Ionophore-Based Potentiometric Sensors for the Flow-Injection Determination of Promethazine Hydrochloride in Pharmaceutical Formulations and Human Urine
Authors:
- Ahmed Khudhair HassanAHAhmed Khudhair Hassan
- Bahruddin SaadBSBahruddin Saad
- Sulaiman Ab GhaniSGSulaiman Ab Ghani
- Rohana AdnanRARohana Adnan
- Afidah Abdul RahimARAfidah Abdul Rahim
- Norariza AhmadNANorariza Ahmad
- Marina MokhtarMMMarina Mokhtar
- Suham Towfiq AmeenSASuham Towfiq Ameen
- Suad Mustafa Al-ArajiSASuad Mustafa Al-Araji
Open Access
- 18 January 2011
- Vol. 11 (1) , 1028-1042
Abstract
Plasticised poly(vinyl chloride)-based membranes containing the ionophores (α-, β- and γ-cyclodextrins (CD), dibenzo-18-crown-6 (DB18C6) and dibenzo-30-crown-10 (DB30C10) were evaluated for their potentiometric response towards promethazine (PM) in a flow injection analysis (FIA) set-up. Good responses were obtained when β- and γ-CDs, and DB30C10 were used. The performance characteristics were further improved when tetrakis(4-chlorophenyl) borate (KTPB) was added to the membrane. The sensor based on β-CD, bis(2-ethylhexyl) adipate (BEHA) and KTPB exhibited the best performance among the eighteen sensor compositions that were tested. The response was linear from 1 x 10−5 to 1 x 10−2 M, slope was 61.3 mV decade−1, the pH independent region ranged from 4.5 to 7.0, a limit of detection of 5.3 x 10−6 M was possible and a lifetime of more than a month was observed when used in the FIA system. Other plasticisers such as dioctyl phenylphosphonate and tributyl phosphate do not show significant improvements in the quality of the sensors. The promising sensors were further tested for the effects of foreign ions (Li+, Na+, K+, Mg2+, Ca2+, Co2+, Cu2+, Cr3+, Fe3+, glucose, fructose). FIA conditions (e.g., effects of flow rate, injection volume, pH of the carrier stream) were also studied when the best sensor was used (based on β-CD). The sensor was applied to the determination of PM in four pharmaceutical preparations and human urine that were spiked with different levels of PM. Good agreement between the sensor and the manufacturer’s claimed values (for pharmaceutical preparations) was obtained, while mean recoveries of 98.6% were obtained for spiked urine samples. The molecular recognition features of the sensors as revealed by molecular modelling were rationalised by the nature of the interactions and complexation energies between the host and guest molecules.Keywords
This publication has 38 references indexed in Scilit:
- Cyclodextrin-based potentiometric sensors for midazolam and diazepamJournal of Pharmaceutical and Biomedical Analysis, 2008
- New ionophores for vitamin B1 and vitamin B6 potentiometric sensors for multivitaminic controlJournal of Pharmaceutical and Biomedical Analysis, 2007
- Modern PotentiometryAngewandte Chemie International Edition, 2007
- Potentiometric sensors for trace-level analysisTrAC Trends in Analytical Chemistry, 2005
- Bead injection spectroscopy-flow injection analysis (BIS-FIA): an interesting tool applicable to pharmaceutical analysisJournal of Pharmaceutical and Biomedical Analysis, 2004
- Flow injection spectroelectroanalytical method for the determination of promethazine hydrochloride in pharmaceutical preparationsAnalytica Chimica Acta, 2003
- Voltammetric determination of chlorpromazine hydrochloride and promethazine hydrochloride with the use of multivariate calibrationAnalytica Chimica Acta, 2001
- Ionophore-based membrane electrodes: new analytical concepts and non-classical response mechanismsAnalytica Chimica Acta, 2000
- Paraquat sensors containing membrane components of high lipophilicitiesAnalytica Chimica Acta, 1997
- Spectrophotometric determination of promethazine by flow injection analysis and oxidation by CeIVJournal of Pharmaceutical and Biomedical Analysis, 1992