Sulaiman Ab Ghani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Sulaiman Ab Ghani has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Farook Ahmad
Pusat Pengajian Sains Kimia, Universiti Sains Malaysia, 11800 USM, Pulau Pinang, Malaysia
4 shared publicationsMartina Bainbridge
Department of Comparative Medicine, Brody School of Medicine, East Carolina University, Greenville, NC, USA
3 shared publicationsAhmad Pauzi Mohd Yusof
Pusat Pengajian Sains Farmasi, Universiti Sains Malaysia, 11800 USM, Pulau Pinang, Malaysia
2 shared publicationsAli Parsa
Pusat Pengajian Sains Kimia, Universiti Sains Malaysia, 11800 USM, Pulau Pinang, Malaysia
2 shared publicationsAmat Ngilmi Ahmad Sujari
Pusat Pengajian Sains Kimia, Universiti Sains Malaysia, 11800 USM, Pulau Pinang, Malaysia
2 shared publicationsQing-Gong Zhu
Pusat Pengajian Sains Kimia, Universiti Sains Malaysia, 11800 USM, Pulau Pinang, Malaysia
2 shared publications
Latest Publications
- 12 December 2012
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 160 (2) , B23-B29
MWCNT Modified Composite Pencil Graphite Electrodes Fabricated by Direct Dripping and Electrophoretic Deposition Methods: A Comparison Study
A comparative study of electrochemical sensors fabricated from composite pencil graphite (CPG) lead modified with carboxylic multi walled carbon nanotube (c-MWCNT) via direct dripping method (DM) and electrophoretic deposition (EPD) was carried out. DM was performed by adding a 2 μL c-MWCNT dispersion onto the surface of CPG electrode (CPGE), whilst EPD of c-MWCNT/CPGE was carried out at a constant applied potential of 25 V and deposition time of 1 min. The electrochemical performances of various modified CPGE have been characterized by cyclic voltammetry and electrochemical impedance spectroscopy (EIS) in Fe(CN)64-/3− redox system. The surface morphologies of the electrodes were studied by using field emission scanning electron microscopy (FESEM). Results showed that EPD deposited c-MWCNT is superior to DM due to its uniform c-MWCNT film and good electrochemical performances. The oxidation behavior of scopoletin on the c-MWCNT/CPGE made via EPD has also shown encouraging results.
- 12 December 2012
- Published by The Electrochemical Society in Journal of the Electrochemical Society
- Vol. 160 (2) , B23-B29
MWCNT Modified Composite Pencil Graphite Electrodes Fabricated by Direct Dripping and Electrophoretic Deposition Methods: A Comparison Study
A comparative study of electrochemical sensors fabricated from composite pencil graphite (CPG) lead modified with carboxylic multi walled carbon nanotube (c-MWCNT) via direct dripping method (DM) and electrophoretic deposition (EPD) was carried out. DM was performed by adding a 2 μL c-MWCNT dispersion onto the surface of CPG electrode (CPGE), whilst EPD of c-MWCNT/CPGE was carried out at a constant applied potential of 25 V and deposition time of 1 min. The electrochemical performances of various modified CPGE have been characterized by cyclic voltammetry and electrochemical impedance spectroscopy (EIS) in Fe(CN)64-/3− redox system. The surface morphologies of the electrodes were studied by using field emission scanning electron microscopy (FESEM). Results showed that EPD deposited c-MWCNT is superior to DM due to its uniform c-MWCNT film and good electrochemical performances. The oxidation behavior of scopoletin on the c-MWCNT/CPGE made via EPD has also shown encouraging results.
- Open Access
Flow Injection Analysis of Mercury Using 4-(Dimethylamino) Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire Electrode
A flow injection analysis (FIA) incorporating a thiosemicarbazone-based coated wire electrode (CWE) was developed method for the determination of mercury(II). A 0.1 M KNO3 carrier stream with pH between 1 and 5 and flow rate of 1 mL·min−1 were used as optimum parameters. A linear plot within the concentration range of 5 × 10−6–0.1 M Hg(II), slope of 27.8 ± 1 mV per decade and correlation coefficient (R2) of 0.984 were obtained. The system was successfully applied for the determination of mercury(II) in dental amalgam solutions and spiked environmental water samples. Highly reproducible measurements with relative standard deviation (RSD < 1% (n = 3)) were obtained, giving a typical throughput of 30 samples·h−1.
Open AccessFlow Injection Analysis of Mercury Using 4-(Dimethylamino) Benzaldehyde-4-Ethylthiosemicarbazone as the Ionophore of a Coated Wire Electrode
A flow injection analysis (FIA) incorporating a thiosemicarbazone-based coated wire electrode (CWE) was developed method for the determination of mercury(II). A 0.1 M KNO3 carrier stream with pH between 1 and 5 and flow rate of 1 mL·min−1 were used as optimum parameters. A linear plot within the concentration range of 5 × 10−6–0.1 M Hg(II), slope of 27.8 ± 1 mV per decade and correlation coefficient (R2) of 0.984 were obtained. The system was successfully applied for the determination of mercury(II) in dental amalgam solutions and spiked environmental water samples. Highly reproducible measurements with relative standard deviation (RSD < 1% (n = 3)) were obtained, giving a typical throughput of 30 samples·h−1.
