same quality metric in CT imaging are identified and discussed in detail. This study is aimed primarily at developing tools for quantitative assessment and optimization of medical PB-CT imaging, initially at synchrotron facilities, with the prospect of subsequent transfer of the technology to medical clinics.


  • Open Access

    Heavy-element damage seeding in proteins under XFEL illumination

    by Spencer K. Passmore, Alaric L. Sanders, Andrew V. Martin, Harry M. Quiney

    Serial femtosecond X-ray crystallography (SFX) captures the structure and dynamics of biological macromolecules at high spatial and temporal resolutions. The ultrashort pulse produced by an X-ray free-electron laser (XFEL) `outruns' much of the radiation damage that impairs conventional crystallography. However, the rapid onset of `electronic damage' due to ionization limits this benefit. Here, we distinguish the influence of different atomic species on the ionization of protein crystals by employing a plasma code that tracks the unbound electrons as a continuous energy distribution. The simulations show that trace quantities of heavy atoms ( Z > 10) contribute a substantial proportion of global radiation damage by rapidly seeding electron ionization cascades. In a typical protein crystal, sulfur atoms and solvated salts induce a substantial fraction of light-atom ionization. In further modeling of various targets, global ionization peaks at photon energies roughly 2 keV above inner-shell absorption edges, where sub-2 keV photoelectrons ejected from these shells initiate ionization cascades that are briefer than the XFEL pulse. These results indicate that relatively small quantities of heavy elements can substantially affect global radiation damage in XFEL experiments.


  • Open Access

    Signal-to-noise and spatial resolution in in-line imaging. 1. Basic theory, numerical simulations and planar experimental images

    by Timur E. Gureyev, David M. Paganin, Harry M. Quiney

    Signal-to-noise ratio and spatial resolution are quantitatively analysed in the context of in-line (propagation based) X-ray phase-contrast imaging. It is known that free-space propagation of a coherent X-ray beam from the imaged object to the detector plane, followed by phase retrieval in accordance with Paganin's method, can increase the signal-to-noise in the resultant images without deteriorating the spatial resolution. This results in violation of the noise-resolution uncertainty principle and demonstrates `unreasonable' effectiveness of the method. On the other hand, when the process of free-space propagation is performed in software, using the detected intensity distribution in the object plane, it cannot reproduce the same effectiveness, due to the amplification of photon shot noise. Here, it is shown that the performance of Paganin's method is determined by just two dimensionless parameters: the Fresnel number and the ratio of the real decrement to the imaginary part of the refractive index of the imaged object. The relevant theoretical analysis is performed first, followed by computer simulations and then by a brief test using experimental images collected at a synchrotron beamline. More extensive experimental tests will be presented in the second part of this paper.


  • Open Access

    Propagation-based phase-contrast imaging of the breast: image quality and the effect of X-ray energy and radiation dose

    by Indusaa Gunaseelan, Alaleh Amin Zadeh, Benedicta Arhatari, Anton Maksimenko, Christopher Hall, Daniel Hausermann, Beena Kumar, Jane Fox, Harry Quiney, Darren Lockie, et al.

    Objectives: Propagation-based phase-contrast computed tomography (PB-CT) is a new imaging technique that exploits refractive and absorption properties of X-rays to enhance soft tissue contrast and improve image quality. This study compares image quality of PB-CT and absorption-based CT (AB-CT) for breast imaging while exploring X-ray energy and radiation dose. Methods: Thirty-nine mastectomy samples were scanned at energy levels of 28-34keV using a flat panel detector at radiation dose levels of 4mGy and 2mGy. Image quality was assessed using signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), spatial resolution (res) and visibility (vis). Statistical analysis was performed to compare PB-CT images against their corresponding AB-CT images scanned at 32keV and 4mGy. Results: The PB-CT images at 4mGy, across nearly all energy levels, demonstrated superior image quality than AB-CT images at the same dose. At some energy levels, the 2mGy PB-CT images also showed better image quality in terms of CNR/Res and vis compared to the 4mGy AB-CT images. At both investigated doses, SNR and SNR/res were found to have a statistically significant difference across all energy levels. The difference in vis was statistically significant at some energy levels. Conclusion: This study demonstrates superior image quality of PB-CT over AB-CT, with X-ray energy playing a crucial role in determining image quality parameters. Advances in knowledge: Our findings reveal that standard dose PB-CT outperforms standard dose AB-CT across all image quality metrics. Additionally, we demonstrate that low dose PB-CT can produce superior images compared to standard dose AB-CT in terms of CNR/Res and vis.


  • Open Access

    Precise predictions and new insights for atomic ionisation from the Migdal effect

    by Peter Cox, Matthew J. Dolan, Christopher McCabe, Harry M. Quiney

    The scattering of neutral particles by an atomic nucleus can lead to electronic ionisation and excitation through a process known as the Migdal effect. We revisit and improve upon previous calculations of the Migdal effect, using the Dirac-Hartree-Fock method to calculate the atomic wavefunctions. Our methods do not rely on the use of the dipole approximation, allowing us to present robust results for higher nuclear recoil velocities than was previously possible. Our calculations provide the theoretical foundations for future measurements of the Migdal effect using neutron sources, and searches for dark matter in direct detection experiments. We show that multiple ionisation must be taken into account in experiments with fast neutrons, and derive the semi-inclusive probability for processes that yield a hard electron above a defined energy threshold. We present results for the noble elements up to and including xenon, as well as carbon, fluorine, silicon and germanium. The transition probabilities from our calculations are publicly available.

