Chen‐Shou Chui
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Chen‐Shou Chui has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
Linda Hong
3 shared publications- Beryl McCormick
Memorial Sloan Kettering Cancer Center
2 shared publications Ellen Yorke
2 shared publications- Maria F. Chan
Memorial Sloan Kettering Cancer Center
2 shared publications - Spiridon V. Spirou
Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY, USA
2 shared publications - Albert Y. C. Fung
Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, 1275 York Avenue, New York, New York 10021, USA
1 shared publication
Latest Publications
- 1 July 2005
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 62 (4) , 1217-1223
Intensity-modulated radiotherapy technique for three-field breast treatment
- 1 July 2005
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 62 (4) , 1217-1223
Intensity-modulated radiotherapy technique for three-field breast treatment
- 25 June 2003
- Published by Wiley in Medical Physics
- Vol. 30 (7) , 1736-1746
The effects of intra‐fraction organ motion on the delivery of intensity‐modulated field with a multileaf collimator
Intensity‐modulated radiation therapy can be conveniently delivered with a multileaf collimator. With this method, the entire field is not delivered at once, but rather it is composed of many subfields defined by the leaf positions as a function of beam on time. At any given instant, only these subfields are delivered. During treatment, if the organ moves, part of the volume may move in or out of these subfields. Due to this interplay between organ motion and leaf motion the delivered dose may be different from what was planned. In this work, we present a method that calculates the effects of organ motion on delivered dose. The direction of organ motion may be parallel or perpendicular to the leaf motion, and the effect can be calculated for a single fraction or for multiple fractions. Three breast patients and four lung patients were included in this study, with the amplitude of the organ motion varying from to and the period varying from 4 to 8 seconds. Calculations were made for these patients with and without organ motion, and results were examined in terms of isodose distribution and dose volume histograms. Each calculation was repeated ten times in order to estimate the statistical uncertainties. For selected patients, calculations were also made with conventional treatment technique. The effects of organ motion on conventional techniques were compared relative to that on IMRT techniques. For breast treatment, the effect of organ motion primarily broadened the penumbra at the posterior field edge. The dose in the rest of the treatment volume was not significantly affected. For lung treatment, the effect also broadened the penumbra and degraded the coverage of the planning target volume (PTV). However, the coverage of the clinical target volume (CTV) was not much affected, provided the PTV margin was adequate. The same effects were observed for both IMRT and conventional treatment techniques. For the IMRT technique, the standard deviations of ten samples of a 30‐fraction calculation were very small for all patients, implying that over a typical treatment course of 30 fractions, the delivered dose was very close to the expected value. Hence, under typical clinical conditions, the effect of organ motion on delivered dose can be calculated without considering the interplay between the organ motion and the leaf motion. It can be calculated as the weighted average of the dose distribution without organ motion with the distribution of organ motion. Since the effects of organ motion on dose were comparable for both IMRT and conventional techniques, the PTV margin should remain the same for both techniques.
- 25 June 2003
- Published by Wiley in Medical Physics
- Vol. 30 (7) , 1736-1746
The effects of intra‐fraction organ motion on the delivery of intensity‐modulated field with a multileaf collimator
Intensity‐modulated radiation therapy can be conveniently delivered with a multileaf collimator. With this method, the entire field is not delivered at once, but rather it is composed of many subfields defined by the leaf positions as a function of beam on time. At any given instant, only these subfields are delivered. During treatment, if the organ moves, part of the volume may move in or out of these subfields. Due to this interplay between organ motion and leaf motion the delivered dose may be different from what was planned. In this work, we present a method that calculates the effects of organ motion on delivered dose. The direction of organ motion may be parallel or perpendicular to the leaf motion, and the effect can be calculated for a single fraction or for multiple fractions. Three breast patients and four lung patients were included in this study, with the amplitude of the organ motion varying from to and the period varying from 4 to 8 seconds. Calculations were made for these patients with and without organ motion, and results were examined in terms of isodose distribution and dose volume histograms. Each calculation was repeated ten times in order to estimate the statistical uncertainties. For selected patients, calculations were also made with conventional treatment technique. The effects of organ motion on conventional techniques were compared relative to that on IMRT techniques. For breast treatment, the effect of organ motion primarily broadened the penumbra at the posterior field edge. The dose in the rest of the treatment volume was not significantly affected. For lung treatment, the effect also broadened the penumbra and degraded the coverage of the planning target volume (PTV). However, the coverage of the clinical target volume (CTV) was not much affected, provided the PTV margin was adequate. The same effects were observed for both IMRT and conventional treatment techniques. For the IMRT technique, the standard deviations of ten samples of a 30‐fraction calculation were very small for all patients, implying that over a typical treatment course of 30 fractions, the delivered dose was very close to the expected value. Hence, under typical clinical conditions, the effect of organ motion on delivered dose can be calculated without considering the interplay between the organ motion and the leaf motion. It can be calculated as the weighted average of the dose distribution without organ motion with the distribution of organ motion. Since the effects of organ motion on dose were comparable for both IMRT and conventional techniques, the PTV margin should remain the same for both techniques.