- 19 October 2012
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 17 (3) , 681-690
Poly(4-vinylpyridine-co-aniline)-modified electrode—synthesis, characterization, and application as cadmium(II) ion sensor
- 19 October 2012
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 17 (3) , 681-690
Poly(4-vinylpyridine-co-aniline)-modified electrode—synthesis, characterization, and application as cadmium(II) ion sensor
- 11 May 2012
- Published by Wiley in Electroanalysis
- Vol. 24 (6) , 1463-1469
The 4‐(Dimethylamino) benzaldehyde‐4‐ethylthiosemicarbazone as Ionophore for Mercury(II) Solid State Selective Electrode
Hg(II) has formed a soluble complex with 4‐(dimethylamino) benzaldehyde‐4‐ethylthiosemicarbazone (DMABET) in methanol with a molar ratio of mercury(II):DMABET of 1 : 4. The formation constant (Kf) and Gibbs free energy (▵G) of the complex showed that the formation of the complex was favorable. The DMABET was investigated as ionophore for Hg(II)‐ion selective electrode (ISE). At optimum pH 1–5 the proposed Hg(II)‐ISE showed an almost Nernstian slope at 27.8±1 mV, with linear regression coefficient, R2=0.995 and a detection limit of 5×10−6 M. There was no serious interference from silver(I) with selectivity coefficient 5.69×10−3. The electrode life span was more than 3 months. It has been applied for real water sample analysis and the results were in good agreement with the standard method.
- 11 May 2012
- Published by Wiley in Electroanalysis
- Vol. 24 (6) , 1463-1469
The 4‐(Dimethylamino) benzaldehyde‐4‐ethylthiosemicarbazone as Ionophore for Mercury(II) Solid State Selective Electrode
Hg(II) has formed a soluble complex with 4‐(dimethylamino) benzaldehyde‐4‐ethylthiosemicarbazone (DMABET) in methanol with a molar ratio of mercury(II):DMABET of 1 : 4. The formation constant (Kf) and Gibbs free energy (▵G) of the complex showed that the formation of the complex was favorable. The DMABET was investigated as ionophore for Hg(II)‐ion selective electrode (ISE). At optimum pH 1–5 the proposed Hg(II)‐ISE showed an almost Nernstian slope at 27.8±1 mV, with linear regression coefficient, R2=0.995 and a detection limit of 5×10−6 M. There was no serious interference from silver(I) with selectivity coefficient 5.69×10−3. The electrode life span was more than 3 months. It has been applied for real water sample analysis and the results were in good agreement with the standard method.
- 9 May 2012
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 16 (10) , 3179-3187
Electrophoretic deposited MWCNT composite graphite pencils and its uses to determine hyperin
- 9 May 2012
- Published by Springer Nature in Journal of Solid State Electrochemistry
- Vol. 16 (10) , 3179-3187
Electrophoretic deposited MWCNT composite graphite pencils and its uses to determine hyperin
- Open Access
Ionophore-Based Potentiometric Sensors for the Flow-Injection Determination of Promethazine Hydrochloride in Pharmaceutical Formulations and Human Urine
Plasticised poly(vinyl chloride)-based membranes containing the ionophores (α-, β- and γ-cyclodextrins (CD), dibenzo-18-crown-6 (DB18C6) and dibenzo-30-crown-10 (DB30C10) were evaluated for their potentiometric response towards promethazine (PM) in a flow injection analysis (FIA) set-up. Good responses were obtained when β- and γ-CDs, and DB30C10 were used. The performance characteristics were further improved when tetrakis(4-chlorophenyl) borate (KTPB) was added to the membrane. The sensor based on β-CD, bis(2-ethylhexyl) adipate (BEHA) and KTPB exhibited the best performance among the eighteen sensor compositions that were tested. The response was linear from 1 x 10−5 to 1 x 10−2 M, slope was 61.3 mV decade−1, the pH independent region ranged from 4.5 to 7.0, a limit of detection of 5.3 x 10−6 M was possible and a lifetime of more than a month was observed when used in the FIA system. Other plasticisers such as dioctyl phenylphosphonate and tributyl phosphate do not show significant improvements in the quality of the sensors. The promising sensors were further tested for the effects of foreign ions (Li+, Na+, K+, Mg2+, Ca2+, Co2+, Cu2+, Cr3+, Fe3+, glucose, fructose). FIA conditions (e.g., effects of flow rate, injection volume, pH of the carrier stream) were also studied when the best sensor was used (based on β-CD). The sensor was applied to the determination of PM in four pharmaceutical preparations and human urine that were spiked with different levels of PM. Good agreement between the sensor and the manufacturer’s claimed values (for pharmaceutical preparations) was obtained, while mean recoveries of 98.6% were obtained for spiked urine samples. The molecular recognition features of the sensors as revealed by molecular modelling were rationalised by the nature of the interactions and complexation energies between the host and guest molecules.
