SLSamsun Lampotang

Samsun Lampotang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Samsun Lampotang has a total of 150 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Effect of catheter advancement technique on needle tip motion during peripheral intravenous insertion

    by Mayank Kotadia, S Hamad Sagheer, Christopher Samouce, Rachael Ahn, Hannah Kavelak, Samsun Lampotang, Nikolaus Gravenstein

    Background: Failure to successfully place a peripheral venous access device, also known as a peripheral intravenous catheter, impacts patient care, safety, and satisfaction. While factors like catheter size and insertion angle have been well studied, limited research has examined the influence of catheter advancement techniques on needle tip movement, a key determinant of successful placement and patient outcomes. This study measured needle tip movement during the initial advancement of the catheter off of the needle with three different techniques. Methods: In this prospective, within-subject crossover study at a single academic medical center, 78 clinicians each performed nine 18-gauge catheter advancements in randomized order, three per technique, into a hand phantom using one-handed self-advancement, two-handed self-advancement, and two-person advancement. Six-degree-of-freedom electromagnetic trackers (0.2 mm spatial resolution) captured needle tip kinematics and catheter advancement. Metrics measured were straight-line displacement, path length, maximum excursion, and the axial and radial components of motion for the first 1 cm of catheter advancement off of the needle. Results: Two-handed self-advancement yielded the lowest displacement (1.98 ± 1.14 mm), path length (3.93 ± 2.54 mm), and excursion (2.33 ± 1.21 mm). One-handed advancement produced larger displacement (2.54 ± 1.26 mm, p = 0.012), path length (9.23 ± 5.75 mm, p < 0.001), excursion (3.44 ± 1.70 mm, p = 0.002), and radial movement (0.74 ± 0.27 mm, p < 0.001 vs both other techniques). Two-person advancement matched two-handed lateral control but showed greater axial motion (1.65 ± 1.39 mm vs 0.78 ± 1.71 mm, p = 0.001) and slightly higher displacement (2.15 ± 1.17 mm). Participants perceived the highest ease of use and effectiveness was two-handed self-advancement. Conclusions: Two-handed self-advancement minimized unintended needle tip motion during initial catheter advancement off of the needle suggesting prioritization in training curricula. Reducing needle tip motion may lower endothelial injury and intravenous catheter advancement failure, supporting the need for clinical technique studies.

  • Training Programs for Thyroid Biopsy and Ablation: A Systematic Review

    by Sharon Bridgemohan, Andrea Ortiz, Gilberto Perez Rodriguez Garcia, Sannidhi Kolukula, Gonzalo J. Acosta, Christopher Samouce, Samsun Lampotang, Juan P. Brito, Naykky Singh Ospina


  • Aseptic non-touch technique training for ultrasound guided difficult peripheral vascular access: A prospective randomized study

    by Doğan Özen, Gökhan Arkaz, Kürşat Gümüş, Samsun Lampotang, Nikolaus Gravenstein, Chris Samouce, David Lizdas, Arvin W Trippensee, Robert Sarlay, Yahya Ayhan Acar, et al.

    Background: This study aims to evaluate the effectiveness of simulator-based repetitive training on the aseptic non-touch IV placement technique using an ultrasound-guided peripheral vascular access (USPVA) simulator among physicians working in the emergency department (ED), anesthesiology, and medical intensive care units (ICUs) at a tertiary training hospital. Methods: In this prospective randomized study, participants received theoretical training, then randomized into two groups and performed USPVA on the simulator. The simulated vessels were at 5, 10, and 15 mm depths with 2, 4, and 6 mm diameters, respectively. Finally, pre- and post-questionnaires and simulator data were analyzed. Results: A total of 36 physicians, (18 from ED, 9 from anesthesiology and 9 from ICU) participated in the study. Training on the simulator significantly improved the success rate of vascular access (62.5% (135/216)) compared to baseline values (31.9% (69/216); p < 0.001). There was a significant increase in the successful application of the aseptic non-touch technique after the training (96.2% (208/216)) compared to pre-training (42.5% (92/216); p < 0.001). The survey results showed that participants acquired new knowledge related to the aseptic non-touch technique through simulator-based training. Conclusion: This study demonstrates the successful implementation of aseptic non-touch technique for USPVA training for physicians using a mixed reality simulator.