- 19 March 2002
- Published by Wiley in Medical Physics
- Vol. 29 (4) , 522-529
A simplified intensity modulated radiation therapy technique for the breast
A simplified intensity modulated radiation therapy (sIMRT) technique for the breast is presented. The technique aims to produce a uniform dose distribution in the entire breast volume. Using the standard tangential beam arrangement, we first determine for each pencil beam the midpoint of the segment that intersects the treatment volume. The dose to the midpoint from the open field is then calculated. The intensity of the pencil beam is determined as proportional to the inverse of the open field dose. With this intensity modulated beam, the dose delivered to the midpoint of each pencil beam segment that intersects the treatment volume is now equalized. The dose distribution in the entire treatment volume is nearly as uniform as can be achieved under the given beam arrangement. Fifteen left breast patients were planned with the sIMRT technique. For comparison, the same group of patients was also planned with the standard wedged pair technique and the full‐fledged volume‐based IMRT (vIMRT) technique. Both the sIMRT and the vIMRT techniques achieved more homogeneous dose in the treatment volume than the standard plan. Doses to the heart, the ipsilateral lung, and the contralateral breast were also reduced. The planning time and the treatment time for the sIMRT technique were comparable to that of the standard technique, and significantly less than that required by the vIMRT technique. The sIMRT technique is practical for large‐scale implementation in a busy clinic without requiring significant increase of resources.
- 19 March 2002
- Published by Wiley in Medical Physics
- Vol. 29 (4) , 522-529
A simplified intensity modulated radiation therapy technique for the breast
A simplified intensity modulated radiation therapy (sIMRT) technique for the breast is presented. The technique aims to produce a uniform dose distribution in the entire breast volume. Using the standard tangential beam arrangement, we first determine for each pencil beam the midpoint of the segment that intersects the treatment volume. The dose to the midpoint from the open field is then calculated. The intensity of the pencil beam is determined as proportional to the inverse of the open field dose. With this intensity modulated beam, the dose delivered to the midpoint of each pencil beam segment that intersects the treatment volume is now equalized. The dose distribution in the entire treatment volume is nearly as uniform as can be achieved under the given beam arrangement. Fifteen left breast patients were planned with the sIMRT technique. For comparison, the same group of patients was also planned with the standard wedged pair technique and the full‐fledged volume‐based IMRT (vIMRT) technique. Both the sIMRT and the vIMRT techniques achieved more homogeneous dose in the treatment volume than the standard plan. Doses to the heart, the ipsilateral lung, and the contralateral breast were also reduced. The planning time and the treatment time for the sIMRT technique were comparable to that of the standard technique, and significantly less than that required by the vIMRT technique. The sIMRT technique is practical for large‐scale implementation in a busy clinic without requiring significant increase of resources.
- 11 December 2001
- Published by Wiley in Medical Physics
- Vol. 28 (12) , 2441-2449
Delivery of intensity‐modulated radiation therapy with a conventional multileaf collimator: Comparison of dynamic and segmental methods
Intensity-modulated radiation therapy(IMRT) can be delivered with a conventional multileaf collimator(MLC), either in dynamic mode (DMLC) or in segmental mode (SMLC, also known as “step-and-shoot”). The advantage of DMLC is its ability to deliver the desired intensity profile produced by inverse planning with a high degree of fidelity. The SMLC method, on the other hand, resembles treatment with multiple static fields, and can be more easily verified. However, the use of SMLC requires that the desired profile be approximated by discrete levels of intensity, which may lead to degradation in the delivereddose distribution. Clearly, the results of SMLC delivery depend on the number of levels and the spatial resolution of the intensity distribution. In this work, we compare the DMLC method and the SMLC method employing different numbers of levels and different spatial resolutions. Three disease sites were studied: prostate, nasopharynx, and breast, with three cases for each. In general, a 5- to 10-level SMLC plan produced results comparable to that from a DMLC plan. The target coverage is improved by increasing the number of levels while critical organs are better protected with finer spatial resolutions. The beam-on-time (MUs) requirement for SMLC was approximately 20% less than DMLC, but the delivery time (in minutes) was about twice as long. Thus, the choice depends on many factors including machine capability, quality assurance, target coverage, critical organ protection, beam-on-time, delivery time, and other clinical considerations.
- 11 December 2001
- Published by Wiley in Medical Physics
- Vol. 28 (12) , 2441-2449
Delivery of intensity‐modulated radiation therapy with a conventional multileaf collimator: Comparison of dynamic and segmental methods
Intensity-modulated radiation therapy(IMRT) can be delivered with a conventional multileaf collimator(MLC), either in dynamic mode (DMLC) or in segmental mode (SMLC, also known as “step-and-shoot”). The advantage of DMLC is its ability to deliver the desired intensity profile produced by inverse planning with a high degree of fidelity. The SMLC method, on the other hand, resembles treatment with multiple static fields, and can be more easily verified. However, the use of SMLC requires that the desired profile be approximated by discrete levels of intensity, which may lead to degradation in the delivereddose distribution. Clearly, the results of SMLC delivery depend on the number of levels and the spatial resolution of the intensity distribution. In this work, we compare the DMLC method and the SMLC method employing different numbers of levels and different spatial resolutions. Three disease sites were studied: prostate, nasopharynx, and breast, with three cases for each. In general, a 5- to 10-level SMLC plan produced results comparable to that from a DMLC plan. The target coverage is improved by increasing the number of levels while critical organs are better protected with finer spatial resolutions. The beam-on-time (MUs) requirement for SMLC was approximately 20% less than DMLC, but the delivery time (in minutes) was about twice as long. Thus, the choice depends on many factors including machine capability, quality assurance, target coverage, critical organ protection, beam-on-time, delivery time, and other clinical considerations.
