Devin B. McCombie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Devin B. McCombie has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- Haruhiko Harry Asada
Massachusetts Institute of Technology
5 shared publications - Andrew T. Reisner
Department of Emergency Medicine, Massachusetts General Hospital, Boston, MA, USA
3 shared publications A.T. Reisner
1 shared publication- Andrew Reisner
Children’s Healthcare of Atlanta
1 shared publication - Andrew T. Reisner
Department of Emergency Medicine Massachusetts General Hospital Boston Massachusetts USA
1 shared publication H.H. Asada
1 shared publication
Latest Publications
- 17 April 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 18 (1) , 170-176
Identification of Multichannel Cardiovascular Dynamics Using Dual Laguerre Basis Functions for Noninvasive Cardiovascular Monitoring
This paper presents a novel method to identify the cardiovascular (CV) system using two distinct peripheral blood pressure (BP) signals. The method can characterize the distinct arterial path dynamics that shape each of the BP signals and recover the common central-flow signal fed to them. A Laguerre series data-compression technique is used to obtain a compact representation of the CV system, whose coefficients are identified using the multichannel blind system identification. A Laguerre model deconvolution algorithm is developed to stably recover the central-flow signal. Persistent excitation, model identifiability, and asymptotic variance are analyzed to quantify the method's validity and reliability, without using any direct measurement of central-flow input signal. Experimental results based on 7000 data segments obtained from nine swine subjects show that, for all the swine subjects under diverse physiologic conditions, the CV dynamics can be identified very reliably and the waveform of the central flow can be recovered stably from peripheral BP signals.
- 17 April 2009
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Control Systems Technology
- Vol. 18 (1) , 170-176
Identification of Multichannel Cardiovascular Dynamics Using Dual Laguerre Basis Functions for Noninvasive Cardiovascular Monitoring
This paper presents a novel method to identify the cardiovascular (CV) system using two distinct peripheral blood pressure (BP) signals. The method can characterize the distinct arterial path dynamics that shape each of the BP signals and recover the common central-flow signal fed to them. A Laguerre series data-compression technique is used to obtain a compact representation of the CV system, whose coefficients are identified using the multichannel blind system identification. A Laguerre model deconvolution algorithm is developed to stably recover the central-flow signal. Persistent excitation, model identifiability, and asymptotic variance are analyzed to quantify the method's validity and reliability, without using any direct measurement of central-flow input signal. Experimental results based on 7000 data segments obtained from nine swine subjects show that, for all the swine subjects under diverse physiologic conditions, the CV dynamics can be identified very reliably and the waveform of the central flow can be recovered stably from peripheral BP signals.
- 1 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 989-992
Motion based adaptive calibration of pulse transit time measurements to arterial blood pressure for an autonomous, wearable blood pressure monitor
This paper presents a novel adaptive algorithm for calibrating non-invasive pulse transit time (PTT) measurements to arterial blood pressure (BP). This new algorithm allows complete calibration of PTT to BP without the use of an oscillometric blood pressure cuff or external pressure sensor. Further, the algorithm can be used to continually update the identified parameters in the calibration equation while the patient is wearing the device. The technique utilizes natural patient motion to generate a known change in the transmural pressure (input) acting on the arteries monitored by our device to produce a measurable change in pulse transit time (output). The natural motion includes varying the height of the sensor relative to the heart to alter hydrostatic pressure at the measurement site and adjusting proximal joint posture to vary the external arterial pressure at the measurement site. This new algorithm is applied to a unique wearable sensor architecture that combines two in-line PPG sensors, one located at the ulnar artery of the wrist and one located at the digital artery of the little finger along with a multi-axis accelerometer for height measurement. Initial human subject tests results using the new algorithm and device will be presented.