  • A Portable Aspiration-Assisted Device for End-Cut Prostate Biopsy of Large Tissue Sample

    by Dane Ungurait, Roy Araya, Wayne Brisbane, Samsun Lampotang, Elisabeth Lawrence, Hitomi Yamaguchi

    Needle biopsy is a common procedure used to diagnose various types of cancer, particularly prostate cancer. Current needle biopsy devices used in this procedure feature End-Cut and Side-Cut needles. They typically have a spring-loaded firing mechanism that leaves uncertainty in controlling the needle position and can damage samples and tissues. Moreover, the sample orientation can be lost. In the Side-Cut needles, the needles cut and damage tissue beyond the sampling region, and the samples are smaller than those collected by End-Cut needles. This paper describes the design and development of a handheld aspiration-assisted device for End-Cut prostate biopsy using a direct current (DC) motor and a lead screw, which allows for better control of needle positioning and target throw length. During the biopsy procedure, the device drives at a constant speed toward the target position, cuts tissue, and utilizes vacuum pressure to retain that tissue. The mechanism helps collect samples while reducing damage to the tissue. Device performance was characterized by testing on ex vivo animal tissue and comparing the performance to two commercial biopsy devices currently used in clinical settings. The evaluation indices were sample mass and length relative to the devices’ throw lengths (End-Cut needle devices) or notch length (Side-Cut needle device). Tests performed on ex vivo bovine cardiac tissue indicated that the developed device collects larger samples compared to the commercial biopsy devices while providing the additional benefits of wider application, sample-orientation marking, and an easy-to-use design.

  • Development and Validation of a Mixed-Reality Simulator for Reducing Biopsy Core Deviation During Simulated Freehand Systematic Prostate Biopsy

    by Samsun PhD Lampotang, David E. Bs Lizdas, William T. Bs Johnson, Vincent Bs Mei, Jonathan Ba Wakim, XiangYang Lou, Anthony DeStephens, Yahya Acar, Louis Moy, Ardalanejaz Ahmad, et al.

    Introduction: We describe the development and validation of a mixed-reality prostate biopsy (PBx) simulator with built-in guidance aids and real-time 3-dimensional visualization. Methods: We evaluated our simulator during one-on-one training sessions with urology residents and attendings from 2018 to 2022. Participants performed freehand, side-fire, double-sextant transrectal ultrasound-guided systematic prostate biopsy (sPBx). After a baseline assessment (first set of 12 biopsy cores), participants trained for 25 minutes with visualization and cognitive aids activated. Training was followed by an exit set of 12 biopsy cores without visualization or cognitive aids and afterward, subjective assessment by trainees of the simulator. Deviation is the shortest distance of the center of a core from its intended template location. Results: Baseline deviations (mean ± SD) for residents (n = 24) and attendings (n = 4) were 13.4 ± 8.9 mm and 8.5 ± 3.6 mm (P < 0.001), respectively. Posttraining deviations were 8.7 ± 6.6 mm and 7.6 ± 3.7 mm (P = 0.271), respectively. Deviations between baseline and exit were decreased significantly for residents (P < 0.001) but not for attendings (P = 0.093). Overall feedback from participants was positive. Confidence in performing a PBx increased in novices after training (P = 0.011) and did not change among attendings (P = 0.180). Conclusions: A new PBx simulator can quantify and improve accuracy during simulated freehand sPBx while providing visualization and graphical feedback. Improved simulated sPBx accuracy could lead to more even distribution of biopsy cores within the prostate when performed in clinical settings, possibly reducing the high risk of missing an existing lesion and thus decreasing the time to initiating treatment, if indicated.


