A. Delcorte
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
A. Delcorte has a total of 29 co-authors. Here are the top co-authors by number of shared publications:
P. Bertrand
10 shared publicationsB.J. Garrison
Chemistry Department|Pennsylvania State University
3 shared publicationsJ.-F. Muller
Laboratoire de Spectrométrie de Masse et de Chimie Laser, Université de Metz, Boulevard Arago 1, F-57078, Metz, France
2 shared publicationsA. Felten
PCPM, Université Catholique de Louvain, Croix du Sud 1, B-1348 Louvain-la-Neuve, Belgium, and LISE, Facultés Universitaires Notre-Dame de la Paix, Namur, Belgium
1 shared publicationB. Arezki
PCPM, Université catholique de Louvain, 1 Croix du Sud, 1348 Louvain-la-Neuve, Belgium
1 shared publicationC. Poleunis
PCPM, Université Catholique de Louvain, Croix du Sud 1, B-1348 Louvain-la-Neuve, Belgium, and LISE, Facultés Universitaires Notre-Dame de la Paix, Namur, Belgium
1 shared publication
Latest Publications
- 1 August 2016
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 231, 520-528
Ni 0.9 Zn 0.1 O/ZnO nanocomposite prepared by malonate coprecipitation route for gas sensing
- 1 August 2016
- Published by Elsevier in Sensors and Actuators B: Chemical
- Vol. 231, 520-528
Ni 0.9 Zn 0.1 O/ZnO nanocomposite prepared by malonate coprecipitation route for gas sensing
- 1 February 2014
- Published by Elsevier in Applied Surface Science
- Vol. 293, 85-89
Dielectric breakdown during Cs+ sputtering of polyvinyl chloride
- 1 February 2014
- Published by Elsevier in Applied Surface Science
- Vol. 293, 85-89
Dielectric breakdown during Cs+ sputtering of polyvinyl chloride
- 1 December 2008
- Published by Elsevier in Applied Surface Science
- Vol. 255 (4) , 1229-1234
Sputtering of organic molecules by clusters, with focus on fullerenes
- 1 December 2008
- Published by Elsevier in Applied Surface Science
- Vol. 255 (4) , 1229-1234
Sputtering of organic molecules by clusters, with focus on fullerenes
- 7 April 2007
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (10) , 3673-3689
Metal-Assisted Secondary Ion Mass Spectrometry Using Atomic (Ga+, In+) and Fullerene Projectiles
The advantages and drawbacks of using either monatomic or buckminsterfullerene primary ions for metal-assisted secondary ion mass spectrometry (MetA-SIMS) are investigated using a series of organic samples including additive molecules, polyolefins, and small peptides. Gold deposition is mostly performed by sputter-coating, and in some cases, the results are compared to those of thermal evaporation (already used in a previous article: Delcorte, A.; Médard, N.; Bertrand, P. Anal. Chem. 2002, 74, 4955). The microstructure of the gold-covered sample surfaces is assessed by scanning and transmission electron microscopies. The merits of the different sets of experimental conditions are established via the analysis of fragment and parent-like ion yields. For most of the analyzed samples, the highest yields of fragment and parent-like ions are already reached with the sole use of C60+ projectiles. Metallization of the sample does not lead to a significant additional enhancement. For polyethylene and polypropylene, however, gold metallization associated with Ga+/In+ projectiles appears to be the only way to observe large cationized, sample-specific chain segments (m/z ∼ 1000−2000). A detailed study of the polypropylene mass spectra as a function of gold coverage shows that the dynamics of yield enhancement by metal nanoparticles is strongly dependent on the choice of the projectile, e.g., a pronounced increase with Ga+ and a slow decay with C60+. The cases of Irganox 1010, a polymer antioxidant, and leucine enkephalin, a small peptide, allow us to investigate the specific influence of the experimental conditions on the emission of parent(like) ions such as M+, (M + Na)+, and (M + Au)+. The results show a dependence on both the type of sample and the considered secondary ion. Using theoretical and experimental arguments, the discussion identifies some of the mechanisms underlying the general trends observed in the results. Guidelines concerning the choice of the experimental conditions for MetA-SIMS are provided.