- 1 August 2008
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 2008 (1094687X) , 989-992
Motion based adaptive calibration of pulse transit time measurements to arterial blood pressure for an autonomous, wearable blood pressure monitor
This paper presents a novel adaptive algorithm for calibrating non-invasive pulse transit time (PTT) measurements to arterial blood pressure (BP). This new algorithm allows complete calibration of PTT to BP without the use of an oscillometric blood pressure cuff or external pressure sensor. Further, the algorithm can be used to continually update the identified parameters in the calibration equation while the patient is wearing the device. The technique utilizes natural patient motion to generate a known change in the transmural pressure (input) acting on the arteries monitored by our device to produce a measurable change in pulse transit time (output). The natural motion includes varying the height of the sensor relative to the heart to alter hydrostatic pressure at the measurement site and adjusting proximal joint posture to vary the external arterial pressure at the measurement site. This new algorithm is applied to a unique wearable sensor architecture that combines two in-line PPG sensors, one located at the ulnar artery of the wrist and one located at the digital artery of the little finger along with a multi-axis accelerometer for height measurement. Initial human subject tests results using the new algorithm and device will be presented.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 370-373
Adaptive hydrostatic blood pressure calibration: Development of a wearable, autonomous pulse wave velocity blood pressure monitor
A technique for calibrating non-invasive peripheral arterial sensor signals to peripheral arterial blood pressure (BP) is proposed. The adaptive system identification method utilizes a measurable intra-arterial hydrostatic pressure change in the sensor outfitted appendage to identify the transduction dynamics relating the peripheral arterial blood pressure and the measured arterial sensor signal. The proposed algorithm allows identification of the calibration dynamics despite unknown physiologic fluctuations in arterial pressure during the calibration period under certain prescribed conditions. By employing unique wearable sensor architecture to estimate pulse wave velocity (PWV), this technique is used to calibrate peripheral pulse transit time measurements to arterial blood pressure. This sensor architecture is comprised of two inline photoplethysmograph sensors one in the form of a wristwatch measuring the pulse waveform in the ulnar artery and one in the form of a ring measuring the pulse waveform from the digital artery along the base of the little finger. Experimental results using the proposed algorithm to calibrate PTT to BP on human subjects will be presented.
- 1 August 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2007 (1094687X) , 370-373
Adaptive hydrostatic blood pressure calibration: Development of a wearable, autonomous pulse wave velocity blood pressure monitor
A technique for calibrating non-invasive peripheral arterial sensor signals to peripheral arterial blood pressure (BP) is proposed. The adaptive system identification method utilizes a measurable intra-arterial hydrostatic pressure change in the sensor outfitted appendage to identify the transduction dynamics relating the peripheral arterial blood pressure and the measured arterial sensor signal. The proposed algorithm allows identification of the calibration dynamics despite unknown physiologic fluctuations in arterial pressure during the calibration period under certain prescribed conditions. By employing unique wearable sensor architecture to estimate pulse wave velocity (PWV), this technique is used to calibrate peripheral pulse transit time measurements to arterial blood pressure. This sensor architecture is comprised of two inline photoplethysmograph sensors one in the form of a wristwatch measuring the pulse waveform in the ulnar artery and one in the form of a ring measuring the pulse waveform from the digital artery along the base of the little finger. Experimental results using the proposed algorithm to calibrate PTT to BP on human subjects will be presented.
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2006 (1557170X) , 3521-3524
Adaptive blood pressure estimation from wearable PPG sensors using peripheral artery pulse wave velocity measurements and multi-channel blind identification of local arterial dynamics
A method for estimating pulse wave velocity (PWV) using circulatory waveform signals derived from multiple photoplethysmograph (PPG) sensors is described. The method employs two wearable in-line PPG sensors placed at a known distance from one another at the ulnar and digital artery. A technique for calibrating the measured pulse wave velocity to arterial blood pressure using hydrostatic pressure variation is presented. Additionally, a framework is described for estimating local arterial dynamics using PPG waveforms and multi-channel blind system ID. Initial results implementing the method on data derived from a human subject at different arterial pressures is presented. Results show that the method is capable of measuring the changes in arterial PWV that result from fluctuations in mean arterial pressure
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2006 (1557170X) , 3521-3524
Adaptive blood pressure estimation from wearable PPG sensors using peripheral artery pulse wave velocity measurements and multi-channel blind identification of local arterial dynamics