  • Open Access

    Precise predictions and new insights for atomic ionization from the Migdal effect

    by Peter Cox, Matthew J. Dolan, Christopher McCabe, Harry M. Quiney

    The scattering of neutral particles by an atomic nucleus can lead to electronic ionization and excitation through a process known as the Migdal effect. We revisit and improve upon previous calculations of the Migdal effect, using the Dirac-Hartree-Fock method to calculate the atomic wave functions. Our methods do not rely on the use of the dipole approximation, allowing us to present robust results for higher nuclear recoil velocities than was previously possible. Our calculations provide the theoretical foundations for future measurements of the Migdal effect using neutron sources, and searches for dark matter in direct detection experiments. We show that multiple ionization must be taken into account in experiments with fast neutrons, and derive the semi-inclusive probability for processes that yield a hard electron above a defined energy threshold. We present results for the noble elements up to and including xenon, as well as carbon, fluorine, silicon and germanium. The transition probabilities from our calculations are publicly available.


  • Open Access

    GRASP: The Future?

    by Ian Grant, Harry Quiney

    The theoretical foundations of relativistic electronic structure theory within quantum electrodynamics (QED) and the computational basis of the atomic structure code GRASP are briefly surveyed. A class of four-component basis set is introduced, which we denote the CKG-spinor set, that enforces the charge-conjugation symmetry of the Dirac equation. This formalism has been implemented using the Gaussian function technology that is routinely used in computational quantum chemistry, including in our relativistic molecular structure code, BERTHA. We demonstrate that, unlike the kinetically matched two-component basis sets that are widely employed in relativistic quantum chemistry, the CKG-spinor basis is able to reproduce the well-known eigenvalue spectrum of point-nuclear hydrogenic systems to high accuracy for all atomic symmetry types. Calculations are reported of third- and higher-order vacuum polarization effects in hydrogenic systems using the CKG-spinor set. These results reveal that Gaussian basis set expansions are able to calculate accurately these QED effects without recourse to the apparatus of regularization and in agreement with existing methods. An approach to the evaluation of the electron self-energy is outlined that extends our earlier work using partial-wave expansions in QED. Combined with the treatment of vacuum polarization effects described in this article, these basis set methods suggest the development of a comprehensive ab initio approach to the calculation of radiative and QED effects in future versions of the GRASP code.


  • Open Access

    GRASP: the Future!

    by Ian Grant, Harry M. Quiney

    Relativistic atomic and molecular structure calculations start from very different premises to quantum electrodynamics (QED). QED predicts radiative corrections that can nly be approximated crudely in today's atomic structure programs. This paper describes rigorous simple algorithms for including accurate vacuum polarization and self-energy corrections in the GRASP programs.


  • Open Access

    Observations of phase changes in monoolein during high viscous injection

    by Daniel J. Wells, Peter Berntsen, Eugeniu Balaur, Cameron M. Kewish, Patrick Adams, Andrew Aquila, Jack Binns, Sébastien Boutet, Hayden Broomhall, Carl Caleman, et al.

    Serial crystallography of membrane proteins often employs high-viscosity injectors (HVIs) to deliver micrometre-sized crystals to the X-ray beam. Typically, the carrier medium is a lipidic cubic phase (LCP) media, which can also be used to nucleate and grow the crystals. However, despite the fact that the LCP is widely used with HVIs, the potential impact of the injection process on the LCP structure has not been reported and hence is not yet well understood. The self-assembled structure of the LCP can be affected by pressure, dehydration and temperature changes, all of which occur during continuous flow injection. These changes to the LCP structure may in turn impact the results of X-ray diffraction measurements from membrane protein crystals. To investigate the influence of HVIs on the structure of the LCP we conducted a study of the phase changes in monoolein/water and monoolein/buffer mixtures during continuous flow injection, at both atmospheric pressure and under vacuum. The reservoir pressure in the HVI was tracked to determine if there is any correlation with the phase behaviour of the LCP. The results indicated that, even though the reservoir pressure underwent (at times) significant variation, this did not appear to correlate with observed phase changes in the sample stream or correspond to shifts in the LCP lattice parameter. During vacuum injection, there was a three-way coexistence of the gyroid cubic phase, diamond cubic phase and lamellar phase. During injection at atmospheric pressure, the coexistence of a cubic phase and lamellar phase in the monoolein/water mixtures was also observed. The degree to which the lamellar phase is formed was found to be strongly dependent on the co-flowing gas conditions used to stabilize the LCP stream. A combination of laboratory-based optical polarization microscopy and simulation studies was used to investigate these observations.