  • Open Access

    Impact of Simulation on Critical Care Fellows’ Electroencephalography Learning

    by Brenda G. Fahy, Samsun Lampotang, Jean E Cibula, W. Travis Johnson, Lou Ann Cooper, David Lizdas, Nikolaus Gravenstein, Terrie Vasilopoulos

    Continuous electroencephalography (EEG) is an important monitoring modality in the intensive care unit and a key skill for critical care fellows (CCFs) to learn. Our objective was to evaluate with CCFs an EEG educational curriculum on a web-based simulator. This prospective cohort study was conducted at a major academic medical center in Florida. After Institutional Review Board approval, 13 CCFs from anesthesiology, surgery, and pulmonary medicine consented to take an EEG curriculum. A 25-item EEG assessment was completed at baseline, after 10 EEG interpretations with a neurophysiologist, and after 10 clinically relevant EEG-based simulations providing clinical EEG interpretation hints. A 50-minute tutorial podcast was viewed after the baseline assessment. Main assessment outcomes included multiple outcomes related to web-based simulator performance: percent of hints used, percent of first words on EEG interpretation correct, and percent hint-based EEG interpretation score correct, with higher scores indicating more correct answers. Participants completed a 25-item EEG assessment before (baseline) and after the web-based simulator. All 13 CCFs completed the curriculum. Between scenarios, there were differences in percent of hints used (F9,108 = 11.7, p < 0.001), percent of first words correct (F9,108 = 13.6, p < 0.001), and overall percent hint-based score (F9,108 = 14.0, p < 0.001). Nonconvulsive status epilepticus had the lowest percent of hints used (15%) and the highest hint-based score (87%). Overall percent hint-based score (mean across all scenarios) was positively correlated with change in performance as the number of correct answers on the 25-item EEG assessment from before to after the web-based simulator activity (Spearman’s rho = 0.67, p = 0.023). A self-paced EEG interpretation curriculum involving a flipped classroom and screen-based simulation each requiring less than an hour to complete significantly improved CCF scores on the EEG assessment compared to baseline.


  • Open Access

    A Comparison of Central Venous Access to the Internal Jugular Vein and Two Standard Approaches to the Subclavian Vein: A Study of Cross-Sectional Areas Using Computed Tomography Scans

    by Joshua W. Sappenfield, Lou Ann Cooper, Robert Evans Heithaus, Samsun Lampotang

    The supraclavicular approach to the subclavian vein has been cited as having many advantages to the infraclavicular approach, including a larger short-axis cross-sectional area, a greater margin of safety, and fewer complications. To examine whether a larger short-axis cross-sectional area of the subclavian vein at the supraclavicular fossa is a potential explanation for the reduction in attempts with the supraclavicular approach seen in a previous study, we examined computed tomography scans from 50 patients (24 M, 26 F). The short-axis cross-sectional areas of the subclavian vein at the mid-clavicular line, the subclavian vein in the supraclavicular fossa, and the internal jugular vein at the level of the thyroid cartilage were calculated. The internal jugular vein short-axis cross-sectional area was significantly larger than the subclavian vein short-axis cross-sections measured at each location. We found no difference between the short-axis cross-sectional areas of the subclavian vein or when comparing measurements as a factor of gender, age, or race. Weight had a significant relationship to the short-axis cross-sectional area of the internal jugular vein and subclavian vein at the mid-clavicular vein. On supine computed tomographic imaging, the subclavian vein short-axis cross-section was not larger in the supraclavicular fossa than the mid-clavicular line. The short-axis cross-sectional area of the subclavian vein at the supraclavicular fossa does not appear to contribute to the decrease in attempts to access it. Weight, but not necessarily height, appears to be correlated with central vein size.