- 1 June 2001
- Published by Elsevier in Medical Dosimetry
- Vol. 26 (2) , 189-197
Inverse planning algorithms for external beam radiation therapy
- 1 June 2001
- Published by Elsevier in Medical Dosimetry
- Vol. 26 (2) , 189-197
Inverse planning algorithms for external beam radiation therapy
- Open Access
- 1 March 2001
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 2 (2) , 85-89
The measurement of three dimensional dose distribution of a ruthenium‐106 ophthalmological applicator using magnetic resonance imaging of BANG polymer gels1
The BANG (MGS Research Inc., Guilford, CT) polymer gel has been used as a dosimeter to determine the three‐dimensional (3D) dose distribution of a ruthenium‐106 (Ru‐106) ophthalmologic applicator. An eye phantom made of the BANG gel was irradiated with the Ru‐106 source for up to 1 h. The phantom and a set of calibration vials were scanned simultaneously in a GE 1.5 T MR imager using the Hahn spin‐echo pulse sequence with a TR of 2000 ms and two TEs of 20 ms and 100 ms. The values were evaluated on a pixel‐by‐pixel basis using custom‐built software on a DEC alpha workstation and converted to dose using calibration data. Depth doses and isodose lines of the Ru‐106 eye‐plaque were generated. It is concluded that the BANG gel dosimetry offers the potential for measuring the 3D dose distributions of an ophthalmologic applicator, with high spatial resolution and relatively good accuracy.PACS number(s): 87.66.–a, 87.90.+y
- 1 March 2001
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 2 (2) , 85-89
Open AccessThe measurement of three dimensional dose distribution of a ruthenium‐106 ophthalmological applicator using magnetic resonance imaging of BANG polymer gels1
The BANG (MGS Research Inc., Guilford, CT) polymer gel has been used as a dosimeter to determine the three‐dimensional (3D) dose distribution of a ruthenium‐106 (Ru‐106) ophthalmologic applicator. An eye phantom made of the BANG gel was irradiated with the Ru‐106 source for up to 1 h. The phantom and a set of calibration vials were scanned simultaneously in a GE 1.5 T MR imager using the Hahn spin‐echo pulse sequence with a TR of 2000 ms and two TEs of 20 ms and 100 ms. The values were evaluated on a pixel‐by‐pixel basis using custom‐built software on a DEC alpha workstation and converted to dose using calibration data. Depth doses and isodose lines of the Ru‐106 eye‐plaque were generated. It is concluded that the BANG gel dosimetry offers the potential for measuring the 3D dose distributions of an ophthalmologic applicator, with high spatial resolution and relatively good accuracy.PACS number(s): 87.66.–a, 87.90.+y
- 4 June 1995
- Published by Wiley in Medical Physics
- Vol. 22 (6) , 781-792
Beam characteristics of a new generation 50 MeV racetrack microtron
The first of a new generation of microtron accelerators has been installed and tested. It is currently in use for multisegment conformal radiotherapy at our institution. The unit produces x rays and electrons from 10 to 50 MeV in 5 MeV increments. It incorporates a 64 leaf, doubly focused multileaf collimator (MLC), which can be used to shape x-ray and electron beams. Both x-ray and electron beams are produced by magnetically scanning the electron beams from the accelerator. The new generation unit incorporates a purging magnet to sweep away any primary or secondary electrons that pass through the target(s). In this paper, the beam characteristics of the accelerator that were studied during acceptance testing are described. Representative examples of depth doses, beam profiles, output factors, and elementary beam distributions are presented and discussed, in comparison with the earlier generation of microtron accelerators and with other radiotherapy machines.
- 4 June 1995
- Published by Wiley in Medical Physics
- Vol. 22 (6) , 781-792
Beam characteristics of a new generation 50 MeV racetrack microtron
The first of a new generation of microtron accelerators has been installed and tested. It is currently in use for multisegment conformal radiotherapy at our institution. The unit produces x rays and electrons from 10 to 50 MeV in 5 MeV increments. It incorporates a 64 leaf, doubly focused multileaf collimator (MLC), which can be used to shape x-ray and electron beams. Both x-ray and electron beams are produced by magnetically scanning the electron beams from the accelerator. The new generation unit incorporates a purging magnet to sweep away any primary or secondary electrons that pass through the target(s). In this paper, the beam characteristics of the accelerator that were studied during acceptance testing are described. Representative examples of depth doses, beam profiles, output factors, and elementary beam distributions are presented and discussed, in comparison with the earlier generation of microtron accelerators and with other radiotherapy machines.