S. Smolek
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
S. Smolek has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Christina Streli
Atominstitut, TU Wien, Stadionallee 2, 1020 Vienna, Austria
3 shared publications P. Wobrauschek
3 shared publicationsA. Maderitsch
1 shared publicationA. Tabe
Department of Applied Chemistry & Bioengineering, Graduate School of Engineering Osaka City University 3‐3‐138, Sugimoto, Sumiyoshi Osaka 558‐8585 Japan
1 shared publicationB. Pemmer
Vienna University of Technology Atominstitut Stadionallee 2, 1020 Vienna, Austria
1 shared publicationK. Nakano
Department of Applied Chemistry & Bioengineering, Graduate School of Engineering Osaka City University 3‐3‐138, Sugimoto, Sumiyoshi Osaka 558‐8585 Japan
1 shared publication
Latest Publications
- 1 September 2014
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 99, 67-69
Feasibility study of total reflection X-ray fluorescence analysis using a liquid metal jet X-ray tube
- 1 September 2014
- Published by Elsevier in Spectrochimica Acta Part B: Atomic Spectroscopy
- Vol. 99, 67-69
Feasibility study of total reflection X-ray fluorescence analysis using a liquid metal jet X-ray tube
- Open Access
- 6 November 2013
- Published by Wiley in X-Ray Spectrometry
- Vol. 43 (2) , 93-101
Comparison of two confocal micro‐XRF spectrometers with different design aspects
Two different confocal micro X‐ray fluorescence spectrometers have been developed and installed at Osaka City University and the Vienna University of Technology Atominstitut. The Osaka City University system is a high resolution spectrometer operating in air. The Vienna University of Technology Atominstitut spectrometer has a lower spatial resolution but is optimized for light element detection and operates under vacuum condition. The performance of both spectrometers was compared. In order to characterize the spatial resolution, a set of nine specially prepared single element thin film reference samples (500 nm in thickness, Al, Ti, Cr, Fe Ni, Cu, Zr, Mo, and Au) was used. Lower limits of detection were determined using the National Institute of Standards and Technology standard reference material glass standard 1412. A paint layer sample (cultural heritage application) and paint on automotive steel samples were analyzed with both instruments. The depth profile information was acquired by scanning the sample perpendicular to the surface. © 2013 The Authors. X‐Ray Spectrometry published by John Wiley & Sons, Ltd.
- 6 November 2013
- Published by Wiley in X-Ray Spectrometry
- Vol. 43 (2) , 93-101
Open AccessComparison of two confocal micro‐XRF spectrometers with different design aspects
Two different confocal micro X‐ray fluorescence spectrometers have been developed and installed at Osaka City University and the Vienna University of Technology Atominstitut. The Osaka City University system is a high resolution spectrometer operating in air. The Vienna University of Technology Atominstitut spectrometer has a lower spatial resolution but is optimized for light element detection and operates under vacuum condition. The performance of both spectrometers was compared. In order to characterize the spatial resolution, a set of nine specially prepared single element thin film reference samples (500 nm in thickness, Al, Ti, Cr, Fe Ni, Cu, Zr, Mo, and Au) was used. Lower limits of detection were determined using the National Institute of Standards and Technology standard reference material glass standard 1412. A paint layer sample (cultural heritage application) and paint on automotive steel samples were analyzed with both instruments. The depth profile information was acquired by scanning the sample perpendicular to the surface. © 2013 The Authors. X‐Ray Spectrometry published by John Wiley & Sons, Ltd.
- Open Access
- 1 August 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (8) , 083703
Confocal micro-x-ray fluorescence spectrometer for light element analysis
An existing micro-x-ray fluorescence (micro-XRF) spectrometer designed for light element analysis (6 ≤ Z ≤ 14) has been extended to confocal geometry: a second polycapillary x-ray optic has been introduced in front of the energy dispersive x-ray detector. New piezo positioners for optimum alignment of both optics have been installed inside the vacuum chamber. The spectrometer offers now the possibility of true 3D elemental analysis in the micrometer regime. Depth resolution varies between 100 μm at 1 keV fluorescence energy (Na-Kα) and 30 μm for 17.5 keV (Mo). To further extend analytical capabilities a second x-ray tube with a Rh anode has been acquired to supplement to existing Mo anode tube. Lower limits of detection have been determined to be in the ppm region for confocal geometry. The spectrometer has been characterized and tested using different samples. Furthermore, results have been compared with SR micro-XRF to show the capabilities and limitations of this spectrometer.
- 1 August 2012
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 83 (8) , 083703
Open AccessConfocal micro-x-ray fluorescence spectrometer for light element analysis
An existing micro-x-ray fluorescence (micro-XRF) spectrometer designed for light element analysis (6 ≤ Z ≤ 14) has been extended to confocal geometry: a second polycapillary x-ray optic has been introduced in front of the energy dispersive x-ray detector. New piezo positioners for optimum alignment of both optics have been installed inside the vacuum chamber. The spectrometer offers now the possibility of true 3D elemental analysis in the micrometer regime. Depth resolution varies between 100 μm at 1 keV fluorescence energy (Na-Kα) and 30 μm for 17.5 keV (Mo). To further extend analytical capabilities a second x-ray tube with a Rh anode has been acquired to supplement to existing Mo anode tube. Lower limits of detection have been determined to be in the ppm region for confocal geometry. The spectrometer has been characterized and tested using different samples. Furthermore, results have been compared with SR micro-XRF to show the capabilities and limitations of this spectrometer.