Open AccessIonophore-Based Potentiometric Sensors for the Flow-Injection Determination of Promethazine Hydrochloride in Pharmaceutical Formulations and Human Urine
Plasticised poly(vinyl chloride)-based membranes containing the ionophores (α-, β- and γ-cyclodextrins (CD), dibenzo-18-crown-6 (DB18C6) and dibenzo-30-crown-10 (DB30C10) were evaluated for their potentiometric response towards promethazine (PM) in a flow injection analysis (FIA) set-up. Good responses were obtained when β- and γ-CDs, and DB30C10 were used. The performance characteristics were further improved when tetrakis(4-chlorophenyl) borate (KTPB) was added to the membrane. The sensor based on β-CD, bis(2-ethylhexyl) adipate (BEHA) and KTPB exhibited the best performance among the eighteen sensor compositions that were tested. The response was linear from 1 x 10−5 to 1 x 10−2 M, slope was 61.3 mV decade−1, the pH independent region ranged from 4.5 to 7.0, a limit of detection of 5.3 x 10−6 M was possible and a lifetime of more than a month was observed when used in the FIA system. Other plasticisers such as dioctyl phenylphosphonate and tributyl phosphate do not show significant improvements in the quality of the sensors. The promising sensors were further tested for the effects of foreign ions (Li+, Na+, K+, Mg2+, Ca2+, Co2+, Cu2+, Cr3+, Fe3+, glucose, fructose). FIA conditions (e.g., effects of flow rate, injection volume, pH of the carrier stream) were also studied when the best sensor was used (based on β-CD). The sensor was applied to the determination of PM in four pharmaceutical preparations and human urine that were spiked with different levels of PM. Good agreement between the sensor and the manufacturer’s claimed values (for pharmaceutical preparations) was obtained, while mean recoveries of 98.6% were obtained for spiked urine samples. The molecular recognition features of the sensors as revealed by molecular modelling were rationalised by the nature of the interactions and complexation energies between the host and guest molecules.
- 22 February 2010
- Published by Wiley in Electroanalysis
- Vol. 22 (5) , 549-555
The Electropolymerization of 2,6‐Diaminopyridine and Its Application as Mercury Ion Selective Electrode
- 22 February 2010
- Published by Wiley in Electroanalysis
- Vol. 22 (5) , 549-555
The Electropolymerization of 2,6‐Diaminopyridine and Its Application as Mercury Ion Selective Electrode
- 29 September 2009
- Published by Wiley in Fuel Cells
- Vol. 9 (5) , 579-587
The Nanocrystalline Nickel with Catalytic Properties on Methanol Oxidation in Alkaline Medium
The hexagonal closed packed (hcp) nanocrystalline nickel (Ni), with an average diameter of 9.7 ± 2.27 nm was deposited uniformly on composite graphite (CG) by the rapid scanning (6,500 mVs–1) voltammetry technique. The hcp‐nano Ni‐modified CG electrode was investigated for the catalytic oxidation of methanol in alkaline medium through the formation of NiOOH. A high anodic current was obtained at peak potential of +570 mV vs Ag/AgCl. Both the scan rate and the methanol concentration affected the oxidation of methanol. The results showed that catalytic activity had increased with decrease in Ni particle diameter. It was also shown that the hcp‐nano Ni/CG modified electrode was the most efficient catalyst in the oxidation of methanol.
- 29 September 2009
- Published by Wiley in Fuel Cells
- Vol. 9 (5) , 579-587
The Nanocrystalline Nickel with Catalytic Properties on Methanol Oxidation in Alkaline Medium
The hexagonal closed packed (hcp) nanocrystalline nickel (Ni), with an average diameter of 9.7 ± 2.27 nm was deposited uniformly on composite graphite (CG) by the rapid scanning (6,500 mVs–1) voltammetry technique. The hcp‐nano Ni‐modified CG electrode was investigated for the catalytic oxidation of methanol in alkaline medium through the formation of NiOOH. A high anodic current was obtained at peak potential of +570 mV vs Ag/AgCl. Both the scan rate and the methanol concentration affected the oxidation of methanol. The results showed that catalytic activity had increased with decrease in Ni particle diameter. It was also shown that the hcp‐nano Ni/CG modified electrode was the most efficient catalyst in the oxidation of methanol.
- Open Access
- 29 September 2009
- Published by Wiley in Fuel Cells
- Vol. 9 (5) , 761
The Nanocrystalline Nickel with Catalytic Properties on Methanol Oxidation in Alkaline Medium
- 29 September 2009
- Published by Wiley in Fuel Cells
- Vol. 9 (5) , 761
Open AccessThe Nanocrystalline Nickel with Catalytic Properties on Methanol Oxidation in Alkaline Medium