A method for estimating pulse wave velocity (PWV) using circulatory waveform signals derived from multiple photoplethysmograph (PPG) sensors is described. The method employs two wearable in-line PPG sensors placed at a known distance from one another at the ulnar and digital artery. A technique for calibrating the measured pulse wave velocity to arterial blood pressure using hydrostatic pressure variation is presented. Additionally, a framework is described for estimating local arterial dynamics using PPG waveforms and multi-channel blind system ID. Initial results implementing the method on data derived from a human subject at different arterial pressures is presented. Results show that the method is capable of measuring the changes in arterial PWV that result from fluctuations in mean arterial pressure
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 3521-3524
Adaptive blood pressure estimation from wearable PPG sensors using peripheral artery pulse wave velocity measurements and multi-channel blind identification of local arterial dynamics
A method for estimating pulse wave velocity (PWV) using circulatory waveform signals derived from multiple photoplethysmograph (PPG) sensors is described. The method employs two wearable in-line PPG sensors placed at a known distance from one another at the ulnar and digital artery. A technique for calibrating the measured pulse wave velocity to arterial blood pressure using hydrostatic pressure variation is presented. Additionally, a framework is described for estimating local arterial dynamics using PPG waveforms and multi-channel blind system ID. Initial results implementing the method on data derived from a human subject at different arterial pressures is presented. Results show that the method is capable of measuring the changes in arterial PWV that result from fluctuations in mean arterial pressure
- 1 August 2006
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 1557170X,p. 3521-3524
Adaptive blood pressure estimation from wearable PPG sensors using peripheral artery pulse wave velocity measurements and multi-channel blind identification of local arterial dynamics
A method for estimating pulse wave velocity (PWV) using circulatory waveform signals derived from multiple photoplethysmograph (PPG) sensors is described. The method employs two wearable in-line PPG sensors placed at a known distance from one another at the ulnar and digital artery. A technique for calibrating the measured pulse wave velocity to arterial blood pressure using hydrostatic pressure variation is presented. Additionally, a framework is described for estimating local arterial dynamics using PPG waveforms and multi-channel blind system ID. Initial results implementing the method on data derived from a human subject at different arterial pressures is presented. Results show that the method is capable of measuring the changes in arterial PWV that result from fluctuations in mean arterial pressure
- 17 October 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 52 (11) , 1889-1901
Laguerre-Model Blind System Identification: Cardiovascular Dynamics Estimated From Multiple Peripheral Circulatory Signals
This paper presents a method for comparing multiple circulatory waveforms measured at different locations to improve cardiovascular parameter estimation from these signals. The method identifies the distinct vascular dynamics that shape each waveform signal, and estimates the common cardiac flow input shared by them. This signal-processing algorithm uses the Laguerre function series expansion for modeling the hemodynamics of each arterial branch, and identifies unknown parameters in these models from peripheral waveforms using multichannel blind system identification. An effective technique for determining the Laguerre base pole is developed, so that the Laguerre expansion captures and quickly converges to the intrinsic arterial dynamics observed in the two circulatory signals. Furthermore, a novel deconvolution method is developed in order to stably invert the identified dynamic models for estimating the cardiac output (CO) waveform from peripheral pressure waveforms. The method is applied to experimental swine data. A mean error of less than 5% with the measured peripheral pressure waveforms has been achieved using the models and excellent agreement between the estimated CO waveforms and the gold standard measurements have been obtained.
- 17 October 2005
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Biomedical Engineering
- Vol. 52 (11) , 1889-1901
Laguerre-Model Blind System Identification: Cardiovascular Dynamics Estimated From Multiple Peripheral Circulatory Signals
This paper presents a method for comparing multiple circulatory waveforms measured at different locations to improve cardiovascular parameter estimation from these signals. The method identifies the distinct vascular dynamics that shape each waveform signal, and estimates the common cardiac flow input shared by them. This signal-processing algorithm uses the Laguerre function series expansion for modeling the hemodynamics of each arterial branch, and identifies unknown parameters in these models from peripheral waveforms using multichannel blind system identification. An effective technique for determining the Laguerre base pole is developed, so that the Laguerre expansion captures and quickly converges to the intrinsic arterial dynamics observed in the two circulatory signals. Furthermore, a novel deconvolution method is developed in order to stably invert the identified dynamic models for estimating the cardiac output (CO) waveform from peripheral pressure waveforms. The method is applied to experimental swine data. A mean error of less than 5% with the measured peripheral pressure waveforms has been achieved using the models and excellent agreement between the estimated CO waveforms and the gold standard measurements have been obtained.