  • Manual Conservation of Supplemental Oxygen in Low-Resource Settings During the COVID-19 Pandemic

    by Samsun PhD Lampotang, Anthony DeStephens, Ilana Bs Zarour, David Bsme Lizdas, Nikolaus Gravenstein, William Bs Johnson, Yahya Acar, Jeffrey M. Md Feldman

    Summary Statement: Using a simulated adult COVID-19 patient with hypoxemia, we investigated whether caregivers interrupting oxygen flow by manually occluding oxygen tubing with pliers during exhalation can conserve oxygen while maintaining oxygenation. Oxygen pinching reduced oxygen use by 51% to 64%, maintained simulated oxygen saturation between 88% and 90%, and increased simulated average alveolar partial pressure of oxygen from a room air baseline of approximately 131 to 294–424 mm Hg compared with 607 mm Hg with 10 liters per minute (LPM) continuous oxygen flow. Simulation provided a methodology to rapidly evaluate a technique that has begun to be used with COVID-19 patients in low-resource environments experiencing an acute oxygen shortage.


  • Visualized Prostate Biopsy: An Intuitive Three-Dimensional User Interface for Systematic and Targeted Biopsy

    by Samsun Lampotang, Thomas Stringer, David E. Lizdas

    Background: Prostate biopsy false negative percentages are 21% to 47% and 16% to 30% for systematic and fused biopsy, respectively. An intuitive three-dimensional (3D) observed user interface may help reduce these percentages by providing real-time guidance and feedback during transrectal or transperineal biopsy. Materials and Methods: We track the moving prostate (including template locations and regions of interest), the transrectal ultrasound (TRUS) probe, and the biopsy device to construct a 3D environment. Users observe, aim, sample, and receive feedback in real time. Using a simulator with simulated TRUS , 48 participants performed freehand systematic prostate biopsy with traditional TRUS guidance and afterward with visualized prostate biopsy (vPBx). Results: During simulated biopsy, vPBx reduced the false negative percentage for a 0.5-mL spherical apical lesion from 52% to 2% ( p < 0.001). Conclusions: Preliminary results during simulated systematic biopsy warrant retrofitting the vPBx to actual TRUS equipment as a step toward clinical trials with patients.


  • Attitude is everything: keep probe pitch neutral during side‐fire prostate biopsy. A simulator study

    by Zhou Zhang, Samsun Lampotang, Yichao Yu, Yahya A. Acar, Jonathan Wakim, Vincent Mei, Ardalan E. Ahmad, Patrick Shenot, Jason Lee, Nathan Perlis, et al.

    Objectives: To develop and validate on a simulator a learnable technique to decrease deviation of biopsied cores from the template schema during freehand, side‐fire systematic prostate biopsy (sPBx) with the goal of reducing prostate biopsy (PBx) false‐negatives, thereby facilitating earlier sampling, diagnosis and treatment of clinically significant prostate cancer. Participants and Methods: Using a PBx simulator with real‐time three‐dimensional visualization, we devised a freehand, pitch‐neutral (0°, horizontal plane), side‐fire, transrectal ultrasonography (TRUS)‐guided sPBx technique in the left lateral decubitus position. Thirty‐four trainees on four Canadian and US urology programmes learned the technique on the same simulator, which recorded deviation from the intended template location in a double‐sextant template as well as the TRUS probe pitch at the time of sampling. We defined deviation as the shortest distance in millimeters between a core centre and its intended template location, template deviation as the mean of all deviations in a template, and mastery as achieving a template deviation ≤5.0 mm. Results: All results are reported as mean ± sd . The mean absolute pitch and template deviation before learning the technique (baseline) were 8.2 ± 4.1° and 8.0 ± 2.7 mm, respectively, and after mastering the technique decreased to 4.5 ± 2.7° ( P = 0.001) and 4.5 ± 0.6 mm ( P < 0.001). Template deviation was related to mean absolute pitch ( P < 0.001) and increased by 0.5 mm on average with each 1° increase in mean absolute pitch. Participants achieved mastery after practising 3.9 ± 2.9 double‐sextant sets. There was no difference in time to perform a double‐sextant set at baseline (277 ± 102 s) and mastery (283 ± 101 s; P = 0.39). Conclusion: A pitch‐neutral side‐fire technique reduced template deviation during simulated freehand TRUS‐guided sPBx, suggesting it may also reduce PBx false‐negatives in patients in a future clinical trial. This pitch‐neutral technique can be taught and learned; the University of Florida has been teaching it to all Urology residents for the last 2 years.