Effect of catheter advancement technique on needle tip motion during peripheral intravenous insertion
- 11 April 2026
- journal article
- Published by SAGE Publications in The Journal of Vascular Access
- Vol. 27 (5) , 2194-2203
Abstract
Background: Failure to successfully place a peripheral venous access device, also known as a peripheral intravenous catheter, impacts patient care, safety, and satisfaction. While factors like catheter size and insertion angle have been well studied, limited research has examined the influence of catheter advancement techniques on needle tip movement, a key determinant of successful placement and patient outcomes. This study measured needle tip movement during the initial advancement of the catheter off of the needle with three different techniques. Methods: In this prospective, within-subject crossover study at a single academic medical center, 78 clinicians each performed nine 18-gauge catheter advancements in randomized order, three per technique, into a hand phantom using one-handed self-advancement, two-handed self-advancement, and two-person advancement. Six-degree-of-freedom electromagnetic trackers (0.2 mm spatial resolution) captured needle tip kinematics and catheter advancement. Metrics measured were straight-line displacement, path length, maximum excursion, and the axial and radial components of motion for the first 1 cm of catheter advancement off of the needle. Results: Two-handed self-advancement yielded the lowest displacement (1.98 ± 1.14 mm), path length (3.93 ± 2.54 mm), and excursion (2.33 ± 1.21 mm). One-handed advancement produced larger displacement (2.54 ± 1.26 mm, p = 0.012), path length (9.23 ± 5.75 mm, p < 0.001), excursion (3.44 ± 1.70 mm, p = 0.002), and radial movement (0.74 ± 0.27 mm, p < 0.001 vs both other techniques). Two-person advancement matched two-handed lateral control but showed greater axial motion (1.65 ± 1.39 mm vs 0.78 ± 1.71 mm, p = 0.001) and slightly higher displacement (2.15 ± 1.17 mm). Participants perceived the highest ease of use and effectiveness was two-handed self-advancement. Conclusions: Two-handed self-advancement minimized unintended needle tip motion during initial catheter advancement off of the needle suggesting prioritization in training curricula. Reducing needle tip motion may lower endothelial injury and intravenous catheter advancement failure, supporting the need for clinical technique studies.Keywords
This publication has 32 references indexed in Scilit:
- Guidelines for Performing Ultrasound-Guided Vascular Cannulation: Recommendations of the American Society of EchocardiographyJournal of the American Society of Echocardiography, 2025
- Educational programs for implementing ultrasound guided peripheral intravenous catheter insertion in emergency departments: A systematic integrative literature reviewAustralasian Emergency Care, 2023
- Best practice in the use of peripheral venous catheters: A scoping review and expert consensusInfection Prevention in Practice, 2023
- Mechanism of pulsatile flushing technique for saline injection via a peripheral intravenous catheterClinical Biomechanics, 2020
- Better With UltrasoundChest, 2020
- The mechanistic causes of peripheral intravenous catheter failure based on a parametric computational studyScientific Reports, 2018
- Experimental study of needle–tissue interaction forces: Effect of needle geometries, insertion methods and tissue characteristicsJournal of Biomechanics, 2014
- Standard-length catheters vs long catheters in ultrasound-guided peripheral vein cannulationThe American Journal of Emergency Medicine, 2012
- A Randomized Controlled Trial Comparing One-Operator Versus Two-Operator Technique in Ultrasound-Guided Basilic Vein CannulationThe Journal of Emergency Medicine, 2008
- Effects of venous needle turbulence during ex vivo hemodialysis on endothelial morphology and nitric oxide formationJournal of Biomechanics, 2007