- 7 April 2007
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 79 (10) , 3673-3689
Metal-Assisted Secondary Ion Mass Spectrometry Using Atomic (Ga+, In+) and Fullerene Projectiles
The advantages and drawbacks of using either monatomic or buckminsterfullerene primary ions for metal-assisted secondary ion mass spectrometry (MetA-SIMS) are investigated using a series of organic samples including additive molecules, polyolefins, and small peptides. Gold deposition is mostly performed by sputter-coating, and in some cases, the results are compared to those of thermal evaporation (already used in a previous article: Delcorte, A.; Médard, N.; Bertrand, P. Anal. Chem. 2002, 74, 4955). The microstructure of the gold-covered sample surfaces is assessed by scanning and transmission electron microscopies. The merits of the different sets of experimental conditions are established via the analysis of fragment and parent-like ion yields. For most of the analyzed samples, the highest yields of fragment and parent-like ions are already reached with the sole use of C60+ projectiles. Metallization of the sample does not lead to a significant additional enhancement. For polyethylene and polypropylene, however, gold metallization associated with Ga+/In+ projectiles appears to be the only way to observe large cationized, sample-specific chain segments (m/z ∼ 1000−2000). A detailed study of the polypropylene mass spectra as a function of gold coverage shows that the dynamics of yield enhancement by metal nanoparticles is strongly dependent on the choice of the projectile, e.g., a pronounced increase with Ga+ and a slow decay with C60+. The cases of Irganox 1010, a polymer antioxidant, and leucine enkephalin, a small peptide, allow us to investigate the specific influence of the experimental conditions on the emission of parent(like) ions such as M+, (M + Na)+, and (M + Au)+. The results show a dependence on both the type of sample and the considered secondary ion. Using theoretical and experimental arguments, the discussion identifies some of the mechanisms underlying the general trends observed in the results. Guidelines concerning the choice of the experimental conditions for MetA-SIMS are provided.
- 25 February 2005
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (7) , 2107-2115
Metal Salts for Molecular Ion Yield Enhancement in Organic Secondary Ion Mass Spectrometry: A Critical Assessment
In a search for molecular ion signal enhancement in organic SIMS, the efficiency of a series of organic and inorganic salts for molecular cationization has been tested using a panel of nonvolatile molecules with very different chemical characteristics (leucine enkephalin, Irganox 1010, tetraphenylnaphthalene, polystyrene). The compounds used for cationization include alkali bromide and group Ib metal salts (XBr with X = Li, Na, K; CF3CO2Ag; AgNO3; [CH3COCHC(O-)CH3]2Cu; AuCl3). Alkali ions, very good for polar molecule cationization, prove to be of limited interest for nonpolar molecules such as polystyrene. Silver trifluoroacetate displays excellent results for all the considered molecules, except for leucine enkephalin (which might be due to the use of different solvents for the analyte and the salt). Instead, silver nitrate mixed with leucine enkephalin in an ethanol solution provides intense molecular signals. The influence of the respective concentrations of analyte and salt in solution, of the silver trifluoroacetate solution stability, and of the sample microstructure on the secondary ion intensities are also investigated. The results of other combinations of analyte and salts are reported. Finally, the use of salts is critically compared to other sample preparation procedures previously proposed for SIMS analysis of large organic molecules.
- 25 February 2005
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 77 (7) , 2107-2115
Metal Salts for Molecular Ion Yield Enhancement in Organic Secondary Ion Mass Spectrometry: A Critical Assessment
In a search for molecular ion signal enhancement in organic SIMS, the efficiency of a series of organic and inorganic salts for molecular cationization has been tested using a panel of nonvolatile molecules with very different chemical characteristics (leucine enkephalin, Irganox 1010, tetraphenylnaphthalene, polystyrene). The compounds used for cationization include alkali bromide and group Ib metal salts (XBr with X = Li, Na, K; CF3CO2Ag; AgNO3; [CH3COCHC(O-)CH3]2Cu; AuCl3). Alkali ions, very good for polar molecule cationization, prove to be of limited interest for nonpolar molecules such as polystyrene. Silver trifluoroacetate displays excellent results for all the considered molecules, except for leucine enkephalin (which might be due to the use of different solvents for the analyte and the salt). Instead, silver nitrate mixed with leucine enkephalin in an ethanol solution provides intense molecular signals. The influence of the respective concentrations of analyte and salt in solution, of the silver trifluoroacetate solution stability, and of the sample microstructure on the secondary ion intensities are also investigated. The results of other combinations of analyte and salts are reported. Finally, the use of salts is critically compared to other sample preparation procedures previously proposed for SIMS analysis of large organic molecules.
