Albert Y. C. Fung
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Albert Y. C. Fung has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Marco Zaider
Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, NY
2 shared publications - Chen‐Shou Chui
Department of Medical Physics, Memorial Sloan-Kettering Cancer Center, New York, New York 10021, USA
1 shared publication David A Silvern
Department of Oncology, Rabin Medical Center, Petah-Tikva, Israel
1 shared publication- David Harold Abramson
Ophthalmic Oncology, Memorial Sloan Kettering Cancer Center, New York, New York, USA
1 shared publication - Howard Ira Amols
Memorial Sloan-Kettering Cancer Center, New York, New York 10021, USA
1 shared publication - James R. Wong
Department of Radiation Oncology Morristown Memorial Hospital 100 Madison Avenue Morristown New Jersey 07962
1 shared publication
Latest Publications
- Open Access
- 1 March 2003
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 4 (2) , 112-119
Computed tomography localization of radiation treatment delivery versus conventional localization with bony landmarks
A computed tomography (CT) scanner was installed in the linear accelerator room (Primatom) at Morristown. Since June 2000, we have been providing prostate, lung, and liver cancer patients with fusion of CT and linac radiation treatment. This paper describes our registration methods between planning and treatment CT images, and compares treatment localization by CT versus conventional localization by bony landmarks such as portal imaging. For image registration, we printed out beforehand the beam's eye view of the treatment fields. Prostate tumor volume from each Primatom CT slice was mapped on the printouts, and the necessary isocenter shift relative to the skin marks was deduced. No port film was necessary for our Primatom patients. For ten patients we generated digitally‐reconstructed radiographs (DRRs) with bone contrast from the CT scans, and deduced the required shift as the difference between the DRRs of the Primatom CT versus the planning CT This represented the best observable shift should portal imaging be employed. Shift from bony landmark significantly correlated with the Primatom CT shift. Positioning adjustment based on bony anatomy was generally in the same direction as the CT shift for individual patient, but frequently did not go far enough. Our study confirmed that prostate organ motion relative to the bones has an average length of 4.7 mm (with standard deviation of 2.7 mm), and indicated the superiority of CT versus conventional bony structure (such as portal imaging) localization.PACS number(s): 87.53.Kn, 87.53.–j
- 1 March 2003
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 4 (2) , 112-119
Open AccessComputed tomography localization of radiation treatment delivery versus conventional localization with bony landmarks
A computed tomography (CT) scanner was installed in the linear accelerator room (Primatom) at Morristown. Since June 2000, we have been providing prostate, lung, and liver cancer patients with fusion of CT and linac radiation treatment. This paper describes our registration methods between planning and treatment CT images, and compares treatment localization by CT versus conventional localization by bony landmarks such as portal imaging. For image registration, we printed out beforehand the beam's eye view of the treatment fields. Prostate tumor volume from each Primatom CT slice was mapped on the printouts, and the necessary isocenter shift relative to the skin marks was deduced. No port film was necessary for our Primatom patients. For ten patients we generated digitally‐reconstructed radiographs (DRRs) with bone contrast from the CT scans, and deduced the required shift as the difference between the DRRs of the Primatom CT versus the planning CT This represented the best observable shift should portal imaging be employed. Shift from bony landmark significantly correlated with the Primatom CT shift. Positioning adjustment based on bony anatomy was generally in the same direction as the CT shift for individual patient, but frequently did not go far enough. Our study confirmed that prostate organ motion relative to the bones has an average length of 4.7 mm (with standard deviation of 2.7 mm), and indicated the superiority of CT versus conventional bony structure (such as portal imaging) localization.PACS number(s): 87.53.Kn, 87.53.–j
- Open Access
- 1 March 2001
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 2 (2) , 85-89
The measurement of three dimensional dose distribution of a ruthenium‐106 ophthalmological applicator using magnetic resonance imaging of BANG polymer gels1
The BANG (MGS Research Inc., Guilford, CT) polymer gel has been used as a dosimeter to determine the three‐dimensional (3D) dose distribution of a ruthenium‐106 (Ru‐106) ophthalmologic applicator. An eye phantom made of the BANG gel was irradiated with the Ru‐106 source for up to 1 h. The phantom and a set of calibration vials were scanned simultaneously in a GE 1.5 T MR imager using the Hahn spin‐echo pulse sequence with a TR of 2000 ms and two TEs of 20 ms and 100 ms. The values were evaluated on a pixel‐by‐pixel basis using custom‐built software on a DEC alpha workstation and converted to dose using calibration data. Depth doses and isodose lines of the Ru‐106 eye‐plaque were generated. It is concluded that the BANG gel dosimetry offers the potential for measuring the 3D dose distributions of an ophthalmologic applicator, with high spatial resolution and relatively good accuracy.PACS number(s): 87.66.–a, 87.90.+y
- 1 March 2001
- Published by Wiley in Journal of Applied Clinical Medical Physics
- Vol. 2 (2) , 85-89
Open AccessThe measurement of three dimensional dose distribution of a ruthenium‐106 ophthalmological applicator using magnetic resonance imaging of BANG polymer gels1
The BANG (MGS Research Inc., Guilford, CT) polymer gel has been used as a dosimeter to determine the three‐dimensional (3D) dose distribution of a ruthenium‐106 (Ru‐106) ophthalmologic applicator. An eye phantom made of the BANG gel was irradiated with the Ru‐106 source for up to 1 h. The phantom and a set of calibration vials were scanned simultaneously in a GE 1.5 T MR imager using the Hahn spin‐echo pulse sequence with a TR of 2000 ms and two TEs of 20 ms and 100 ms. The values were evaluated on a pixel‐by‐pixel basis using custom‐built software on a DEC alpha workstation and converted to dose using calibration data. Depth doses and isodose lines of the Ru‐106 eye‐plaque were generated. It is concluded that the BANG gel dosimetry offers the potential for measuring the 3D dose distributions of an ophthalmologic applicator, with high spatial resolution and relatively good accuracy.PACS number(s): 87.66.–a, 87.90.+y
- 1 July 2000
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 47 (5) , 1385-1395
Treatment-plan optimization for soft-tissue sarcoma brachytherapy using a genetic algorithm
- 1 July 2000
- Published by Elsevier in International Journal of Radiation Oncology - Biology - Physics (IJROBP)
- Vol. 47 (5) , 1385-1395
Treatment-plan optimization for soft-tissue sarcoma brachytherapy using a genetic algorithm