C. A. Malan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
C. A. Malan has a total of 6 co-authors. Here are the top co-authors by number of shared publications:
A. R. Wilkes
Senior Research Fellow
1 shared publicationA. Scholz
Consultant Anaesthetist, Department of Anaesthetics and Intensive Care Medicine, University Hospital of Wales, Cardiff, CF14 4XW, UK
1 shared publication- Antony R. Wilkes
Cardiff University, Cardiff, Wales, UK
1 shared publication C. Gildersleve
Department of Anaesthetics, University Hospital of Wales, Cardiff, UK
1 shared publicationJ. E. Hall
Reader, Department of Anaesthetics and Intensive Care Medicine, Wales College of Medicine, Cardiff University, Heath Park, Cardiff, CF14 4XN, UK
1 shared publicationM. A. Hampson
Laboratory Technician
1 shared publication
Latest Publications
- 7 December 2007
- Published by Wiley in Anaesthesia
- Vol. 63 (1) , 65-70
Minimum and optimum light requirements for laryngoscopy in paediatric anaesthesia: a manikin study*
Summary: Direct laryngoscopy is performed regularly in paediatric anaesthetic practice for the purpose of intubating a patient's trachea. A minimum illumination of 700 lux at a distance of 20 mm has been suggested in a draft standard for laryngoscopes from the International Organization for Standardization. We investigated the minimum and optimum illumination required by anaesthetists during laryngoscopy. Fifty anaesthetists were recruited to perform laryngoscopy on a child manikin with a selection of laryngoscope blades and bulbs attached to a variable voltage supply. There was a large variation in the illumination range of different bulb and blade combinations. We demonstrated a large interindividual variability between anaesthetists for illumination requirements during laryngoscopy. Anaesthetists can see the larynx at very low light levels, but optimum illumination was significantly greater than minimum illumination. Two of the six combinations could produce more than 700 lux. In all, 78% and 54% of anaesthetists considered 700 lux too bright with a halogen and xenon bulb, respectively. Our study suggests that the proposed standard of 700 lux may possibly be too bright.
- 7 December 2007
- Published by Wiley in Anaesthesia
- Vol. 63 (1) , 65-70
Minimum and optimum light requirements for laryngoscopy in paediatric anaesthesia: a manikin study*
Summary: Direct laryngoscopy is performed regularly in paediatric anaesthetic practice for the purpose of intubating a patient's trachea. A minimum illumination of 700 lux at a distance of 20 mm has been suggested in a draft standard for laryngoscopes from the International Organization for Standardization. We investigated the minimum and optimum illumination required by anaesthetists during laryngoscopy. Fifty anaesthetists were recruited to perform laryngoscopy on a child manikin with a selection of laryngoscope blades and bulbs attached to a variable voltage supply. There was a large variation in the illumination range of different bulb and blade combinations. We demonstrated a large interindividual variability between anaesthetists for illumination requirements during laryngoscopy. Anaesthetists can see the larynx at very low light levels, but optimum illumination was significantly greater than minimum illumination. Two of the six combinations could produce more than 700 lux. In all, 78% and 54% of anaesthetists considered 700 lux too bright with a halogen and xenon bulb, respectively. Our study suggests that the proposed standard of 700 lux may possibly be too bright.
- 1 December 2006
- Published by Wiley in Pediatric Anesthesia
- Vol. 16 (12) , 1298-1299
An evaluation of the filtration performance of paediatric breathing system filters using sodium chloride particles at low flows
- 1 December 2006
- Published by Wiley in Pediatric Anesthesia
- Vol. 16 (12) , 1298-1299
An evaluation of the filtration performance of paediatric breathing system filters using sodium chloride particles at low flows