- 25 May 2004
- Published by Elsevier in Applied Surface Science
- Vol. 231-232, 250-255
Interest of silver and gold metallization for molecular SIMS and SIMS imaging
- 25 May 2004
- Published by Elsevier in Applied Surface Science
- Vol. 231-232, 250-255
Interest of silver and gold metallization for molecular SIMS and SIMS imaging
- 1 May 2004
- Published by Elsevier in Applied Surface Science
Desorption/ionization of molecular nanoclusters: SIMS versus MALDI
- 1 May 2004
- Published by Elsevier in Applied Surface Science
Desorption/ionization of molecular nanoclusters: SIMS versus MALDI
- 1 May 2004
- Published by Elsevier in Applied Surface Science
Interest of silver and gold metallization for molecular SIMS and SIMS imaging
- 1 May 2004
- Published by Elsevier in Applied Surface Science
Interest of silver and gold metallization for molecular SIMS and SIMS imaging
- 18 November 2003
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 75 (24) , 6875-6885
Sample Metallization for Performance Improvement in Desorption/Ionization of Kilodalton Molecules: Quantitative Evaluation, Imaging Secondary Ion MS, and Laser Ablation
The metallization procedure, proposed recently for signal improvement in organic secondary ion mass spectrometry (SIMS) (Delcorte, A.; Médard, N.; Bertrand, P. Anal. Chem. 2002, 74, 4955)., has been thoroughly tested for a set of kilodalton molecules bearing various functional groups: Irganox 1010, polystyrene, polyalanine, and copper phthalocyanine. In addition to gold, we evaluate the effect of silver evaporation as a sample treatment prior to static SIMS analysis. Ion yields, damage cross sections, and emission efficiencies are compared for Ag- and Au-metallized molecular films, pristine coatings on silicon, and submonolayers of the same molecules adsorbed on silver and gold. The results are sample-dependent but as an example, the yield enhancement calculated for metallized Irganox films with respect to untreated coatings is larger than 2 orders of magnitude for the quasimolecular ion and a factor of 1−10 for characteristic fragments. Insights into the emission processes of quasimolecular ions from metallized surfaces are deduced from kinetic energy distribution measurements. The advantage of the method for imaging SIMS applications is illustrated by the study of a nonuniform coating of polystyrene oligomers on a 100-μm polypropylene film. The evaporated metal eliminates sample charging and allows us to obtain enhanced quality images of characteristic fragment ions as well as reasonably contrasted chemical mappings for cationized PS oligomers and large PP chain segments. Finally, we report on the benefit of using metal evaporation as a sample preparation procedure for laser ablation mass spectrometry. Our results show that the fingerprint spectra of Au-covered polystyrene, polypropylene, and Irganox films can be readily obtained under 337-nm irradiation, a wavelength for which the absorption of polyolefins is low. This is probably because the gold clusters embedded in the sample surface absorb and transfer the photon energy to the surrounding organic medium.
- 18 November 2003
- Published by American Chemical Society (ACS) in Analytical Chemistry
- Vol. 75 (24) , 6875-6885
Sample Metallization for Performance Improvement in Desorption/Ionization of Kilodalton Molecules: Quantitative Evaluation, Imaging Secondary Ion MS, and Laser Ablation
The metallization procedure, proposed recently for signal improvement in organic secondary ion mass spectrometry (SIMS) (Delcorte, A.; Médard, N.; Bertrand, P. Anal. Chem. 2002, 74, 4955)., has been thoroughly tested for a set of kilodalton molecules bearing various functional groups: Irganox 1010, polystyrene, polyalanine, and copper phthalocyanine. In addition to gold, we evaluate the effect of silver evaporation as a sample treatment prior to static SIMS analysis. Ion yields, damage cross sections, and emission efficiencies are compared for Ag- and Au-metallized molecular films, pristine coatings on silicon, and submonolayers of the same molecules adsorbed on silver and gold. The results are sample-dependent but as an example, the yield enhancement calculated for metallized Irganox films with respect to untreated coatings is larger than 2 orders of magnitude for the quasimolecular ion and a factor of 1−10 for characteristic fragments. Insights into the emission processes of quasimolecular ions from metallized surfaces are deduced from kinetic energy distribution measurements. The advantage of the method for imaging SIMS applications is illustrated by the study of a nonuniform coating of polystyrene oligomers on a 100-μm polypropylene film. The evaporated metal eliminates sample charging and allows us to obtain enhanced quality images of characteristic fragment ions as well as reasonably contrasted chemical mappings for cationized PS oligomers and large PP chain segments. Finally, we report on the benefit of using metal evaporation as a sample preparation procedure for laser ablation mass spectrometry. Our results show that the fingerprint spectra of Au-covered polystyrene, polypropylene, and Irganox films can be readily obtained under 337-nm irradiation, a wavelength for which the absorption of polyolefins is low. This is probably because the gold clusters embedded in the sample surface absorb and transfer the photon energy to the surrounding organic medium.